D5CUHAH30AAK is in the certified data.

Its certified full-speed heating output at 5°F is 30,400–33,400 Btu/h, 86–107% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Airquest, Arcoaire + 15 more · central heat pump

All 175 certified Airquest models · All 175 certified Arcoaire models · All 205 certified Bryant models · All 187 certified Carrier models · All 173 certified Comfortmaker models · All 177 certified Day & Night models · All 58 certified Grandaire models · All 176 certified Heil models · All 175 certified Keeprite models · All 179 certified Kenmore models · All 96 certified LPS Legacy models · All 359 certified Midea models · All 107 certified Payne models · All 108 certified Smart Comfort models · All 175 certified Tempstar models · All 62 certified Viessmann models · All 123 certified WeatherMaker models

D5CUHAH30AAK is in the certified data as of Sep 19, 2026.

2,792 certified pairings with 162 different figures. See all

Certified heating and cooling

Heating at 47°F

36,400

21,000 at 17°F

32,400 at 5°F

Btu/h, certified

1.84 COP at 5°F

Cooling at 95°F

29,800

Btu/h, certified

EER2 9.8 at 95°F

SEER2 16.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for D5CUHAH30AAK, by outdoor temperature Heating: 32,400 Btu/h at 5°F, 21,000 Btu/h at 17°F, 36,400 Btu/h at 47°F. Cooling: 29,800 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton central models: 22,400 Btu/h at 5°F, 20,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 32,400 5°F 21,000 17°F 36,400 47°F 29,800 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 36,400 Btu/h of heat at 47°F, 21,000 Btu/h at 17°F, and 32,400 Btu/h at 5°F, 89% of its 47°F rating. It delivers 29,800 Btu/h of cooling at 95°F. At 5°F that is 9,900 Btu/h above the example heating load of 22,500 Btu/h; at 95°F it is 18,300 Btu/h above the example cooling load of 11,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218488644 · listed by Heil · certified Jun 16, 2026 · 48 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 54 programs in 34 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Connecticut (3), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (2), New Jersey (3), New York (4), North Carolina (1), Oregon (2), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (1), Utah (1), Vermont (3), Washington (2), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 54 programs by state and province

Alabama

Arizona

California

Connecticut

Idaho

Illinois

Kansas

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 32,4009.50 kW +45% 1.84
17°Ffull speed 21,0006.15 kW +2% NR
47°Fnormal speed 36,40010.67 kW +21% NR
95°Fcooling, full load 29,8008.73 kW — NR

EER2 9.8 in that test. SEER2 16.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
5.16kW
Electrical input in the 95°F cooling test
3.04kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton central models

This pairing at 5°F
32,400 Btu/h
This unit at 5°F median across its pairings
32,400 Btu/h
Median of 2.5-ton central models at 5°F
22,400 Btu/h
Models in this group
288

This unit is above 91% of them, at number 27 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 30,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 71st of 288 (tied); HSPF2, 154th of 290 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • MO1BE-H32B-2A: 36,000 Btu/h at 47°F (this model: 36,400); 26,400 Btu/h at 5°F (this model: 32,400).
  • KUSXA361A: 37,000 Btu/h at 47°F (this model: 36,400); HSPF2 9.3 (this model: 8.5).
  • 284ANV036*0**B*: 35,200 Btu/h at 47°F (this model: 36,400); 25,800 Btu/h at 5°F (this model: 32,400).

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 32,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42770–1,350
MildTypical16–261,250–2,030
MildTight, well insulated10–181,800–3,240
ColdDrafty, little insulation28–52620–1,160
ColdTypical18–301,080–1,800
ColdTight, well insulated12–221,470–2,700
Very coldDrafty, little insulation32–58560–1,010
Very coldTypical22–38850–1,470
Very coldTight, well insulated16–281,160–2,030

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for D5CUHAH30AAK

2,792 pairings · 2,792 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for D5CUHAH30AAK
This pairingAll pairings
Heating
Heat output at 47°F normal speed 36,400 Btu/h 30,000–37,400 Btu/h
Heat output at 17°F full speed 21,000 Btu/h 20,800–25,000 Btu/h
Heat output at 5°F full speed 32,400 Btu/h 30,400–33,400 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 89%
COP at 5°F full speed 1.84 1.75–2.00
HSPF2 Region IV 8.5 8.1–10.8
Cooling
Cooling capacity at 95°F full-load test 29,800 Btu/h 28,600–31,200 Btu/h
EER2 at 95°F 9.8 9.5–12.1
SEER2 cooling season 16.0 15.2–17.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit ESH5X42M12A* 26 indoor units
Furnace*80VSL0451412B* 70 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified D5CUHAH30AAK

Across 2,792 certified pairings with 26 indoor models: heat at 5°F 30,400 Btu/h with D5FULAH36XAX to 33,400 Btu/h with EA*5X30M17A*; HSPF2 8.1 with EA*5X30M17A* to 10.8 with D5FUHAH36XAK; SEER2 15.2 with EA*5X30M17A* to 17.5 with D5MUWAQ30XA3. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

26 indoor units · 2,792 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 9 indoor units

  1. ESH5X42M12A* (the pairing on screen) brand not stated 32,400 Btu/hat 5°F, full speed

    448 pairings, 56 with a furnace · 47°F 36,400 Btu/h · 95°F cooling 29,800 Btu/h · Cold output 89% · COP 1.82

  2. EA*5X37M21A* brand not stated 32,200 Btu/hat 5°F, full speed

    420 pairings, 54 with a furnace · 47°F 36,000 Btu/h · 95°F cooling 30,200 Btu/h · Cold output 89% · COP 1.96

  3. EA*5X43M21A* brand not stated 32,200 Btu/hat 5°F, full speed

    420 pairings, 54 with a furnace · 47°F 36,000 Btu/h · 95°F cooling 30,200 Btu/h · Cold output 89% · COP 1.98

  4. EA*5X42M21A* brand not stated 32,800 Btu/hat 5°F, full speed

    404 pairings, 52 with a furnace · 47°F 37,000 Btu/h · 95°F cooling 29,400 Btu/h · Cold output 89% · COP 1.80

  5. ESH5X36M12A* brand not stated 32,600 Btu/hat 5°F, full speed

    312 pairings, 39 with a furnace · 47°F 36,800 Btu/h · 95°F cooling 29,600 Btu/h · Cold output 89% · COP 1.82

  6. EA*5X37M17A* brand not stated 32,400 Btu/hat 5°F, full speed

    224 pairings, 28 with a furnace · 47°F 36,400 Btu/h · 95°F cooling 29,800 Btu/h · Cold output 89% · COP 1.94

  7. EA*5X36M17A* brand not stated 33,200 Btu/hat 5°F, full speed

    216 pairings, 27 with a furnace · 47°F 37,200 Btu/h · 95°F cooling 28,800 Btu/h · Cold output 89% · COP 1.78

  8. ESH5X30M12A* brand not stated 33,000 Btu/hat 5°F, full speed

    112 pairings, 14 with a furnace · 47°F 37,400 Btu/h · 95°F cooling 29,200 Btu/h · Cold output 88% · COP 1.80

  9. EA*5X30M17A* brand not stated 33,400 Btu/hat 5°F, full speed

    56 pairings, 7 with a furnace · 47°F 37,400 Btu/h · 95°F cooling 28,800 Btu/h · Cold output 89% · COP 1.76

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
ESH5X42M12A* (the pairing on screen) — 32,400 36,400 29,800 89% 1.82 Yes 448
EA*5X37M21A* — 32,200 36,000 30,200 89% 1.96 Yes 420
EA*5X43M21A* — 32,200 36,000 30,200 89% 1.98 Yes 420
EA*5X42M21A* — 32,800 37,000 29,400 89% 1.80 Yes 404
ESH5X36M12A* — 32,600 36,800 29,600 89% 1.82 Yes 312
EA*5X37M17A* — 32,400 36,400 29,800 89% 1.94 Yes 224
EA*5X36M17A* — 33,200 37,200 28,800 89% 1.78 Yes 216
ESH5X30M12A* — 33,000 37,400 29,200 88% 1.80 Yes 112
EA*5X30M17A* — 33,400 37,400 28,800 89% 1.76 Yes 56

Air handler · 1 indoor unit

  1. D5MUWAQ30XA3 brand not stated 32,000 Btu/hat 5°F, full speed

    17 pairings · 47°F 32,000 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 100% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
D5MUWAQ30XA3 — 32,000 32,000 30,000 100% 2.00 Yes 17

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 26 indoor units All 2,792 certified pairings

Sold as, and units with identical certified values

History and definitions

Other Crossover Heat Pump models by nominal cooling size: D5CUHAH18AAK (18,000 Btu), D5CUHAH24AAK (24,000 Btu), D5CURAH24AAK (24,000 Btu), D5CUHAH36AAK (36,000 Btu), D5CUHAH48AAK (48,000 Btu), D5CUHAH60AAK (54,000 Btu).

Other D5C Series models by nominal cooling size: D5CUHAH18AAK (18,000 Btu), D5CUHAH24AAK (24,000 Btu), D5CURAH24AAK (24,000 Btu), D5CUHAH36AAK (36,000 Btu), D5CURAH36AAK (36,000 Btu), D5CUHAH48AAK (48,000 Btu), D5CUHAH60AAK (54,000 Btu).

Other D5F Series models by nominal cooling size: D5CPRAH06AAK (6,000 Btu), D5CPRAH09AAK (9,000 Btu), D5CPRAH12AAK (12,000 Btu), D5CPRAH18AA (18,000 Btu), D5CUHAH18AAK (18,000 Btu), D5CUHAH24AAK (24,000 Btu), D5CURAH24AAK (24,000 Btu), D5CUHAH36AAK (36,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Jun 16, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “D5CUHAH30AAK — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/d5cuhah30aak