Heat Pump List

Tools

D5CURAH36AAK

D5CURAH36AAK is in the certified data.

Its certified full-speed heating output at 5°F is 27,000–29,200 Btu/h, 75–79% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Airquest, Arcoaire + 15 more · central heat pump

All 175 certified Airquest models · All 175 certified Arcoaire models · All 205 certified Bryant models · All 187 certified Carrier models · All 173 certified Comfortmaker models · All 177 certified Day & Night models · All 58 certified Grandaire models · All 176 certified Heil models · All 175 certified Keeprite models · All 179 certified Kenmore models · All 96 certified LPS Legacy models · All 359 certified Midea models · All 107 certified Payne models · All 108 certified Smart Comfort models · All 175 certified Tempstar models · All 62 certified Viessmann models · All 123 certified WeatherMaker models

D5CURAH36AAK is in the certified data as of Sep 19, 2026. D5CURAH36AAK changed its certified heat output at 17°F on 13 pairings from 24,800 Btu/h to 27,000 Btu/h in the certified data between August 2025 and September 2026.

30 certified pairings with 2 different figures. See all

Certified heating and cooling

Heating at 47°F

37,000

24,800 at 17°F

29,200 at 5°F

Btu/h, certified

1.99 COP at 5°F

Cooling at 95°F

36,000

Btu/h, certified

EER2 10.2 at 95°F

SEER2 16.7

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for D5CURAH36AAK, by outdoor temperature Heating: 29,200 Btu/h at 5°F, 24,800 Btu/h at 17°F, 37,000 Btu/h at 47°F. Cooling: 36,000 Btu/h at 95°F. The bars start at zero. Median of 3-ton central models: 26,400 Btu/h at 5°F, 26,200 Btu/h at 17°F, 35,200 Btu/h at 47°F, 35,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 29,200 5°F 24,800 17°F 37,000 47°F 36,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 37,000 Btu/h of heat at 47°F, 24,800 Btu/h at 17°F, and 29,200 Btu/h at 5°F, 79% of its 47°F rating. It delivers 36,000 Btu/h of cooling at 95°F. At 5°F that is 2,700 Btu/h above the example heating load of 26,500 Btu/h; at 95°F it is 23,000 Btu/h above the example cooling load of 13,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217730628 · listed by Carrier · certified Mar 11, 2026 · 17 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 58 programs in 36 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (1), Connecticut (3), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (3), New York (4), North Carolina (1), Oregon (2), Pennsylvania (1), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (1), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 58 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Idaho

Illinois

Kansas

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 29,2008.56 kW +11% 1.99
17°Ffull speed 24,8007.27 kW −5% NR
47°Fnormal speed 37,00010.84 kW +5% NR
95°Fcooling, full load 36,00010.55 kW — NR

EER2 10.2 in that test. SEER2 16.7 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
4.30kW
Electrical input in the 95°F cooling test
3.53kW
Seasonal average heating COP
2.73

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton central models

This pairing at 5°F
29,200 Btu/h
This unit at 5°F median across its pairings
29,200 Btu/h
Median of 3-ton central models at 5°F
26,400 Btu/h
Models in this group
451

This unit is above 62% of them, at number 170 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 36,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 184th of 451; HSPF2, 120th of 467 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • EZ-36-HPB: The same 37,000 Btu/h rating at 47°F; 39,000 Btu/h at 5°F (this model: 29,200).
  • BMSAH36HHC: The same 37,000 Btu/h rating at 47°F; 37,400 Btu/h at 5°F (this model: 29,200).
  • A-VXP36SA-1: The same 37,000 Btu/h rating at 47°F; 36,000 Btu/h at 5°F (this model: 29,200).

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 29,200 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42700–1,220
MildTypical16–261,120–1,830
MildTight, well insulated10–181,620–2,920
ColdDrafty, little insulation28–52560–1,040
ColdTypical18–30970–1,620
ColdTight, well insulated12–221,330–2,430
Very coldDrafty, little insulation32–58500–910
Very coldTypical22–38770–1,330
Very coldTight, well insulated16–281,040–1,830

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for D5CURAH36AAK

30 pairings · 30 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for D5CURAH36AAK
This pairingAll pairings
Heating
Heat output at 47°F normal speed 37,000 Btu/h 36,000–37,000 Btu/h
Heat output at 17°F full speed 24,800 Btu/h 24,800–27,000 Btu/h
Heat output at 5°F full speed 29,200 Btu/h 27,000–29,200 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 79%
COP at 5°F full speed 1.99 1.99–2.00
HSPF2 Region IV 9.3 8.7–9.3
Cooling
Cooling capacity at 95°F full-load test 36,000 Btu/h 36,000 Btu/h
EER2 at 95°F 10.2 10.0–10.2
SEER2 cooling season 16.7 16.2–16.7
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit D5MUWAQ36XA3 2 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified D5CURAH36AAK

Across 30 certified pairings with 2 indoor models: heat at 5°F 27,000 Btu/h with D5FUAAH36XAK to 29,200 Btu/h with D5MUWAQ36XA3; HSPF2 8.7 with D5FUAAH36XAK to 9.3 with D5MUWAQ36XA3; SEER2 16.2 with D5FUAAH36XAK to 16.7 with D5MUWAQ36XA3. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

2 indoor units · 30 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 2 indoor units

  1. D5MUWAQ36XA3 (the pairing on screen) brand not stated 29,200 Btu/hat 5°F, full speed

    17 pairings · 47°F 37,000 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 79% · COP 1.99

  2. D5FUAAH36XAK brand not stated 27,000 Btu/hat 5°F, full speed

    13 pairings · 47°F 36,000 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 75% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
D5MUWAQ36XA3 (the pairing on screen) — 29,200 37,000 36,000 79% 1.99 Yes 17
D5FUAAH36XAK — 27,000 36,000 36,000 75% 2.00 Yes 13

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Product history

  • D5CURAH36AAK changed its certified heat output at 17°F on 13 pairings from 24,800 Btu/h to 27,000 Btu/h in the certified data between August 2025 and September 2026.
  • D5CURAH36AAK changed its certified heat output at 17°F on 12 pairings from 25,600 Btu/h to 24,800 Btu/h in the certified data between November 2024 and February 2025.
  • D5CURAH36AAK was in the certified data by September 2024.

History and definitions

Other D5C Series models by nominal cooling size: D5CUHAH18AAK (18,000 Btu), D5CUHAH24AAK (24,000 Btu), D5CURAH24AAK (24,000 Btu), D5CUHAH30AAK (30,000 Btu), D5CUHAH36AAK (36,000 Btu), D5CUHAH48AAK (48,000 Btu), D5CUHAH60AAK (54,000 Btu).

Other D5F Series models by nominal cooling size: D5CPRAH06AAK (6,000 Btu), D5CPRAH09AAK (9,000 Btu), D5CPRAH12AAK (12,000 Btu), D5CPRAH18AA (18,000 Btu), D5CUHAH18AAK (18,000 Btu), D5CUHAH24AAK (24,000 Btu), D5CURAH24AAK (24,000 Btu), D5CUHAH30AAK (30,000 Btu); more models from this brand.

Other D5C Series models by nominal cooling size: D5CUHAH18AAK (18,000 Btu), D5CUHAH24AAK (24,000 Btu), D5CURAH24AAK (24,000 Btu), D5CUHAH30AAK (30,000 Btu), D5CUHAH36AAK (36,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Mar 11, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “D5CURAH36AAK — certified heat output”. Certified figures dated , checked daily.