RD17AZ36AJ3N is in the certified data.

Its certified full-speed heating output at 5°F is 17,800–29,800 Btu/h, 49–83% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Friedrich, Rheem + 3 more · central heat pump

All 121 certified Friedrich models · All 91 certified Rheem models · All 47 certified Russell models · All 89 certified Ruud models · All 51 certified Sure models

RD17AZ36AJ3N is in the certified data as of Sep 19, 2026. RD17AZ36AJ3N changed its certified heat output at 47°F on 72 pairings from 34,200 Btu/h to 36,000 Btu/h in the certified data between September 2024 and September 2026.

201 certified pairings with 21 different figures. See all

Certified heating and cooling

Heating at 47°F

36,000

31,200 at 17°F

29,400 at 5°F

Btu/h, certified

1.90 COP at 5°F

Cooling at 95°F

34,200

Btu/h, certified

EER2 10.0 at 95°F

SEER2 18.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for RD17AZ36AJ3N, by outdoor temperature Heating: 29,400 Btu/h at 5°F, 31,200 Btu/h at 17°F, 36,000 Btu/h at 47°F. Cooling: 34,200 Btu/h at 95°F. The bars start at zero. Median of 3-ton central models: 26,400 Btu/h at 5°F, 26,200 Btu/h at 17°F, 35,200 Btu/h at 47°F, 35,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 29,400 5°F 31,200 17°F 36,000 47°F 34,200 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 36,000 Btu/h of heat at 47°F, 31,200 Btu/h at 17°F, and 29,400 Btu/h at 5°F, 82% of its 47°F rating. It delivers 34,200 Btu/h of cooling at 95°F. At 5°F that is 2,900 Btu/h above the example heating load of 26,500 Btu/h; at 95°F it is 21,200 Btu/h above the example cooling load of 13,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214066466 · listed by Rheem · certified Jun 3, 2026 · 15 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 58 programs in 36 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Colorado (2), Connecticut (1), Delaware (2), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (1), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (2), New Jersey (7), New York (4), North Carolina (1), Oregon (2), Pennsylvania (3), Rhode Island (1), South Carolina (1), Tennessee (1), Texas (3), Utah (1), Vermont (3), Washington (3), Wisconsin (1), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 58 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Delaware

Idaho

Illinois

Kansas

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 29,4008.62 kW +11% 1.90
17°Ffull speed 31,2009.14 kW +19% NR
47°Fnormal speed 36,00010.55 kW +2% NR
95°Fcooling, full load 34,20010.02 kW — NR

EER2 10.0 in that test. SEER2 18.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
4.53kW
Electrical input in the 95°F cooling test
3.42kW
Seasonal average heating COP
2.37

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton central models

This pairing at 5°F
29,400 Btu/h
This unit at 5°F median across its pairings
29,400 Btu/h
Median of 3-ton central models at 5°F
26,400 Btu/h
Models in this group
451

This unit is above 63% of them, at number 169 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 36,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 166th of 451; HSPF2, 313th of 467 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • FOP1836MJAZCA: The same 36,000 Btu/h rating at 47°F; 43,000 Btu/h at 5°F (this model: 29,400).
  • AHU3G-36HFN-B: The same 36,000 Btu/h rating at 47°F; 32,600 Btu/h at 5°F (this model: 29,400).
  • MOE30-36HFN10-M3X: The same 36,000 Btu/h rating at 47°F; 36,000 Btu/h at 5°F (this model: 29,400).

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 29,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42700–1,230
MildTypical16–261,130–1,840
MildTight, well insulated10–181,630–2,940
ColdDrafty, little insulation28–52570–1,050
ColdTypical18–30980–1,630
ColdTight, well insulated12–221,340–2,450
Very coldDrafty, little insulation32–58510–920
Very coldTypical22–38770–1,340
Very coldTight, well insulated16–281,050–1,840

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for RD17AZ36AJ3N

201 pairings · 201 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for RD17AZ36AJ3N
This pairingAll pairings
Heating
Heat output at 47°F normal speed 36,000 Btu/h 36,000 Btu/h
Heat output at 17°F full speed 31,200 Btu/h 22,800–31,600 Btu/h
Heat output at 5°F full speed 29,400 Btu/h 17,800–29,800 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 82%
COP at 5°F full speed 1.90 1.90–2.30
HSPF2 Region IV 8.1 8.1–8.5
Cooling
Cooling capacity at 95°F full-load test 34,200 Btu/h 34,200 Btu/h
EER2 at 95°F 10.0 10.0–12.0
SEER2 cooling season 18.0 17.0–19.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit RCFZ3621MTANM 32 indoor units
FurnaceR97MV1005A21DHS 92 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified RD17AZ36AJ3N

Across 201 certified pairings with 32 indoor models: heat at 5°F 17,800 Btu/h with FRH2TZ3621MTANN to 29,800 Btu/h with RCFZ3621MTANM; HSPF2 8.1 with FRH2TZ3621MTANA to 8.5 with FRH2TZ3617STANN; SEER2 17.0 with RCFZ3621MTANM to 19.0 with FRH2VZ3621MTANA. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

32 indoor units · 201 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 6 indoor units

  1. TCFZ3621MTANM brand not stated 29,600 Btu/hat 5°F, full speed

    81 pairings, 54 with a furnace · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 82% · COP 1.90

  2. RCFZ3621MTANM (the pairing on screen) brand not stated 29,600 Btu/hat 5°F, full speed

    54 pairings, 35 with a furnace · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 82% · COP 1.90

  3. RCFZ3621MTAAM brand not stated 18,200 Btu/hat 5°F, full speed

    8 pairings, 7 with a furnace · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 51% · COP 2.30

  4. TCFZ3621MTAAM brand not stated 18,300 Btu/hat 5°F, full speed

    8 pairings, 5 with a furnace · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 51% · COP 2.30

  5. TCFZ3624MTANM brand not stated 18,100 Btu/hat 5°F, full speed

    4 pairings, 4 with a furnace · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 50% · COP 2.30

  6. RCFZ3624MTANM brand not stated 18,100 Btu/hat 5°F, full speed

    3 pairings, 3 with a furnace · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 50% · COP 2.30

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
TCFZ3621MTANM — 29,600 36,000 34,200 82% 1.90 Yes 81
RCFZ3621MTANM (the pairing on screen) — 29,600 36,000 34,200 82% 1.90 Yes 54
RCFZ3621MTAAM — 18,200 36,000 34,200 51% 2.30 Yes 8
TCFZ3621MTAAM — 18,300 36,000 34,200 51% 2.30 Yes 8
TCFZ3624MTANM — 18,100 36,000 34,200 50% 2.30 Yes 4
RCFZ3624MTANM — 18,100 36,000 34,200 50% 2.30 Yes 3

Air handler · 4 indoor units

  1. RH2TZ3617STANN brand not stated 18,100 Btu/hat 5°F, full speed

    2 pairings · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 50% · COP 2.30

  2. RH2TZ3621MTANA brand not stated 18,000 Btu/hat 5°F, full speed

    2 pairings · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 50% · COP 2.30

  3. RH2VZ3617STANN brand not stated 18,100 Btu/hat 5°F, full speed

    2 pairings · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 50% · COP 2.30

  4. RH2VZ3621MTANA brand not stated 18,000 Btu/hat 5°F, full speed

    2 pairings · 47°F 36,000 Btu/h · 95°F cooling 34,200 Btu/h · Cold output 50% · COP 2.30

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RH2TZ3617STANN — 18,100 36,000 34,200 50% 2.30 Yes 2
RH2TZ3621MTANA — 18,000 36,000 34,200 50% 2.30 Yes 2
RH2VZ3617STANN — 18,100 36,000 34,200 50% 2.30 Yes 2
RH2VZ3621MTANA — 18,000 36,000 34,200 50% 2.30 Yes 2

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 32 indoor units All 201 certified pairings

Sold as, and units with identical certified values

Product history

  • RD17AZ36AJ3N changed its certified heat output at 47°F on 72 pairings from 34,200 Btu/h to 36,000 Btu/h in the certified data between September 2024 and September 2026.
  • RD17AZ36AJ3N changed its certified heat output at 47°F on 20 pairings from 34,200 Btu/h to 36,000 Btu/h in the certified data between November 2024 and September 2026.
  • RD17AZ36AJ3N changed its certified heat output at 47°F on AHRI certificate 214066503 from 34,200 Btu/h to 36,000 Btu/h in the certified data between August 2025 and September 2026.
  • RD17AZ36AJ3N changed its certified heat output at 47°F on 146 pairings from 34,200 Btu/h to 36,000 Btu/h in the certified data between March 2025 and May 2025.
  • RD17AZ36AJ3N was in the certified data by September 2024.

History and definitions

Other F Series models by nominal cooling size: RD17AZ24AJ3N (24,000 Btu), FWP14AY42AJ2N (42,000 Btu), RD17AZ48AJ3N (48,000 Btu), FRP14AY60AJ2N (54,000 Btu), FWP14AY60AJ2N (54,000 Btu), RD17AZ60AJ3N (54,000 Btu).

Other CLASSIC PLUS models by nominal cooling size: RP15AY18AJ2N (18,000 Btu), RP15AZ18AJ2N (18,000 Btu), WP15AZ18AJ2N (18,000 Btu), RD16AY24AJVC (24,000 Btu), RP15AZ24AJ2N (24,000 Btu), WP15AZ24AJ2N (24,000 Btu), RD16AY36AJVC (30,000 Btu), RP15AZ30AJ2N (30,000 Btu); more models from this brand.

Other PRESTIGE SERIES models by nominal cooling size: RD18AY24AJVC (18,000 Btu), RD17AZ24AJ3N (24,000 Btu), RP18AZ24AJVC (24,000 Btu), RP19AY24AJVC (24,000 Btu), RD18AY36AJVC (30,000 Btu), RP18AZ36AJVC (36,000 Btu), RP19AY36AJVC (36,000 Btu), RD18AY48AJVC (42,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Jun 3, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “RD17AZ36AJ3N — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/rd17az36aj3n