THF2B48T21 is in the certified data.

Its certified full-speed heating output at 5°F is 23,400–29,800 Btu/h, 53–66% of its 47°F rating, depending on the pairing.

Champion, Coleman + 3 more · central heat pump

All 48 certified Champion models · All 66 certified Coleman models · All 47 certified Fraser-Johnston models · All 34 certified Johnson Controls models · All 64 certified Luxaire models

THF2B48T21 is in the certified data as of Sep 19, 2026.

1,798 certified pairings with 101 different figures. See all

Certified heating and cooling

Heating at 47°F

44,000

30,600 at 17°F

24,400 at 5°F

Btu/h, certified

2.40 COP at 5°F

Cooling at 95°F

45,500

Btu/h, certified

EER2 11.7 at 95°F

SEER2 16.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for THF2B48T21, by outdoor temperature Heating: 24,400 Btu/h at 5°F, 30,600 Btu/h at 17°F, 44,000 Btu/h at 47°F. Cooling: 45,500 Btu/h at 95°F. The bars start at zero. Median of 4-ton central models: 36,400 Btu/h at 5°F, 35,000 Btu/h at 17°F, 48,000 Btu/h at 47°F, 48,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 50,000 Btu/h 24,400 5°F 30,600 17°F 44,000 47°F 45,500 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 44,000 Btu/h of heat at 47°F, 30,600 Btu/h at 17°F, and 24,400 Btu/h at 5°F, 55% of its 47°F rating. It delivers 45,500 Btu/h of cooling at 95°F. At 5°F that is 12,100 Btu/h short of the example heating load of 36,500 Btu/h; at 95°F it is 27,500 Btu/h above the example cooling load of 18,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 212413819 · listed by Coleman · certified Jul 7, 2026 · 25 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 26 programs in 16 states, provinces, or territories:Colorado (1), Idaho (1), Kansas (1), Maryland (3), Michigan (2), Minnesota (2), Mississippi (1), Nevada (1), New Jersey (4), North Carolina (1), Oregon (2), Pennsylvania (3), South Carolina (1), Texas (3), Utah (1), Newfoundland and Labrador (1).

All 26 programs by state and province

Colorado

Idaho

Kansas

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Jersey

North Carolina

Oregon

Pennsylvania

South Carolina

Texas

Utah

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 24,4007.15 kW −33% 2.40
17°Fone compressor speed 30,6008.97 kW −13% NR
47°Fone compressor speed 44,00012.90 kW −8% NR
95°Fcooling, full load 45,50013.33 kW — NR

EER2 11.7 in that test. SEER2 16.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.98kW
Electrical input in the 95°F cooling test
3.89kW
Seasonal average heating COP
2.37

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 48,000 Btu heat pumps

4-ton central models

This pairing at 5°F
24,400 Btu/h
This unit at 5°F median across its pairings
24,400 Btu/h
Median of 4-ton central models at 5°F
36,400 Btu/h
Models in this group
408

This unit is above 16% of them, at number 344 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 48,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 322nd of 408 (tied); HSPF2, 368th of 420 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • 4TWV7X48A1: The same 44,000 Btu/h rating at 47°F; 28,400 Btu/h at 5°F (this model: 24,400).
  • 50NR-B48---30: 44,500 Btu/h at 47°F (this model: 44,000); 18,200 Btu/h at 5°F (this model: 24,400).
  • 4A6L9048A1: 43,500 Btu/h at 47°F (this model: 44,000); HSPF2 9.0 (this model: 7.8).

Closest models by heat at 5°F

Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 24,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42580–1,020
MildTypical16–26940–1,530
MildTight, well insulated10–181,360–2,440
ColdDrafty, little insulation28–52470–870
ColdTypical18–30810–1,360
ColdTight, well insulated12–221,110–2,030
Very coldDrafty, little insulation32–58420–760
Very coldTypical22–38640–1,110
Very coldTight, well insulated16–28870–1,530

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for THF2B48T21

1,798 pairings · 1,798 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for THF2B48T21
This pairingAll pairings
Heating
Heat output at 47°F high stage 44,000 Btu/h 43,500–47,500 Btu/h
Heat output at 17°F full speed 30,600 Btu/h 29,200–34,200 Btu/h
Heat output at 5°F full speed 24,400 Btu/h 23,400–29,800 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 55%
COP at 5°F full speed 2.40 2.22–2.84
HSPF2 Region IV 8.1 7.8–8.1
Cooling
Cooling capacity at 95°F full-load test 45,500 Btu/h 44,500–47,500 Btu/h
EER2 at 95°F 11.7 11.0–12.0
SEER2 cooling season 16.0 15.2–16.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Two-stage
Indoor unit XAHC60HBCN1 38 indoor units
FurnaceZ8ES100C20SMPS1 95 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On some pairings
Where it is sold US and Canada US and Canada
Model string as certified THF2B48T21

Across 1,798 certified pairings with 38 indoor models: heat at 5°F 23,400 Btu/h with XAFC60HBCN1 to 29,800 Btu/h with JHETC60HBCS2N1; HSPF2 7.8 with JHETC60HBCS2N1 to 8.1 with JHETD48GBCS2N1; SEER2 15.2 with JHETC60HBCS2N1 to 16.0 with JHETD60HBCS2N1. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

38 indoor units · 1,798 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. XAHC60HBCN1 (the pairing on screen) brand not stated 25,000 Btu/hat 5°F, full speed

    294 pairings, 70 with a furnace · 47°F 44,000 Btu/h · 95°F cooling 45,500 Btu/h · Cold output 56% · COP 2.46

  2. XAHC60GBCN1 brand not stated 24,200 Btu/hat 5°F, full speed

    267 pairings, 63 with a furnace · 47°F 45,000 Btu/h · 95°F cooling 46,000 Btu/h · Cold output 54% · COP 2.26

  3. XAHD60HBCN1 brand not stated 25,000 Btu/hat 5°F, full speed

    266 pairings, 66 with a furnace · 47°F 44,000 Btu/h · 95°F cooling 45,500 Btu/h · Cold output 57% · COP 2.46

  4. XAFC60HBCN1 brand not stated 23,800 Btu/hat 5°F, full speed

    264 pairings, 64 with a furnace · 47°F 43,500 Btu/h · 95°F cooling 45,000 Btu/h · Cold output 55% · COP 2.28

  5. XAFD60HBCN1 brand not stated 23,800 Btu/hat 5°F, full speed

    247 pairings, 59 with a furnace · 47°F 43,500 Btu/h · 95°F cooling 45,000 Btu/h · Cold output 55% · COP 2.28

  6. XAHD60GBCN1 brand not stated 24,000 Btu/hat 5°F, full speed

    223 pairings, 51 with a furnace · 47°F 45,000 Btu/h · 95°F cooling 46,000 Btu/h · Cold output 53% · COP 2.24

  7. XAHD60GXXN1+TXV brand not stated 24,000 Btu/hat 5°F, full speed

    30 pairings, 9 with a furnace · 47°F 45,000 Btu/h · 95°F cooling 46,000 Btu/h · Cold output 53% · COP 2.24

  8. XAHD60HXXN1+TXV brand not stated 25,000 Btu/hat 5°F, full speed

    20 pairings, 7 with a furnace · 47°F 44,000 Btu/h · 95°F cooling 45,000 Btu/h · Cold output 57% · COP 2.46

  9. XAHC60HXXN1+TXV brand not stated 25,000 Btu/hat 5°F, full speed

    18 pairings, 6 with a furnace · 47°F 44,000 Btu/h · 95°F cooling 45,500 Btu/h · Cold output 57% · COP 2.48

  10. XAFC60HXXN1+TXV brand not stated 23,800 Btu/hat 5°F, full speed

    12 pairings, 3 with a furnace · 47°F 43,500 Btu/h · 95°F cooling 45,500 Btu/h · Cold output 55% · COP 2.28

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
XAHC60HBCN1 (the pairing on screen) — 25,000 44,000 45,500 56% 2.46 NC 294
XAHC60GBCN1 — 24,200 45,000 46,000 54% 2.26 NC 267
XAHD60HBCN1 — 25,000 44,000 45,500 57% 2.46 NC 266
XAFC60HBCN1 — 23,800 43,500 45,000 55% 2.28 NC 264
XAFD60HBCN1 — 23,800 43,500 45,000 55% 2.28 NC 247
XAHD60GBCN1 — 24,000 45,000 46,000 53% 2.24 NC 223
XAHD60GXXN1+TXV — 24,000 45,000 46,000 53% 2.24 NC 30
XAHD60HXXN1+TXV — 25,000 44,000 45,000 57% 2.46 NC 20
XAHC60HXXN1+TXV — 25,000 44,000 45,500 57% 2.48 NC 18
XAFC60HXXN1+TXV — 23,800 43,500 45,500 55% 2.28 NC 12

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 38 indoor units All 1,798 certified pairings

Sold as, and units with identical certified values

History and definitions

Other LX SERIES models by nominal cooling size: THF2B18S21 (18,000 Btu), HH824E2S11 (24,000 Btu), HH824E2S12 (24,000 Btu), PHE6A2424 (24,000 Btu), PHG6A240752X4 (24,000 Btu), THF2B24T21 (24,000 Btu), HH836E2S12 (30,000 Btu), THF2B30T21 (30,000 Btu); more models from this brand.

Other LX SERIES models by nominal cooling size: THF2B18S21 (18,000 Btu), HH824E2S11 (24,000 Btu), PHE6A2424 (24,000 Btu), PHG6A240752X4 (24,000 Btu), THF2B24T21 (24,000 Btu), THF2B30T21 (30,000 Btu), HH836E2S11 (36,000 Btu), PHE6B3624 (36,000 Btu); more models from this brand.

History

First certified record
Most recent certified record
Measurements reported
Jul 7, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read