Heat Pump List

Tools

27SCA542A**30*

Carrier · central heat pump

All 187 certified Carrier models

27SCA542A**30* is in the certified data as of Sep 19, 2026. 27SCA542A**30* changed its certified COP at 5°F on AHRI certificate 216464100 from 2.10 to 2.26 in the certified data between August 2025 and September 2026.

5 certified pairings with 3 different figures. See all

Certified heating and cooling

Heating at 47°F

40,500

25,600 at 17°F

19,800 at 5°F

Btu/h, certified

2.24 COP at 5°F

Cooling at 95°F

43,000

Btu/h, certified

EER2 12.5 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for 27SCA542A**30*, by outdoor temperature Heating: 19,800 Btu/h at 5°F, 25,600 Btu/h at 17°F, 40,500 Btu/h at 47°F. Cooling: 43,000 Btu/h at 95°F. The bars start at zero. Median of 3.5-ton central models: 33,000 Btu/h at 5°F, 31,000 Btu/h at 17°F, 44,000 Btu/h at 47°F, 44,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 50,000 Btu/h 19,800 5°F 25,600 17°F 40,500 47°F 43,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 40,500 Btu/h of heat at 47°F, 25,600 Btu/h at 17°F, and 19,800 Btu/h at 5°F, 49% of its 47°F rating. It delivers 43,000 Btu/h of cooling at 95°F. At 5°F that is 13,200 Btu/h short of the example heating load of 33,000 Btu/h; at 95°F it is 26,000 Btu/h above the example cooling load of 17,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,400 sq ft where winters reach 5°F: heating runs from 33,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 17,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214277412 · listed by Carrier · certified Feb 10, 2026 · 1 pairing carries these values

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 19,8005.80 kW −40% 2.24
17°Fone compressor speed 25,6007.50 kW −17% NR
47°Fone compressor speed 40,50011.87 kW −8% NR
95°Fcooling, full load 43,00012.60 kW — NR

EER2 12.5 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.59kW
Electrical input in the 95°F cooling test
3.44kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 42,000 Btu heat pumps

3.5-ton central models

This pairing at 5°F
19,800 Btu/h
This unit at 5°F median across its pairings
19,800 Btu/h
Median of 3.5-ton central models at 5°F
33,000 Btu/h
Models in this group
222

This unit is above 10% of them, at number 200 of 222 by heat at 5°F. The middle half of the group runs 20,000 to 40,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 42,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 192nd of 222 (tied); HSPF2, 163rd of 224 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • RD18AY48AJVC: 41,000 Btu/h at 47°F (this model: 40,500); 37,600 Btu/h at 5°F (this model: 19,800).
  • GZV7SA4210A: 41,000 Btu/h at 47°F (this model: 40,500); 31,000 Btu/h at 5°F (this model: 19,800).
  • DZ6VSA421EA: 40,000 Btu/h at 47°F (this model: 40,500); 30,600 Btu/h at 5°F (this model: 19,800).

Closest models by heat at 5°F

Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 19,800 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42470–830
MildTypical16–26760–1,240
MildTight, well insulated10–181,100–1,980
ColdDrafty, little insulation28–52380–710
ColdTypical18–30660–1,100
ColdTight, well insulated12–22900–1,650
Very coldDrafty, little insulation32–58340–620
Very coldTypical22–38520–900
Very coldTight, well insulated16–28710–1,240

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for 27SCA542A**30*

5 pairings · 5 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for 27SCA542A**30*
This pairingAll pairings
Heating
Heat output at 47°F one speed 40,500 Btu/h 39,000–40,500 Btu/h
Heat output at 17°F full speed 25,600 Btu/h 24,600–25,600 Btu/h
Heat output at 5°F full speed 19,800 Btu/h 19,000–19,900 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 49%
COP at 5°F full speed 2.24 2.20–2.26
HSPF2 Region IV 7.8 7.8
Cooling
Cooling capacity at 95°F full-load test 43,000 Btu/h 41,500–43,000 Btu/h
EER2 at 95°F 12.5 11.7–13.0
SEER2 cooling season 15.2 15.2–15.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Single stage
Indoor unit FEVB0060**+NAVA56001CK 5 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified 27SCA542A**30*

Across 5 certified pairings with 5 indoor models: heat at 5°F 19,000 Btu/h with FG5ANBD60L* to 19,900 Btu/h with F55AA*D60L*; HSPF2 7.8 throughout; SEER2 15.2 with F55AA*D60L* to 15.5 with FG5ANBD60L*. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

5 indoor units · 5 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 5 indoor units

  1. F55AA*D60L* brand not stated 19,900 Btu/hat 5°F, full speed

    1 pairing · 47°F 40,500 Btu/h · 95°F cooling 42,500 Btu/h · Cold output 49% · COP 2.26

  2. FEVB0060**+NAVA56001CK (the pairing on screen) brand not stated 19,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 40,500 Btu/h · 95°F cooling 43,000 Btu/h · Cold output 49% · COP 2.24

  3. FG5ANBD60L* brand not stated 19,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 39,000 Btu/h · 95°F cooling 41,500 Btu/h · Cold output 49% · COP 2.20

  4. FJ5AN*D60L* brand not stated 19,900 Btu/hat 5°F, full speed

    1 pairing · 47°F 40,500 Btu/h · 95°F cooling 42,500 Btu/h · Cold output 49% · COP 2.26

  5. FT5ANBD60L* brand not stated 19,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 39,000 Btu/h · 95°F cooling 41,500 Btu/h · Cold output 49% · COP 2.20

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
F55AA*D60L* — 19,900 40,500 42,500 49% 2.26 NC 1
FEVB0060**+NAVA56001CK (the pairing on screen) — 19,800 40,500 43,000 49% 2.24 NC 1
FG5ANBD60L* — 19,000 39,000 41,500 49% 2.20 NC 1
FJ5AN*D60L* — 19,900 40,500 42,500 49% 2.26 NC 1
FT5ANBD60L* — 19,000 39,000 41,500 49% 2.20 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 5 of 5 indoor units

Sold as, and units with identical certified values

Product history

  • 27SCA542A**30* changed its certified COP at 5°F on AHRI certificate 216464100 from 2.10 to 2.26 in the certified data between August 2025 and September 2026.
  • 27SCA542A**30* changed its certified heat output at 5°F on AHRI certificate 216464100 from 19,700 Btu/h to 19,900 Btu/h in the certified data between August 2025 and September 2026.
  • 27SCA542A**30* changed its certified heat output at 17°F on AHRI certificate 214277412 from 25,400 Btu/h to 25,600 Btu/h in the certified data between August 2025 and September 2026.
  • 27SCA542A**30* was in the certified data by September 2024.

History and definitions

Other COMFORT 15 SEER2 HP models by nominal cooling size: 25SCA518A**30* (18,000 Btu), 27SCA531A**30* (30,000 Btu), 25SCA536A**30* (36,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Feb 10, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “27SCA542A**30* — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/gh5san542_st_staa_st