PHG6B361002X4
Champion, Coleman + 4 more · central heat pump
All 48 certified Champion models · All 66 certified Coleman models · All 47 certified Fraser-Johnston models · All 34 certified Johnson Controls models · All 64 certified Luxaire models · All 105 certified York models
PHG6B361002X4 is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
32,6009.55NR
No 47°F rating for this pairing.
22,0006.45NR at 17°F
30,6008.97NR at 5°F
Btu/hkW, certified
2.14NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 32,600 Btu/h9.55 kW of heat at 47°F, 22,000 Btu/h6.45 kW at 17°F, and 30,600 Btu/h8.97 kW at 5°F, 94% of its 47°F rating. It delivers 36,600 Btu/h10.73 kW of cooling at 95°F. At 5°F that is 4,100 Btu/h1.20 kW above the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 23,600 Btu/h6.92 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 208106596 · listed by CHAMPION HEATING AND COOLING · certified Jul 7, 2026 · 6 pairings on 6 certificates share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 30,6008.97 kW | +16% | 2.14 | |
| 17°Ffull speed | 22,0006.45 kW | −16% | NR | |
| 47°Fhigh stage | 32,6009.55 kW | −7% | NR | |
| 95°Fcooling, full load | 36,60010.73 kW | — | NR |
EER2 12.0 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.19kW
- Electrical input in the 95°F cooling test
- 3.05kW
- Seasonal average heating COP
- 2.11
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 30,600 Btu/h8.97 kWNR
- This unit at 5°F median across its pairings
- 30,600 Btu/h8.97 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 68% of them, at number 144 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Among 36,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 70th of 451 (tied); HSPF2, 445th of 467 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- GZV9SA361CA: The same 32,600 Btu/h rating at 47°F; HSPF2 9.2 (this model: 7.2).
- 5TWR7036A1: The same 32,600 Btu/h rating at 47°F; 24,200 Btu/h at 5°F (this model: 30,600).
- EL19KPV-036-230A: 32,400 Btu/h at 47°F (this model: 32,600); 15,100 Btu/h at 5°F (this model: 30,600).
Closest models by heat at 5°F
- AC036BXUDCHSamsung · 31,600 Btu/h
- AZPN/36WACKepler · 31,600 Btu/h
- RP17AY36AJVCRheem and Ruud · 31,000 Btu/h
- 37MUHAQ36AA3Bryant, Carrier + 3 more · 30,400 Btu/h
- D5CUHAH36AAKAirquest, Arcoaire + 15 more · 30,400 Btu/h
- AZPN/C36WDUIDKepler · 30,000 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 30,600 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 730–1,280 |
| Mild | Typical | 16–26 | 1,180–1,910 |
| Mild | Tight, well insulated | 10–18 | 1,700–3,060 |
| Cold | Drafty, little insulation | 28–52 | 590–1,090 |
| Cold | Typical | 18–30 | 1,020–1,700 |
| Cold | Tight, well insulated | 12–22 | 1,390–2,550 |
| Very cold | Drafty, little insulation | 32–58 | 530–960 |
| Very cold | Typical | 22–38 | 810–1,390 |
| Very cold | Tight, well insulated | 16–28 | 1,090–1,910 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for PHG6B361002X4
6 pairings · 6 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 32,600 Btu/h9.55 kWNR | 32,600 Btu/h9.55 kW |
| Heat output at 17°F full speed | 22,000 Btu/h6.45 kWNR | 22,000 Btu/h6.45 kW |
| Heat output at 5°F full speed | 30,600 Btu/h8.97 kWNR | 30,600 Btu/h8.97 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 94%NR | |
| COP at 5°F full speed | 2.14NR | 2.14 |
| HSPF2 Region IV | 7.2NR | 7.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 36,600 Btu/h10.73 kWNR | 36,600 Btu/h10.73 kW |
| EER2 at 95°F | 12.0NR | 12.0 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | PHG6B361002X4 | |
Pairings, by indoor-unit class
6 certified pairings
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 30,600 Btu/h8.97 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 30,6008.97 | 32,6009.55 | 36,60010.73 | 94% | 2.14 | NC | 6 |
Sold as, and units with identical certified values
Brands listing this model number
- Champion1 pairing
- Coleman1 pairing
- Fraser-Johnston1 pairing
- Johnson Controls1 pairing
- Luxaire1 pairing
- York1 pairing
Other brands that list these model numbers
- Are Champion and Luxaire heat pumps the same?48 shared model numbers
- Are Champion and Fraser-Johnston heat pumps the same?47 shared model numbers
- Are Champion and Coleman heat pumps the same?44 shared model numbers
- Are Champion and Johnson Controls heat pumps the same?34 shared model numbers
- Are Champion and York heat pumps the same?17 shared model numbers
- Are Coleman and Luxaire heat pumps the same?60 shared model numbers
- Are Coleman and Fraser-Johnston heat pumps the same?43 shared model numbers
Model number as listed
- PHG6B361002X4 6 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- PHG6B361002X4 first appeared in the certified data between September 2024 and November 2024.
History and definitions
Other LX SERIES models by nominal cooling size: THF2B18S21 (18,000 Btu), HH824E2S11 (24,000 Btu), HH824E2S12 (24,000 Btu), PHE6A2424 (24,000 Btu), PHG6A240752X4 (24,000 Btu), THF2B24T21 (24,000 Btu), HH836E2S12 (30,000 Btu), THF2B30T21 (30,000 Btu); more models from this brand.
Other LX SERIES models by nominal cooling size: THF2B18S21 (18,000 Btu), HH824E2S11 (24,000 Btu), PHE6A2424 (24,000 Btu), PHG6A240752X4 (24,000 Btu), THF2B24T21 (24,000 Btu), THF2B30T21 (30,000 Btu), HH836E2S11 (36,000 Btu), PHE6B3624 (36,000 Btu); more models from this brand.
Other LX SERIES models by nominal cooling size: YH2F18SB21 (18,000 Btu), YH518E2S11 (18,000 Btu), YH618E2S11 (18,000 Btu), HH824E2S11 (24,000 Btu), HH824E2S12 (24,000 Btu), PHE6A2424 (24,000 Btu), YH2F24TB21 (24,000 Btu), YH524E2S11 (24,000 Btu); more models from this brand.
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 7, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read