Heat Pump List

Tools

RP19AY24AJVC

RP19AY24AJVC is in the certified data.

Its certified full-speed heating output at 5°F is 17,400–19,500 Btu/h, 76–86% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Rheem · central heat pump

All 91 certified Rheem models

RP19AY24AJVC is in the certified data as of Oct 2, 2026. RP19AY24AJVC changed its certified SEER2 on AHRI certificate 215739589 from 19.0 to 20.0 in the certified data between August 2025 and September 2026.

32 certified pairings with 13 different figures. See all

Certified heating and cooling

Heating at 47°F

22,800

21,200 at 17°F

18,500 at 5°F

Btu/h, certified

1.80 COP at 5°F

Cooling at 95°F

22,800

Btu/h, certified

EER2 13.0 at 95°F

SEER2 21.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for RP19AY24AJVC, by outdoor temperature Heating: 18,500 Btu/h at 5°F, 21,200 Btu/h at 17°F, 22,800 Btu/h at 47°F. Cooling: 22,800 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 18,500 5°F 21,200 17°F 22,800 47°F 22,800 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 22,800 Btu/h of heat at 47°F, 21,200 Btu/h at 17°F, and 18,500 Btu/h at 5°F, 81% of its 47°F rating. It delivers 22,800 Btu/h of cooling at 95°F. At 5°F that is 500 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 13,300 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 216050993 · listed by Rheem · certified Sep 15, 2026 · 8 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 72 programs in 38 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (2), Connecticut (3), Delaware (2), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maine (2), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (7), New York (4), North Carolina (1), Oregon (2), Pennsylvania (4), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (3), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 72 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Delaware

Idaho

Illinois

Kansas

Kentucky

Maine

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 18,5005.42 kW −3% 1.80
17°Ffull speed 21,2006.21 kW +10% NR
47°Fnormal speed 22,8006.68 kW −5% NR
95°Fcooling, full load 22,8006.68 kW — NR

EER2 13.0 in that test. SEER2 21.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.01kW
Electrical input in the 95°F cooling test
1.75kW
Seasonal average heating COP
2.93

These exclude backup resistance heat.

Updated Oct 2, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
18,500 Btu/h
This unit at 5°F median across its pairings
18,500 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 42% of them, at number 327 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 24,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 219th of 565 (tied); HSPF2, 8th of 578 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • SH4BF5M2SX24K: The same 22,800 Btu/h rating at 47°F; 11,000 Btu/h at 5°F (this model: 18,500).
  • GSZH502410A: The same 22,800 Btu/h rating at 47°F; 11,300 Btu/h at 5°F (this model: 18,500).
  • RP15AZ24AJ2N: The same 22,800 Btu/h rating at 47°F; 12,300 Btu/h at 5°F (this model: 18,500).

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 18,500 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42440–770
MildTypical16–26710–1,160
MildTight, well insulated10–181,030–1,850
ColdDrafty, little insulation28–52360–660
ColdTypical18–30620–1,030
ColdTight, well insulated12–22840–1,540
Very coldDrafty, little insulation32–58320–580
Very coldTypical22–38490–840
Very coldTight, well insulated16–28660–1,160

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for RP19AY24AJVC

32 pairings · 32 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for RP19AY24AJVC
This pairingAll pairings
Heating
Heat output at 47°F normal speed 22,800 Btu/h 22,800–24,000 Btu/h
Heat output at 17°F full speed 21,200 Btu/h 20,200–21,200 Btu/h
Heat output at 5°F full speed 18,500 Btu/h 17,400–19,500 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 81%
COP at 5°F full speed 1.80 1.80–2.10
HSPF2 Region IV 10.0 8.5–10.0
Cooling
Cooling capacity at 95°F full-load test 22,800 Btu/h 22,800 Btu/h
EER2 at 95°F 13.0 12.0–13.0
SEER2 cooling season 21.0 20.0–21.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit RCFY2421HEAAM 2 indoor units
FurnaceR921V0403A17M4 31 furnaces
Cold-climate designation EPA's designation, as published Yes On some pairings
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold United States US and Canada
Model string as certified RP19AY24AJVC

Across 32 certified pairings with 2 indoor models: heat at 5°F 17,400 Btu/h with RCFY2421HEAAM to 19,500 Btu/h with RHMVY3621MEACA; HSPF2 8.5 with RCFY2421HEAAM to 10.0 with RCFY2421HEAAM; SEER2 20.0 with RCFY2421HEAAM to 21.0 with RCFY2421HEAAM. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

2 indoor units · 32 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 1 indoor unit

  1. RCFY2421HEAAM (the pairing on screen) brand not stated 18,500 Btu/hat 5°F, full speed

    31 pairings, 31 with a furnace · 47°F 22,800 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 81% · COP 1.80

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RCFY2421HEAAM (the pairing on screen) — 18,500 22,800 22,800 81% 1.80 Yes 31

Air handler · 1 indoor unit

  1. RHMVY3621MEACA brand not stated 19,500 Btu/hat 5°F, full speed

    1 pairing · 47°F 22,800 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 86% · COP 1.90

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RHMVY3621MEACA — 19,500 22,800 22,800 86% 1.90 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

2 of 3 shown.

Product history

  • RP19AY24AJVC changed its certified SEER2 on AHRI certificate 215739589 from 19.0 to 20.0 in the certified data between August 2025 and September 2026.
  • RP19AY24AJVC changed its certified HSPF2 on AHRI certificate 215739589 from 8.5 to 9.5 in the certified data between August 2025 and September 2026.
  • RP19AY24AJVC changed its certified EER2 on AHRI certificate 215739589 from 12.0 to 13.0 in the certified data between August 2025 and September 2026.
  • RP19AY24AJVC changed its certified heat output at 47°F on 26 pairings from 24,000 Btu/h to 22,800 Btu/h in the certified data between August 2025 and September 2026.
  • RP19AY24AJVC changed its certified heat output at 47°F on 27 pairings from 22,800 Btu/h to 24,000 Btu/h in the certified data between February 2025 and March 2025.
  • RP19AY24AJVC first appeared in the certified data between September 2024 and November 2024.

History and definitions

Other Prestige models by nominal cooling size: RP19AY36AJVC (36,000 Btu).

Other PRESTIGE SERIES models by nominal cooling size: RD18AY24AJVC (18,000 Btu), RD17AZ24AJ3N (24,000 Btu), RP18AZ24AJVC (24,000 Btu), RD18AY36AJVC (30,000 Btu), RD17AZ36AJ3N (36,000 Btu), RP18AZ36AJVC (36,000 Btu), RP19AY36AJVC (36,000 Btu), RD18AY48AJVC (42,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Sep 15, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “RP19AY24AJVC — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/rp19ay24ajvc