RD18AY24AJVC is in the certified data.

Its certified full-speed heating output at 5°F is 16,800–18,400 Btu/h, 71–88% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Friedrich, Rheem + 3 more · central heat pump

All 121 certified Friedrich models · All 91 certified Rheem models · All 47 certified Russell models · All 89 certified Ruud models · All 51 certified Sure models

RD18AY24AJVC is in the certified data as of Sep 19, 2026. RD18AY24AJVC changed its certified heat output at 47°F on 262 pairings in the certified data between August 2025 and September 2026. The new figure is lower on all 262.

399 certified pairings with 30 different figures. See all

Certified heating and cooling

Heating at 47°F

20,800

18,200 at 17°F

17,000 at 5°F

Btu/h, certified

1.90 COP at 5°F

Cooling at 95°F

21,000

Btu/h, certified

EER2 11.0 at 95°F

SEER2 18.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for RD18AY24AJVC, by outdoor temperature Heating: 17,000 Btu/h at 5°F, 18,200 Btu/h at 17°F, 20,800 Btu/h at 47°F. Cooling: 21,000 Btu/h at 95°F. The bars start at zero. Median of 1.5-ton central models: 11,200 Btu/h at 5°F, 12,600 Btu/h at 17°F, 18,000 Btu/h at 47°F, 18,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 17,000 5°F 18,200 17°F 20,800 47°F 21,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 1.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 20,800 Btu/h of heat at 47°F, 18,200 Btu/h at 17°F, and 17,000 Btu/h at 5°F, 82% of its 47°F rating. It delivers 21,000 Btu/h of cooling at 95°F. At 5°F that is 6,000 Btu/h above the example heating load of 11,000 Btu/h; at 95°F it is 15,500 Btu/h above the example cooling load of 5,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 216819024 · listed by Friedrich · certified Oct 27, 2025 · 30 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 63 programs in 38 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (1), Connecticut (3), Delaware (1), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maine (2), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (3), New York (4), North Carolina (1), Oregon (2), Pennsylvania (2), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (2), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 63 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Delaware

Idaho

Illinois

Kansas

Kentucky

Maine

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 1.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 17,0004.98 kW +52% 1.90
17°Ffull speed 18,2005.33 kW +44% NR
47°Fnormal speed 20,8006.10 kW +16% NR
95°Fcooling, full load 21,0006.15 kW — NR

EER2 11.0 in that test. SEER2 18.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.62kW
Electrical input in the 95°F cooling test
1.91kW
Seasonal average heating COP
2.78

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 18,000 Btu heat pumps

1.5-ton central models

This pairing at 5°F
17,000 Btu/h
This unit at 5°F median across its pairings
17,000 Btu/h
Median of 1.5-ton central models at 5°F
11,200 Btu/h
Models in this group
243

This unit is above 71% of them, at number 71 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 18,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 95th of 243; HSPF2, 32nd of 254 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • GHO18H52ACXL05: 22,000 Btu/h at 47°F (this model: 21,000); 20,400 Btu/h at 5°F (this model: 17,000).
  • 5HPL5024A1: 22,000 Btu/h at 47°F (this model: 21,000); 19,000 Btu/h at 5°F (this model: 17,000).
  • E4HL5018A1000A: 20,000 Btu/h at 47°F (this model: 21,000); HSPF2 8.5 (this model: 9.5).

Closest models by heat at 5°F

Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 17,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42400–710
MildTypical16–26650–1,060
MildTight, well insulated10–18940–1,700
ColdDrafty, little insulation28–52330–610
ColdTypical18–30570–940
ColdTight, well insulated12–22770–1,420
Very coldDrafty, little insulation32–58290–530
Very coldTypical22–38450–770
Very coldTight, well insulated16–28610–1,060

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for RD18AY24AJVC

399 pairings · 399 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for RD18AY24AJVC
This pairingAll pairings
Heating
Heat output at 47°F normal speed 20,800 Btu/h 20,600–24,000 Btu/h
Heat output at 17°F full speed 18,200 Btu/h 17,900–19,800 Btu/h
Heat output at 5°F full speed 17,000 Btu/h 16,800–18,400 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 82%
COP at 5°F full speed 1.90 1.90–2.00
HSPF2 Region IV 9.5 8.1–10.0
Cooling
Cooling capacity at 95°F full-load test 21,000 Btu/h 20,800–21,400 Btu/h
EER2 at 95°F 11.0 10.0–12.0
SEER2 cooling season 18.0 17.0–19.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit RCFY2417MTANM 19 indoor units
FurnaceFR801V0503A14UH 103 furnaces
Cold-climate designation EPA's designation, as published Yes On some pairings
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold United States US and Canada
Model string as certified RD18AY24AJVC

Across 399 certified pairings with 19 indoor models: heat at 5°F 16,800 Btu/h with FRHMVY2421MEACN to 18,400 Btu/h with RCFY2417STANM; HSPF2 8.1 with RCFY2417MTANM to 10.0 with FRH2TY2417STANN; SEER2 17.0 with RCFY2417MTANM to 19.0 with FRHMVY2421MEACN. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

19 indoor units · 399 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 6 indoor units

  1. RCFY2417STANM brand not stated 18,200 Btu/hat 5°F, full speed

    73 pairings, 53 with a furnace · 47°F 21,000 Btu/h · 95°F cooling 21,000 Btu/h · Cold output 87% · COP 2.00

  2. RCFY2421MTANM brand not stated 17,000 Btu/hat 5°F, full speed

    69 pairings, 54 with a furnace · 47°F 20,800 Btu/h · 95°F cooling 21,000 Btu/h · Cold output 81% · COP 1.90

  3. TCFY2421MTANM brand not stated 17,000 Btu/hat 5°F, full speed

    69 pairings, 46 with a furnace · 47°F 20,800 Btu/h · 95°F cooling 21,000 Btu/h · Cold output 81% · COP 1.90

  4. RCFY2417MTANM (the pairing on screen) brand not stated 17,000 Btu/hat 5°F, full speed

    66 pairings, 48 with a furnace · 47°F 20,900 Btu/h · 95°F cooling 21,000 Btu/h · Cold output 81% · COP 1.90

  5. TCFY2417MTANM brand not stated 17,000 Btu/hat 5°F, full speed

    66 pairings, 44 with a furnace · 47°F 20,900 Btu/h · 95°F cooling 21,000 Btu/h · Cold output 81% · COP 1.90

  6. TCFY2417STANM brand not stated 18,200 Btu/hat 5°F, full speed

    26 pairings, 25 with a furnace · 47°F 21,000 Btu/h · 95°F cooling 21,000 Btu/h · Cold output 87% · COP 2.00

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RCFY2417STANM — 18,200 21,000 21,000 87% 2.00 Yes 73
RCFY2421MTANM — 17,000 20,800 21,000 81% 1.90 Yes 69
TCFY2421MTANM — 17,000 20,800 21,000 81% 1.90 Yes 69
RCFY2417MTANM (the pairing on screen) — 17,000 20,900 21,000 81% 1.90 Yes 66
TCFY2417MTANM — 17,000 20,900 21,000 81% 1.90 Yes 66
TCFY2417STANM — 18,200 21,000 21,000 87% 2.00 Yes 26

Air handler · 4 indoor units

  1. RH2VY3617STACN brand not stated 17,000 Btu/hat 5°F, full speed

    5 pairings · 47°F 20,600 Btu/h · 95°F cooling 21,200 Btu/h · Cold output 83% · COP 2.00

  2. RF2TY2421STANS brand not stated 17,000 Btu/hat 5°F, full speed

    4 pairings · 47°F 20,800 Btu/h · 95°F cooling 21,200 Btu/h · Cold output 82% · COP 2.00

  3. RHMVY2417SEACN brand not stated 18,000 Btu/hat 5°F, full speed

    3 pairings · 47°F 21,400 Btu/h · 95°F cooling 21,400 Btu/h · Cold output 84% · COP 2.00

  4. SH2VY2417STACN brand not stated 18,000 Btu/hat 5°F, full speed

    3 pairings · 47°F 21,200 Btu/h · 95°F cooling 21,200 Btu/h · Cold output 85% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RH2VY3617STACN — 17,000 20,600 21,200 83% 2.00 Yes 5
RF2TY2421STANS — 17,000 20,800 21,200 82% 2.00 Yes 4
RHMVY2417SEACN — 18,000 21,400 21,400 84% 2.00 Yes 3
SH2VY2417STACN — 18,000 21,200 21,200 85% 2.00 Yes 3

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 19 indoor units All 399 certified pairings

Sold as, and units with identical certified values

Product history

  • RD18AY24AJVC changed its certified heat output at 47°F on 262 pairings in the certified data between August 2025 and September 2026. The new figure is lower on all 262.
  • RD18AY24AJVC first appeared in the certified data between February 2025 and March 2025.

History and definitions

Other K-SERIES models by nominal cooling size: FRP18AZ24AJVC (24,000 Btu), RD17AZ24AJ3N (24,000 Btu), RD18AY36AJVC (30,000 Btu), FRP18AZ36AJVC (36,000 Btu), FRP18AZ48AJVC (42,000 Btu), RD18AY48AJVC (42,000 Btu), RD17AZ48AJ3N (48,000 Btu), RD18AY60AJVC (48,000 Btu).

Other K-Series models by nominal cooling size: RD18AY36AJVC (30,000 Btu), RD18AY48AJVC (42,000 Btu), RD18AY60AJVC (48,000 Btu).

Other PRESTIGE SERIES models by nominal cooling size: RD17AZ24AJ3N (24,000 Btu), RP18AZ24AJVC (24,000 Btu), RP19AY24AJVC (24,000 Btu), RD18AY36AJVC (30,000 Btu), RD17AZ36AJ3N (36,000 Btu), RP18AZ36AJVC (36,000 Btu), RP19AY36AJVC (36,000 Btu), RD18AY48AJVC (42,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Oct 27, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “RD18AY24AJVC — certified heat output”. Certified figures dated , checked daily.