Heat Pump List

Tools

Are Fraser-Johnston and Kenmore heat pumps the same?

19 model numbers are listed under both Fraser-Johnston and Kenmore. For 3 of them the certified record is the same record under each brand.

  • 19 shared model numbers
  • 3 identical records
  • 16 records that differ
  • Updated Oct 18, 2026

How much of each range overlaps

Each brand's range, and how much of it is shared with the other
Brand Units in the certified data Certified combinations Share of its range that is shared
Fraser-Johnston 47 8,610 40.4%
Kenmore 179 10,656 10.6%

“Share of its range” is shared model numbers divided by that brand's own units. The two shares differ because the two ranges are different sizes. One row per unit (a certified model number), not per brand entry.

The model numbers they share

19 of 19 shown

Model numbers listed under both brands. The 5°F figure is the median across that unit's own certified pairings.

Model numbers listed under both Fraser-Johnston and Kenmore
Model number Size class TypeHeat at 5°FBtu/hkW COP at 5°F Pairings Fraser-Johnston Kenmore Same record Cold climate
XH960E2C11 48,000 Btu (4-ton) central 45,000 2.00 858 165 49 Differs Yes
HH860E2S12 42,000 Btu (3.5-ton) central 34,400 2.24 2,207 373 237 Differs Yes
HH860E2S11 42,000 Btu (3.5-ton) central 33,800 2.00 3,582 584 207 Differs Yes
XH936E2C11 36,000 Btu (3-ton) central 32,600 2.00 836 159 49 Differs Yes
XH560E2S11 54,000 Btu (4.5-ton) central 31,600 2.30 215 42 22 Identical NC
XH660E2S11 54,000 Btu (4.5-ton) central 31,600 2.26 1,300 222 103 Differs NC
HH836E2S12 30,000 Btu (2.5-ton) central 27,400 2.30 3,583 605 357 Differs Yes
XH648E2S11 48,000 Btu (4-ton) central 27,200 2.26 3,010 516 223 Differs NC
XH548E2S11 48,000 Btu (4-ton) central 26,000 2.36 1,789 355 149 Identical NC
HH836E2S11 36,000 Btu (3-ton) central 25,400 2.00 5,267 867 385 Differs Yes
XH636E2S11 36,000 Btu (3-ton) central 18,800 2.36 2,632 455 224 Differs NC
HH824E2S11 24,000 Btu (2-ton) central 18,500 2.00 1,944 318 103 Differs Yes
HH824E2S12 24,000 Btu (2-ton) central 18,100 2.32 1,435 242 147 Differs Yes
XH536E2S11 36,000 Btu (3-ton) central 17,700 2.32 1,364 273 122 Differs NC
XH630E2S11 30,000 Btu (2.5-ton) central 15,600 2.30 1,064 228 104 Differs NC
XH524E2S11 24,000 Btu (2-ton) central 12,400 2.24 290 55 40 Identical NC
XH624E2S11 24,000 Btu (2-ton) central 12,300 2.24 875 148 65 Differs NC
XH518E2S11 18,000 Btu (1.5-ton) central 8,900 2.30 1,012 198 95 Differs NC
XH618E2S11 18,000 Btu (1.5-ton) central 8,900 2.28 1,266 272 146 Differs NC

NC not cold-climate certified — not in the certified data

19 of 19 shared model numbers All brand pairs