RD17AZ36AJ3N
RD17AZ36AJ3N is in the certified data.
Its certified full-speed heating output at 5°F is 17,800–29,800 Btu/h5.22–8.73 kW, 49–83% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Friedrich, Rheem + 3 more · central heat pump
All 121 certified Friedrich models · All 91 certified Rheem models · All 47 certified Russell models · All 89 certified Ruud models · All 51 certified Sure models
RD17AZ36AJ3N is in the certified data as of Sep 19, 2026. RD17AZ36AJ3N changed its certified heat output at 47°F on 72 pairings from 34,200 Btu/h to 36,000 Btu/h in the certified data between September 2024 and September 2026.
- 36,000 Btu (3-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
36,00010.55NR
No 47°F rating for this pairing.
31,2009.14NR at 17°F
29,4008.62NR at 5°F
Btu/hkW, certified
1.90NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 36,000 Btu/h10.55 kW of heat at 47°F, 31,200 Btu/h9.14 kW at 17°F, and 29,400 Btu/h8.62 kW at 5°F, 82% of its 47°F rating. It delivers 34,200 Btu/h10.02 kW of cooling at 95°F. At 5°F that is 2,900 Btu/h0.85 kW above the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 21,200 Btu/h6.21 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214066466 · listed by Rheem · certified Jun 3, 2026 · 15 pairings share these values
Rebates where you live
Meets the recorded equipment thresholds of 58 programs in 36 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Colorado (2), Connecticut (1), Delaware (2), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (1), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (2), New Jersey (7), New York (4), North Carolina (1), Oregon (2), Pennsylvania (3), Rhode Island (1), South Carolina (1), Tennessee (1), Texas (3), Utah (1), Vermont (3), Washington (3), Wisconsin (1), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 58 programs by state and province
Alabama
Arizona
California
Colorado
Connecticut
Delaware
- Delaware Electric Cooperative High Efficiency Heat Pump Grant
- Energize Delaware Home Performance · Delmarva Power · Delaware Electric Cooperative · Delaware Municipal Electric Corporation · City of Dover · Chesapeake Utilities
Idaho
Illinois
Kansas
Kentucky
Maryland
- BGE Smart Energy Savers Heating and Cooling
- Delmarva Power Maryland HVAC Efficiency Program
- Pepco Maryland HVAC Efficiency Program
Massachusetts
Michigan
Minnesota
- Save Energy Minnesota
- Wright-Hennepin Air Source Heat Pump Rebate · Wright-Hennepin Cooperative Electric Association
- Xcel Energy Minnesota Air Source Heat Pump Rebates
Mississippi
- EnergyRight Home Energy Rebates · TVA EnergyRight · EPB
- Entergy Mississippi Residential Heating and Cooling
Nevada
New Hampshire
New Jersey
- Atlantic City Electric Building Decarbonization
- Atlantic City Electric HVAC Efficiency Program
- JCP&L Residential HVAC Rebates
- PSE&G HVAC Instant Rebates
- PSE&G Residential Building Decarbonization
- Rockland Electric Clean Heat
- SAVEGREEN Hybrid Heat · New Jersey Natural Gas
New York
- EmPower+
- NYS Clean Heat: Central Hudson, NYSEG, RG&E, and O&R · Orange & Rockland
- NYS Clean Heat: Con Edison
- NYS Clean Heat: National Grid
North Carolina
Oregon
- Energy Trust of Oregon Heat Pump Incentives · Portland General Electric (PGE) · Pacific Power
- Idaho Power Heating and Cooling Efficiency Program
Pennsylvania
Rhode Island
South Carolina
Tennessee
Texas
- Austin Energy Air Conditioning and Heat Pump Rebate
- CPS Energy SaveNow HVAC Rebate
- CenterPoint Residential Standard Offer Program · CenterPoint Energy
Utah
Vermont
- Burlington Electric Heat Pump Rebates · Burlington Electric Department
- Efficiency Vermont Heat Pump Discounts
- Green Mountain Power Income-Eligible Heat Pump Rebate
Washington
- Avista Heat Pump Rebates
- PSE Gas-to-Heat-Pump Conversion Rebate · Puget Sound Energy
- Seattle City Light Heat Pump Rebates
Wisconsin
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 29,4008.62 kW | +11% | 1.90 | |
| 17°Ffull speed | 31,2009.14 kW | +19% | NR | |
| 47°Fnormal speed | 36,00010.55 kW | +2% | NR | |
| 95°Fcooling, full load | 34,20010.02 kW | — | NR |
EER2 10.0 in that test. SEER2 18.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.53kW
- Electrical input in the 95°F cooling test
- 3.42kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 29,400 Btu/h8.62 kWNR
- This unit at 5°F median across its pairings
- 29,400 Btu/h8.62 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 63% of them, at number 169 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Among 36,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 166th of 451; HSPF2, 313th of 467 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- FOP1836MJAZCA: The same 36,000 Btu/h rating at 47°F; 43,000 Btu/h at 5°F (this model: 29,400).
- AHU3G-36HFN-B: The same 36,000 Btu/h rating at 47°F; 32,600 Btu/h at 5°F (this model: 29,400).
- MOE30-36HFN10-M3X: The same 36,000 Btu/h rating at 47°F; 36,000 Btu/h at 5°F (this model: 29,400).
Closest models by heat at 5°F
- THH48HAI2NAF2U23TCL · 30,000 Btu/h
- MOD30-36HFN8-M3MDV · 29,800 Btu/h
- FOP1936MJAYCAFujitsu · 29,400 Btu/h
- RP19AY36AJVCRheem · 29,400 Btu/h
- D5CURAH36AAKAirquest, Arcoaire + 15 more · 29,200 Btu/h
- DZ6VSA361EADaikin · 29,000 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 29,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 700–1,230 |
| Mild | Typical | 16–26 | 1,130–1,840 |
| Mild | Tight, well insulated | 10–18 | 1,630–2,940 |
| Cold | Drafty, little insulation | 28–52 | 570–1,050 |
| Cold | Typical | 18–30 | 980–1,630 |
| Cold | Tight, well insulated | 12–22 | 1,340–2,450 |
| Very cold | Drafty, little insulation | 32–58 | 510–920 |
| Very cold | Typical | 22–38 | 770–1,340 |
| Very cold | Tight, well insulated | 16–28 | 1,050–1,840 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for RD17AZ36AJ3N
201 pairings · 201 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| Heat output at 17°F full speed | 31,200 Btu/h9.14 kWNR | 22,800–31,600 Btu/h6.68–9.26 kW |
| Heat output at 5°F full speed | 29,400 Btu/h8.62 kWNR | 17,800–29,800 Btu/h5.22–8.73 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 82%NR | |
| COP at 5°F full speed | 1.90NR | 1.90–2.30 |
| HSPF2 Region IV | 8.1NR | 8.1–8.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 34,200 Btu/h10.02 kWNR | 34,200 Btu/h10.02 kW |
| EER2 at 95°F | 10.0NR | 10.0–12.0 |
| SEER2 cooling season | 18.0NR | 17.0–19.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | RCFZ3621MTANM | 32 indoor units |
| Furnace | R97MV1005A21DHS | 92 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | RD17AZ36AJ3N | |
Across 201 certified pairings with 32 indoor models: heat at 5°F 17,800 Btu/h with FRH2TZ3621MTANN to 29,800 Btu/h with RCFZ3621MTANM; HSPF2 8.1 with FRH2TZ3621MTANA to 8.5 with FRH2TZ3617STANN; SEER2 17.0 with RCFZ3621MTANM to 19.0 with FRH2VZ3621MTANA. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
32 indoor units · 201 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 6 indoor units
-
TCFZ3621MTANM (the pairing on screen) brand not stated 29,600 Btu/h8.67 kWat 5°F, full speed
-
RCFZ3621MTANM (the pairing on screen) brand not stated 29,600 Btu/h8.67 kWat 5°F, full speed
-
RCFZ3621MTAAM (the pairing on screen) brand not stated 18,200 Btu/h5.33 kWat 5°F, full speed
-
TCFZ3621MTAAM (the pairing on screen) brand not stated 18,300 Btu/h5.36 kWat 5°F, full speed
-
TCFZ3624MTANM (the pairing on screen) brand not stated 18,100 Btu/h5.30 kWat 5°F, full speed
-
RCFZ3624MTANM (the pairing on screen) brand not stated 18,100 Btu/h5.30 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| TCFZ3621MTANM (the pairing on screen) | — | 29,6008.67 | 36,00010.55 | 34,20010.02 | 82% | 1.90 | Yes | 81 |
| RCFZ3621MTANM (the pairing on screen) | — | 29,6008.67 | 36,00010.55 | 34,20010.02 | 82% | 1.90 | Yes | 54 |
| RCFZ3621MTAAM (the pairing on screen) | — | 18,2005.33 | 36,00010.55 | 34,20010.02 | 51% | 2.30 | Yes | 8 |
| TCFZ3621MTAAM (the pairing on screen) | — | 18,3005.36 | 36,00010.55 | 34,20010.02 | 51% | 2.30 | Yes | 8 |
| TCFZ3624MTANM (the pairing on screen) | — | 18,1005.30 | 36,00010.55 | 34,20010.02 | 50% | 2.30 | Yes | 4 |
| RCFZ3624MTANM (the pairing on screen) | — | 18,1005.30 | 36,00010.55 | 34,20010.02 | 50% | 2.30 | Yes | 3 |
Air handler · 4 indoor units
-
RH2TZ3617STANN (the pairing on screen) brand not stated 18,100 Btu/h5.30 kWat 5°F, full speed
-
RH2TZ3621MTANA (the pairing on screen) brand not stated 18,000 Btu/h5.28 kWat 5°F, full speed
-
RH2VZ3617STANN (the pairing on screen) brand not stated 18,100 Btu/h5.30 kWat 5°F, full speed
-
RH2VZ3621MTANA (the pairing on screen) brand not stated 18,000 Btu/h5.28 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| RH2TZ3617STANN (the pairing on screen) | — | 18,1005.30 | 36,00010.55 | 34,20010.02 | 50% | 2.30 | Yes | 2 |
| RH2TZ3621MTANA (the pairing on screen) | — | 18,0005.28 | 36,00010.55 | 34,20010.02 | 50% | 2.30 | Yes | 2 |
| RH2VZ3617STANN (the pairing on screen) | — | 18,1005.30 | 36,00010.55 | 34,20010.02 | 50% | 2.30 | Yes | 2 |
| RH2VZ3621MTANA (the pairing on screen) | — | 18,0005.28 | 36,00010.55 | 34,20010.02 | 50% | 2.30 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Friedrich and Rheem heat pumps the same?43 shared model numbers
- Are Friedrich and Ruud heat pumps the same?43 shared model numbers
- Are Friedrich and Russell heat pumps the same?25 shared model numbers
- Are Friedrich and Sure heat pumps the same?25 shared model numbers
- Are Rheem and Ruud heat pumps the same?85 shared model numbers
- Are Rheem and Russell heat pumps the same?25 shared model numbers
- Are Rheem and Sure heat pumps the same?25 shared model numbers
Model number as listed
- RD17AZ36AJ3N 201 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- RD17AZ36AJ3N changed its certified heat output at 47°F on 72 pairings from 34,200 Btu/h to 36,000 Btu/h in the certified data between September 2024 and September 2026.
- RD17AZ36AJ3N changed its certified heat output at 47°F on 20 pairings from 34,200 Btu/h to 36,000 Btu/h in the certified data between November 2024 and September 2026.
- RD17AZ36AJ3N changed its certified heat output at 47°F on AHRI certificate 214066503 from 34,200 Btu/h to 36,000 Btu/h in the certified data between August 2025 and September 2026.
- RD17AZ36AJ3N changed its certified heat output at 47°F on 146 pairings from 34,200 Btu/h to 36,000 Btu/h in the certified data between March 2025 and May 2025.
- RD17AZ36AJ3N was in the certified data by September 2024.
History and definitions
Other F Series models by nominal cooling size: RD17AZ24AJ3N (24,000 Btu), FWP14AY42AJ2N (42,000 Btu), RD17AZ48AJ3N (48,000 Btu), FRP14AY60AJ2N (54,000 Btu), FWP14AY60AJ2N (54,000 Btu), RD17AZ60AJ3N (54,000 Btu).
Other CLASSIC PLUS models by nominal cooling size: RP15AY18AJ2N (18,000 Btu), RP15AZ18AJ2N (18,000 Btu), WP15AZ18AJ2N (18,000 Btu), RD16AY24AJVC (24,000 Btu), RP15AZ24AJ2N (24,000 Btu), WP15AZ24AJ2N (24,000 Btu), RD16AY36AJVC (30,000 Btu), RP15AZ30AJ2N (30,000 Btu); more models from this brand.
Other PRESTIGE SERIES models by nominal cooling size: RD18AY24AJVC (18,000 Btu), RD17AZ24AJ3N (24,000 Btu), RP18AZ24AJVC (24,000 Btu), RP19AY24AJVC (24,000 Btu), RD18AY36AJVC (30,000 Btu), RP18AZ36AJVC (36,000 Btu), RP19AY36AJVC (36,000 Btu), RD18AY48AJVC (42,000 Btu); more models from this brand.
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 3, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read