Heat Pump List

Tools

New England Heat Pump Accelerator · page 11

New England Heat Pump Accelerator · Connecticut, Massachusetts, New Hampshire, and Rhode Island, United States · Open

The New England Heat Pump Accelerator takes $650 off the distributor's price of each outdoor unit that meets its criteria, for up to two per home. The contractor passes along the discount.

2,097 of the 3,004 certified heat pumps in our data sold in the United States meet the published thresholds for $650 of New England Heat Pump Accelerator as of Sep 28, 2026.

The program's own qualified product list decides which models it accepts. This page compares the certified figures with the thresholds the program publishes.

Programs change their thresholds. Check the program page before you buy.

The list

  1. 2001 PUZ-HA24NHAMitsubishi Electric
    25,400 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 25,400 Btu/h · Cold output 89–100% · HSPF2 9.3 · 3 pairings

  2. 2002 CU-HM30BAHUPanasonic
    29,000 Btu/hheating at 47°F 29,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 29,000 Btu/h · Cold output 96–107% · HSPF2 8.8 · 13 pairings

  3. 2003 ACIQ-48-EHPD1HVAC, ACiQ
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 38,000 Btu/h · Cold output 79–85% · HSPF2 8.8 · 4 pairings

  4. 2004 BNG2A48SCNBlueridge
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 38,000 Btu/h · Cold output 79–85% · HSPF2 8.8 · 2 pairings

  5. 2005 DRU1H30S2ADuraSTAR
    29,000 Btu/hheating at 47°F 29,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 29,000 Btu/h · Cold output 90–107% · HSPF2 8.7 · 49 pairings

  6. 2006 MO1HE-H30B-2AMidea
    29,000 Btu/hheating at 47°F 29,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 29,000 Btu/h · Cold output 90–107% · HSPF2 8.7 · 114 pairings

  7. 2007 CU-M36BAHUPanasonic
    36,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 26,000 Btu/h · Cold output 72–75% · HSPF2 8.6 · 4 pairings

  8. 2008 CCB1-H36A-OCapella
    36,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 34,000 Btu/h · Cold output 89–105% · HSPF2 9.4 · 6 pairings

  9. 2009 AUWR-48U3SPHisense
    42,000 Btu/hheating at 47°F 42,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 34,600 Btu/h · Cold output 82% · HSPF2 8.6 · 1 pairing

  10. 2010 TZID36H520ZCSThermal Zone
    36,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 26,000 Btu/h · Cold output 72–75% · HSPF2 8.5 · 12 pairings

  11. 2011 DLCURAH36ABKAirquest, Arcoaire + 12 more
    39,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 32,000 Btu/h · Cold output 82–86% · HSPF2 9.5 · 48 pairings

  12. 2012 MOE31U-36HFN1-MAlsetria, CanAir + 4 more
    39,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 32,000 Btu/h · Cold output 82–100% · HSPF2 9.5 · 19 pairings

  13. 2013 AUWR-36U3SAHisense
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 24,200 Btu/h · Cold output 81% · HSPF2 9.4 · 1 pairing

  14. 2014 DRU1H36S2ADuraSTAR
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 33,000 Btu/h · Cold output 86–105% · HSPF2 9.3 · 47 pairings

  15. 2015 MO1SE-H36B-2AMidea
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 33,000 Btu/h · Cold output 86–105% · HSPF2 9.3 · 120 pairings

  16. 2016 BZ33-INV36OUT2-JBreeze33
    39,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 32,000 Btu/h · Cold output 82–88% · HSPF2 9.2 · 3 pairings

  17. 2017 1824SPV0-HP-X-DMulti MFG
    16,800 Btu/hheating at 47°F 16,800 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Central · 5°F 12,800 Btu/h · Cold output 76% · HSPF2 9.1 · 1 pairing

  18. 2018 PUZ-HA42NKA1Mitsubishi Electric, Trane / Mitsubishi Electric
    54,000 Btu/hheating at 47°F 42,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Mini-split · 5°F 48,000 Btu/h · Cold output 89% · HSPF2 9.0 · 7 pairings

  19. 2019 TRUZH0421KA10NATrane / Mitsubishi Electric
    54,000 Btu/hheating at 47°F 42,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Mini-split · 5°F 48,000 Btu/h · Cold output 89% · HSPF2 9.0 · 3 pairings

  20. 2020 BZ33-INV30OUT2-JBreeze33
    31,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 25,000 Btu/h · Cold output 73–82% · HSPF2 9.0 · 3 pairings

  21. 2021 37MUHAQ48AA3Bryant, Carrier + 3 more
    50,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 46,000 Btu/h · Cold output 88–100% · HSPF2 8.8 · 31 pairings

  22. 2022 D5CUHAH48AAKAirquest, Arcoaire + 11 more
    50,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 46,000 Btu/h · Cold output 88–100% · HSPF2 8.8 · 55 pairings

  23. 48,000 Btu/hheating at 47°F 51,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 40,000 Btu/h · Cold output 70–83% · HSPF2 8.6 · 3 pairings

  24. 2024 BOHA-60RTB-M18SBosch
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Central · 5°F 39,000 Btu/h · Cold output 69–81% · HSPF2 8.6 · 19 pairings

  25. 2025 AZPN/36WACKepler
    38,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 31,600 Btu/h · Cold output 83% · HSPF2 8.6 · 1 pairing

  26. 2026 25SPV0-HP-X-DMulti MFG
    25,000 Btu/hheating at 47°F 25,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 18,900 Btu/h · Cold output 76% · HSPF2 8.6 · 1 pairing

  27. 2027 UHP18048-OMRCOOL
    48,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 42,000 Btu/h · Cold output 87–100% · HSPF2 8.5 · 5 pairings

  28. 47,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 41,000 Btu/h · Cold output 87–92% · HSPF2 8.5 · 8 pairings

  29. 2029 37MURAQ48AA3Bryant, Carrier + 3 more
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 38,000 Btu/h · Cold output 77–85% · HSPF2 8.5 · 17 pairings

  30. 2030 MO1BE-H60B-2AMidea
    47,000 Btu/hheating at 47°F 51,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 38,000 Btu/h · Cold output 70–83% · HSPF2 8.5 · 21 pairings

  31. 2031 37MUHAQ36AA3Bryant, Carrier + 3 more
    38,000 Btu/hheating at 47°F 35,600 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 30,400 Btu/h · Cold output 78–105% · HSPF2 8.5 · 1,186 pairings

  32. 2032 D5CUHAH36AAKAirquest, Arcoaire + 15 more
    38,000 Btu/hheating at 47°F 35,600 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 30,400 Btu/h · Cold output 78–105% · HSPF2 8.5 · 2,634 pairings

  33. 2033 27VPA936A*030*Carrier
    36,200 Btu/hheating at 47°F 34,400 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central Cold climate on some pairings · 5°F 25,600 Btu/h · Cold output 67–82% · HSPF2 8.5 · 497 pairings

  34. 2034 D5CURAH24AAKAirquest, Arcoaire + 15 more
    24,000 Btu/hheating at 47°F 23,600 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 19,300 Btu/h · Cold output 76–83% · HSPF2 8.5 · 1,095 pairings

  35. 2035 D5CUHAH18AAKAirquest, Arcoaire + 15 more
    19,800 Btu/hheating at 47°F 17,700 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Central · 5°F 16,800 Btu/h · Cold output 83–103% · HSPF2 8.5 · 591 pairings

  36. 2036 SPHP-Z-V037BBAC Pro
    37,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 36,000 Btu/h · Cold output 97% · HSPF2 9.8 · 1 pairing

  37. 22,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 16,000 Btu/h · Cold output 73% · HSPF2 9.2 · 1 pairing

  38. 2038 PUZ-HA42NKAMitsubishi Electric
    54,000 Btu/hheating at 47°F 42,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Mini-split · 5°F 48,000 Btu/h · Cold output 89% · HSPF2 8.9 · 1 pairing

  39. 47,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 40,000 Btu/h · Cold output 79–93% · HSPF2 8.9 · 8 pairings

  40. 2040 SPHP-Y-V036BBAC Pro
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 27,000 Btu/h · Cold output 72–77% · HSPF2 8.7 · 3 pairings

  41. 2041 MO1BE-H36B-2AMidea
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 26,000 Btu/h · Cold output 72–79% · HSPF2 8.4 · 29 pairings

  42. 36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 26,000 Btu/h · Cold output 72–75% · HSPF2 8.2 · 3 pairings

  43. 2043 TZPLV482PAThermal Zone
    50,000 Btu/hheating at 47°F 47,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 46,000 Btu/h · Cold output 85–92% · HSPF2 9.3 · 2 pairings

  44. 2044 AVE09N3H1Ephoca, Innova
    8,200 Btu/hheating at 47°F 7,500 Btu/hcooling at 95°F

    6,000 Btu · Central · 5°F 6,400 Btu/h · Cold output 78% · HSPF2 9.9 · 2 pairings

  45. 2045 DIRM4-48MAGICPRO20-OUDirect Air
    48,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 42,000 Btu/h · Cold output 87–92% · HSPF2 8.7 · 4 pairings

  46. 2046 MSHMB36R2ANMoovAir
    38,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 34,000 Btu/h · Cold output 89–92% · HSPF2 9.6 · 2 pairings

  47. 2047 DLCURAH60ABKAirquest, Arcoaire + 12 more
    59,000 Btu/hheating at 47°F 55,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Central · 5°F 48,500 Btu/h · Cold output 82% · HSPF2 9.4 · 22 pairings

  48. 37,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 33,000 Btu/h · Cold output 87–105% · HSPF2 9.2 · 21 pairings

  49. 2049 ACK09N3H1Ephoca, Innova
    8,200 Btu/hheating at 47°F 6,100 Btu/hcooling at 95°F

    6,000 Btu · Central · 5°F 5,900 Btu/h · Cold output 72% · HSPF2 9.2 · 2 pairings

  50. 2050 MDV-V30WMN10T-HMidea
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 26,000 Btu/h · Cold output 87% · HSPF2 8.5 · 1 pairing

  51. 2051 MDV-V24WMN10T-HMidea
    24,000 Btu/hheating at 47°F 23,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 19,400 Btu/h · Cold output 81% · HSPF2 8.5 · 1 pairing

  52. 2052 AC048FCUPCGSamsung
    48,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 39,500 Btu/h · Cold output 75–84% · HSPF2 8.2 · 7 pairings

  53. 2053 DIRM-60MAGICPRO20-OUDirect Air
    55,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 46,500 Btu/h · Cold output 82–85% · HSPF2 9.3 · 2 pairings

  54. 2054 MHSD136DACFCConforto, EMI
    39,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 32,000 Btu/h · Cold output 82–86% · HSPF2 10.0 · 6 pairings

  55. 2055 MHD-24Dettson, Innovair
    24,600 Btu/hheating at 47°F 23,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 23,000 Btu/h · Cold output 93% · HSPF2 9.8 · 2 pairings

  56. 2056 MHD-18Dettson, Innovair
    19,500 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Central · 5°F 14,600 Btu/h · Cold output 75% · HSPF2 9.5 · 2 pairings

  57. 2057 SUZ-KA36NAHZMitsubishi Electric
    40,000 Btu/hheating at 47°F 33,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 38,000 Btu/h · Cold output 95% · HSPF2 9.3 · 1 pairing

  58. 2058 MOE30U-45HFN1-MAlsetria, Eco Air, MDV
    55,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 46,500 Btu/h · Cold output 85% · HSPF2 9.2 · 3 pairings

  59. 2059 5HCL6036A1000ATrane/American Standard
    40,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 37,000 Btu/h · Cold output 93% · HSPF2 9.1 · 1 pairing

  60. 2060 WSCHV0048BA1-CContinental
    47,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 40,000 Btu/h · Cold output 85% · HSPF2 9.0 · 1 pairing

  61. 2061 YDV36E2D11York
    34,000 Btu/hheating at 47°F 32,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 23,800 Btu/h · Cold output 70–73% · HSPF2 9.0 · 7 pairings

  62. 2062 9SPV0-HP-X-DMulti MFG
    9,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Central · 5°F 8,000 Btu/h · Cold output 89% · HSPF2 8.9 · 1 pairing

  63. 2063 A-KXP48TA-1Kerr
    48,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 42,000 Btu/h · Cold output 88% · HSPF2 8.8 · 1 pairing

  64. 2064 CCB1-H48A-OCapella
    48,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 42,000 Btu/h · Cold output 88–92% · HSPF2 8.8 · 3 pairings

  65. 2065 SOV48H2BAInnovair
    47,000 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 40,000 Btu/h · Cold output 79–93% · HSPF2 8.8 · 4 pairings

  66. 2066 ASH4248UCDDGE
    48,000 Btu/hheating at 47°F 46,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Mini-split · 5°F 35,600 Btu/h · Cold output 74–82% · HSPF2 8.7 · 3 pairings

  67. 2067 YDC60E2D11York
    55,000 Btu/hheating at 47°F 52,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 47,000 Btu/h · Cold output 85–100% · HSPF2 8.5 · 7 pairings

  68. 2068 NTXSKH30A112AATrane / Mitsubishi Electric
    34,000 Btu/hheating at 47°F 27,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 32,000 Btu/h · Cold output 94% · HSPF2 8.5 · 2 pairings

  69. 2069 SUZ-KA30NAHZMitsubishi Electric
    34,000 Btu/hheating at 47°F 27,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 32,000 Btu/h · Cold output 94% · HSPF2 8.5 · 3 pairings

  70. 2070 AZPN/C36WDUIDKepler
    36,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 30,000 Btu/h · Cold output 83% · HSPF2 8.5 · 1 pairing

  71. 2071 DLCURAH36ACKMidea
    36,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 30,000 Btu/h · Cold output 83–97% · HSPF2 8.5 · 3 pairings

  72. 2072 MO1BE-H32B-2AMidea
    36,000 Btu/hheating at 47°F 32,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 26,400 Btu/h · Cold output 73–75% · HSPF2 8.5 · 5 pairings

  73. 36,000 Btu/hheating at 47°F 32,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 26,400 Btu/h · Cold output 73% · HSPF2 8.5 · 2 pairings

  74. 2074 E4HL5024A1000AAmerican Standard, Ameristar + 2 more
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 21,000 Btu/h · Cold output 71–88% · HSPF2 8.5 · 10 pairings

  75. 24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 21,000 Btu/h · Cold output 71–88% · HSPF2 8.5 · 12 pairings

  76. 2076 E4HL5018A1000AAmeristar, RunTru
    20,000 Btu/hheating at 47°F 20,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Central · 5°F 18,000 Btu/h · Cold output 90% · HSPF2 8.5 · 4 pairings

  77. 20,000 Btu/hheating at 47°F 20,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Central · 5°F 18,000 Btu/h · Cold output 89–90% · HSPF2 8.5 · 7 pairings

  78. 2078 37MURAQ60AA3Bryant, Carrier + 3 more
    54,000 Btu/hheating at 47°F 54,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Central · 5°F 38,000 Btu/h · Cold output 70% · HSPF2 8.4 · 5 pairings

  79. 2079 ACIQ-60-EHPD1HVAC, ACiQ
    54,000 Btu/hheating at 47°F 54,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Central · 5°F 38,000 Btu/h · Cold output 70% · HSPF2 8.4 · 2 pairings

  80. 2080 AHU19-60HN1-CApooDr, AproDr
    54,000 Btu/hheating at 47°F 54,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Central · 5°F 38,000 Btu/h · Cold output 70% · HSPF2 8.4 · 2 pairings

  81. 2081 MO1AE-H48B-2AMidea
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 33,600 Btu/h · Cold output 70% · HSPF2 8.4 · 2 pairings

  82. 48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 33,600 Btu/h · Cold output 70% · HSPF2 8.3 · 4 pairings

  83. 36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 30,000 Btu/h · Cold output 71–83% · HSPF2 8.3 · 2 pairings

  84. 2084 BNG1A48SCNBlueridge
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 33,600 Btu/h · Cold output 70% · HSPF2 8.2 · 1 pairing

  85. 2085 AC036FCUDCGSamsung
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 26,200 Btu/h · Cold output 73–74% · HSPF2 8.2 · 2 pairings

  86. 2086 5HPL5048A1American Standard, Trane
    46,000 Btu/hheating at 47°F 41,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 37,000 Btu/h · Cold output 79–80% · HSPF2 8.1 · 8 pairings

  87. 45,000 Btu/hheating at 47°F 41,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 37,000 Btu/h · Cold output 79–82% · HSPF2 8.1 · 22 pairings

  88. 2088 AC048FCUDCGSamsung
    48,000 Btu/hheating at 47°F 47,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 34,600 Btu/h · Cold output 72–80% · HSPF2 8.1 · 2 pairings

  89. 2089 E4HL5060A1000AAmeristar, RunTru
    45,000 Btu/hheating at 47°F 47,500 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 33,400 Btu/h · Cold output 74% · HSPF2 8.1 · 2 pairings

  90. 45,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 33,400 Btu/h · Cold output 74–83% · HSPF2 8.1 · 3 pairings

  91. 45,000 Btu/hheating at 47°F 47,500 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 33,400 Btu/h · Cold output 70–74% · HSPF2 8.1 · 6 pairings

  92. 2092 5HPL5036A1American Standard, Trane
    35,000 Btu/hheating at 47°F 33,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 30,000 Btu/h · Cold output 79–86% · HSPF2 8.1 · 44 pairings

  93. 24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 19,500 Btu/h · Cold output 72–81% · HSPF2 8.1 · 5 pairings

  94. 2094 5HPL5024A1American Standard, Trane
    22,000 Btu/hheating at 47°F 21,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Central · 5°F 19,000 Btu/h · Cold output 78–90% · HSPF2 8.1 · 60 pairings

  95. 2095 E4HL5030A1000AAmeristar, RunTru
    25,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 18,000 Btu/h · Cold output 72% · HSPF2 8.1 · 2 pairings

  96. 2096 E4HL5036A1000AAmeristar, RunTru
    25,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 18,000 Btu/h · Cold output 70–72% · HSPF2 8.1 · 12 pairings

  97. 25,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 18,000 Btu/h · Cold output 70–75% · HSPF2 8.1 · 15 pairings

New England Heat Pump Accelerator, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2)
# Model Brands Type Size At 5°FBtu/h · heating At 47°FBtu/h · heating At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed SEER2median pairing HSPF2Btu/Wh · median pairing Compressor Refrigerant Market Pairings
2001 PUZ-HA24NHA Mitsubishi Electric Mini-split 24,000 Btu (2-ton)25,400 25,400 24,000 89–100% 1.80 15.6 9.3 Variable R-410A US CA 3
2002 CU-HM30BAHU Panasonic Central 30,000 Btu (2.5-ton)29,000 29,000 29,000 96–107% 1.80 15.6 8.8 Variable R-454B US CA 13
2003 ACIQ-48-EHPD 1HVAC, ACiQ Central 42,000 Btu (3.5-ton)38,000 48,000 48,000 79–85% 1.85 15.6 8.8 Variable R-454B US CA 4
2004 BNG2A48SCN Blueridge Central 42,000 Btu (3.5-ton)38,000 48,000 48,000 79–85% 1.85 15.6 8.8 Variable R-454B US CA 2
2005 DRU1H30S2A DuraSTAR Central 30,000 Btu (2.5-ton)29,000 29,000 29,000 90–107% 1.75 15.6 8.7 Variable R-454B US CA 49
2006 MO1HE-H30B-2A Midea Central 30,000 Btu (2.5-ton)29,000 29,000 29,000 90–107% 1.75 15.6 8.7 Variable R-454B US CA 114
2007 CU-M36BAHU Panasonic Central 36,000 Btu (3-ton)26,000 36,000 35,000 72–75% 1.80 15.6 8.6 Variable R-454B US CA 4
2008 CCB1-H36A-O Capella Central 36,000 Btu (3-ton)34,000 36,000 35,000 89–105% 1.90 15.6 9.4 Variable R-454B US CA 6
2009 AUWR-48U3SP Hisense Central 42,000 Btu (3.5-ton)34,600 42,000 42,000 82% 1.94 15.6 8.6 Variable R-410A US CA 1
2010 TZID36H520ZCS Thermal Zone Central 36,000 Btu (3-ton)26,000 36,000 35,000 72–75% 1.80 15.6 8.5 Variable R-454B US CA 12
2011 DLCURAH36ABK Airquest, Arcoaire + 12 more Central 36,000 Btu (3-ton)32,000 39,000 35,000 82–86% 1.97 15.5 9.5 Variable R-410A US CA 48
2012 MOE31U-36HFN1-M Alsetria, CanAir + 4 more Central 36,000 Btu (3-ton)32,000 39,000 35,000 82–100% 1.97 15.5 9.5 Variable R-410A US CA 19
2013 AUWR-36U3SA Hisense Central 30,000 Btu (2.5-ton)24,200 30,000 30,000 81% 2.08 15.5 9.4 Variable R-410A US CA 1
2014 DRU1H36S2A DuraSTAR Central 36,000 Btu (3-ton)33,000 36,000 36,000 86–105% 1.80 15.5 9.3 Variable R-454B US CA 47
2015 MO1SE-H36B-2A Midea Central 36,000 Btu (3-ton)33,000 36,000 36,000 86–105% 1.80 15.5 9.3 Variable R-454B US CA 120
2016 BZ33-INV36OUT2-J Breeze33 Central 36,000 Btu (3-ton)32,000 39,000 35,000 82–88% 1.85 15.5 9.2 Variable R-410A US CA 3
2017 1824SPV0-HP-X-D Multi MFG Central 18,000 Btu (1.5-ton)12,800 16,800 16,800 76% 2.20 15.5 9.1 Variable R-454B US CA 1
2018 PUZ-HA42NKA1 Mitsubishi Electric, Trane / Mitsubishi Electric Mini-split 42,000 Btu (3.5-ton)48,000 54,000 42,000 89% 1.90 15.5 9.0 Variable R-410A US CA 7
2019 TRUZH0421KA10NA Trane / Mitsubishi Electric Mini-split 42,000 Btu (3.5-ton)48,000 54,000 42,000 89% 1.90 15.5 9.0 Variable R-410A US 3
2020 BZ33-INV30OUT2-J Breeze33 Central 30,000 Btu (2.5-ton)25,000 31,000 30,000 73–82% 1.80 15.5 9.0 Variable R-410A US CA 3
2021 37MUHAQ48AA3 Bryant, Carrier + 3 more Central 48,000 Btu (4-ton)46,000 50,000 48,000 88–100% 1.85 15.5 8.8 Variable R-454B US CA 31
2022 D5CUHAH48AAK Airquest, Arcoaire + 11 more Central 48,000 Btu (4-ton)46,000 50,000 48,000 88–100% 1.85 15.5 8.8 Variable R-454B US CA 55
2023 MVP-60-HP-C-230A00-O MRCOOL Central 48,000 Btu (4-ton)40,000 48,000 51,000 70–83% 1.80 15.5 8.6 Variable R-454B US CA 3
2024 BOHA-60RTB-M18S Bosch Central 54,000 Btu (4.5-ton)39,000 48,000 48,000 69–81% 1.90 15.5 8.6 Variable R-454B US CA 19
2025 AZPN/36WAC Kepler Central 36,000 Btu (3-ton)31,600 38,000 35,000 83% 1.85 15.5 8.6 Variable R-410A US CA 1
2026 25SPV0-HP-X-D Multi MFG Central 24,000 Btu (2-ton)18,900 25,000 25,000 76% 2.10 15.5 8.6 Variable R-454B US CA 1
2027 UHP18048-O MRCOOL Central 42,000 Btu (3.5-ton)42,000 48,000 45,000 87–100% 1.80 15.5 8.5 Variable R-454B US CA 5
2028 CENTRAL-48-HP-C-230B00-O MRCOOL Central 42,000 Btu (3.5-ton)41,000 47,000 45,000 87–92% 1.80 15.5 8.5 Variable R-454B US CA 8
2029 37MURAQ48AA3 Bryant, Carrier + 3 more Central 48,000 Btu (4-ton)38,000 48,000 48,000 77–85% 1.85 15.5 8.5 Variable R-454B US CA 17
2030 MO1BE-H60B-2A Midea Central 48,000 Btu (4-ton)38,000 47,000 51,000 70–83% 1.80 15.5 8.5 Variable R-454B US CA 21
2031 37MUHAQ36AA3 Bryant, Carrier + 3 more Central 36,000 Btu (3-ton)30,400 38,000 35,600 78–105% 1.80 15.5 8.5 Variable R-454B US CA 1,186
2032 D5CUHAH36AAK Airquest, Arcoaire + 15 more Central 36,000 Btu (3-ton)30,400 38,000 35,600 78–105% 1.80 15.5 8.5 Variable R-454B US CA 2,634
2033 27VPA936A*030* Carrier CentralCold climate on some pairings 36,000 Btu (3-ton)25,600 36,200 34,400 67–82% 2.05 15.5 8.5 Variable R-454B US CA 497
2034 D5CURAH24AAK Airquest, Arcoaire + 15 more Central 24,000 Btu (2-ton)19,300 24,000 23,600 76–83% 1.94 15.5 8.5 Variable R-454B US CA 1,095
2035 D5CUHAH18AAK Airquest, Arcoaire + 15 more Central 18,000 Btu (1.5-ton)16,800 19,800 17,700 83–103% 1.92 15.5 8.5 Variable R-454B US CA 591
2036 SPHP-Z-V037BB AC Pro Central 36,000 Btu (3-ton)36,000 37,000 36,000 97% 1.90 15.4 9.8 Variable R-454B US CA 1
2037 MOX430U-22HFN1-MR0 MDV Central 24,000 Btu (2-ton)16,000 22,000 22,000 73% 2.00 15.4 9.2 Variable R-410A US CA 1
2038 PUZ-HA42NKA Mitsubishi Electric Mini-split 42,000 Btu (3.5-ton)48,000 54,000 42,000 89% 1.95 15.4 8.9 Variable R-410A US CA 1
2039 MVP-48-HP-C-230A00-O MRCOOL Central 42,000 Btu (3.5-ton)40,000 47,000 45,000 79–93% 1.80 15.4 8.9 Variable R-454B US CA 8
2040 SPHP-Y-V036BB AC Pro Central 36,000 Btu (3-ton)27,000 36,000 36,000 72–77% 1.90 15.4 8.7 Variable R-454B US CA 3
2041 MO1BE-H36B-2A Midea Central 36,000 Btu (3-ton)26,000 36,000 36,000 72–79% 1.86 15.4 8.4 Variable R-454B US CA 29
2042 MVP-36-HP-C-230A00-O MRCOOL Central 36,000 Btu (3-ton)26,000 36,000 36,000 72–75% 1.90 15.4 8.2 Variable R-454B US CA 3
2043 TZPLV482PA Thermal Zone Central 42,000 Btu (3.5-ton)46,000 50,000 47,000 85–92% 1.85 15.4 9.3 Variable R-410A US CA 2
2044 AVE09N3H1 Ephoca, Innova Central 6,000 Btu6,400 8,200 7,500 78% 1.75 15.4 9.9 Variable R-32 US CA 2
2045 DIRM4-48MAGICPRO20-OU Direct Air Central 42,000 Btu (3.5-ton)42,000 48,000 45,000 87–92% 1.83 15.4 8.7 Variable R-454B US CA 4
2046 MSHMB36R2AN MoovAir Central 36,000 Btu (3-ton)34,000 38,000 36,000 89–92% 1.80 15.3 9.6 Variable R-454B US CA 2
2047 DLCURAH60ABK Airquest, Arcoaire + 12 more Central 54,000 Btu (4.5-ton)48,500 59,000 55,000 82% 1.91 15.3 9.4 Variable R-410A US CA 22
2048 CENTRAL-36-HP-C-230B00-O MRCOOL Central 36,000 Btu (3-ton)33,000 37,000 36,000 87–105% 1.80 15.3 9.2 Variable R-454B US CA 21
2049 ACK09N3H1 Ephoca, Innova Central 6,000 Btu5,900 8,200 6,100 72% 1.75 15.3 9.2 Variable R-32 US CA 2
2050 MDV-V30WMN10T-H Midea Central 30,000 Btu (2.5-ton)26,000 30,000 30,000 87% 1.80 15.3 8.5 Variable R-454B US CA 1
2051 MDV-V24WMN10T-H Midea Central 24,000 Btu (2-ton)19,400 24,000 23,000 81% 1.80 15.3 8.5 Variable R-454B US CA 1
2052 AC048FCUPCG Samsung Central 42,000 Btu (3.5-ton)39,500 48,000 45,000 75–84% 1.95 15.3 8.2 2-stage R-454B US CA 7
2053 DIRM-60MAGICPRO20-OU Direct Air Central 42,000 Btu (3.5-ton)46,500 55,000 45,000 82–85% 1.86 15.3 9.3 Variable R-410A US CA 2
2054 MHSD136DACFC Conforto, EMI Central 36,000 Btu (3-ton)32,000 39,000 35,000 82–86% 2.00 15.2 10.0 Variable R-410A US CA 6
2055 MHD-24 Dettson, Innovair Central 24,000 Btu (2-ton)23,000 24,600 23,000 93% 2.08 15.2 9.8 Variable R-410A US CA 2
2056 MHD-18 Dettson, Innovair Central 18,000 Btu (1.5-ton)14,600 19,500 18,000 75% 2.20 15.2 9.5 Variable R-410A US CA 2
2057 SUZ-KA36NAHZ Mitsubishi Electric Mini-split 30,000 Btu (2.5-ton)38,000 40,000 33,000 95% 1.75 15.2 9.3 Variable R-410A US CA 1
2058 MOE30U-45HFN1-M Alsetria, Eco Air, MDV Central 42,000 Btu (3.5-ton)46,500 55,000 45,000 85% 1.80 15.2 9.2 Variable R-410A US CA 3
2059 5HCL6036A1000A Trane/American Standard Central 36,000 Btu (3-ton)37,000 40,000 36,000 93% 1.80 15.2 9.1 Variable R-454B US 1
2060 WSCHV0048BA1-C Continental Central 42,000 Btu (3.5-ton)40,000 47,000 45,000 85% 1.85 15.2 9.0 Variable R-454B US CA 1
2061 YDV36E2D11 York Central 24,000 Btu (2-ton)23,800 34,000 32,000 70–73% 1.90 15.2 9.0 Variable R-454B US CA 7
2062 9SPV0-HP-X-D Multi MFG Central 9,000 Btu8,000 9,000 9,000 89% 2.30 15.2 8.9 Variable R-454B US 1
2063 A-KXP48TA-1 Kerr Central 42,000 Btu (3.5-ton)42,000 48,000 45,000 88% 1.85 15.2 8.8 Variable R-454B US CA 1
2064 CCB1-H48A-O Capella Central 42,000 Btu (3.5-ton)42,000 48,000 45,000 88–92% 1.85 15.2 8.8 Variable R-454B US CA 3
2065 SOV48H2BA Innovair Central 42,000 Btu (3.5-ton)40,000 47,000 45,000 79–93% 1.83 15.2 8.8 Variable R-454B US CA 4
2066 ASH4248UCDD GE Mini-split 42,000 Btu (3.5-ton)35,600 48,000 46,000 74–82% 1.75 15.2 8.7 Variable R-410A US CA 3
2067 YDC60E2D11 York Central 42,000 Btu (3.5-ton)47,000 55,000 52,000 85–100% 1.80 15.2 8.5 Variable R-454B US CA 7
2068 NTXSKH30A112AA Trane / Mitsubishi Electric Mini-split 24,000 Btu (2-ton)32,000 34,000 27,000 94% 1.75 15.2 8.5 Variable R-410A US 2
2069 SUZ-KA30NAHZ Mitsubishi Electric Mini-split 24,000 Btu (2-ton)32,000 34,000 27,000 94% 1.75 15.2 8.5 Variable R-410A US CA 3
2070 AZPN/C36WDUID Kepler Central 36,000 Btu (3-ton)30,000 36,000 35,000 83% 1.80 15.2 8.5 Variable R-410A US CA 1
2071 DLCURAH36ACK Midea Central 36,000 Btu (3-ton)30,000 36,000 35,000 83–97% 1.80 15.2 8.5 Variable R-410A US CA 3
2072 MO1BE-H32B-2A Midea Central 30,000 Btu (2.5-ton)26,400 36,000 32,000 73–75% 2.00 15.2 8.5 Variable R-454B US CA 5
2073 MOD30-32HFN10-M3 MDV Central 30,000 Btu (2.5-ton)26,400 36,000 32,000 73% 2.00 15.2 8.5 Variable R-454B US CA 2
2074 E4HL5024A1000A American Standard, Ameristar + 2 more Central 24,000 Btu (2-ton)21,000 24,000 24,000 71–88% 1.85 15.2 8.5 Variable R-410A US CA 10
2075 THH24HAI2NAF2U23 TCL Central 24,000 Btu (2-ton)21,000 24,000 24,000 71–88% 1.85 15.2 8.5 Variable R-410A US CA 12
2076 E4HL5018A1000A Ameristar, RunTru Central 18,000 Btu (1.5-ton)18,000 20,000 20,000 90% 1.85 15.2 8.5 Variable R-410A US CA 4
2077 THH18HAI2NAF2U23 TCL Central 18,000 Btu (1.5-ton)18,000 20,000 20,000 89–90% 1.85 15.2 8.5 Variable R-410A US CA 7
2078 37MURAQ60AA3 Bryant, Carrier + 3 more Central 54,000 Btu (4.5-ton)38,000 54,000 54,000 70% 1.80 15.2 8.4 Variable R-454B US CA 5
2079 ACIQ-60-EHPD 1HVAC, ACiQ Central 54,000 Btu (4.5-ton)38,000 54,000 54,000 70% 1.80 15.2 8.4 Variable R-454B US CA 2
2080 AHU19-60HN1-C ApooDr, AproDr Central 54,000 Btu (4.5-ton)38,000 54,000 54,000 70% 1.80 15.2 8.4 Variable R-454B US CA 2
2081 MO1AE-H48B-2A Midea Central 48,000 Btu (4-ton)33,600 48,000 48,000 70% 1.85 15.2 8.4 Variable R-454B US CA 2
2082 MOD30-48HFN10-M3F MDV Central 48,000 Btu (4-ton)33,600 48,000 48,000 70% 1.85 15.2 8.3 Variable R-454B US CA 4
2083 THH48HAI2NAF2U23 TCL Central 36,000 Btu (3-ton)30,000 36,000 36,000 71–83% 1.78 15.2 8.3 Variable R-410A US CA 2
2084 BNG1A48SCN Blueridge Central 48,000 Btu (4-ton)33,600 48,000 48,000 70% 1.85 15.2 8.2 Variable R-454B US CA 1
2085 AC036FCUDCG Samsung Central 36,000 Btu (3-ton)26,200 36,000 36,000 73–74% 1.88 15.2 8.2 2-stage R-454B US CA 2
2086 5HPL5048A1 American Standard, Trane Central 42,000 Btu (3.5-ton)37,000 46,000 41,000 79–80% 1.80 15.2 8.1 2-stage R-454B US CA 8
2087 THH48HES2NAGOH24 TCL Central 42,000 Btu (3.5-ton)37,000 45,000 41,000 79–82% 1.80 15.2 8.1 2-stage R-454B US CA 22
2088 AC048FCUDCG Samsung Central 48,000 Btu (4-ton)34,600 48,000 47,000 72–80% 1.91 15.2 8.1 2-stage R-454B US CA 2
2089 E4HL5060A1000A Ameristar, RunTru Central 48,000 Btu (4-ton)33,400 45,000 47,500 74% 1.75 15.2 8.1 Variable R-410A US CA 2
2090 THH42HAI2NAF2U23 TCL Central 36,000 Btu (3-ton)33,400 45,000 48,000 74–83% 1.75 15.2 8.1 Variable R-410A US CA 3
2091 THH60HAI2NAF2U23 TCL Central 48,000 Btu (4-ton)33,400 45,000 47,500 70–74% 1.75 15.2 8.1 Variable R-410A US CA 6
2092 5HPL5036A1 American Standard, Trane Central 30,000 Btu (2.5-ton)30,000 35,000 33,000 79–86% 1.80 15.2 8.1 2-stage R-454B US CA 44
2093 THH30HAI2NAF2U23 TCL Central 30,000 Btu (2.5-ton)19,500 24,000 24,000 72–81% 1.75 15.2 8.1 Variable R-410A US CA 5
2094 5HPL5024A1 American Standard, Trane Central 18,000 Btu (1.5-ton)19,000 22,000 21,000 78–90% 1.80 15.2 8.1 2-stage R-454B US CA 60
2095 E4HL5030A1000A Ameristar, RunTru Central 30,000 Btu (2.5-ton)18,000 25,000 30,000 72% 1.75 15.2 8.1 Variable R-410A US CA 2
2096 E4HL5036A1000A Ameristar, RunTru Central 30,000 Btu (2.5-ton)18,000 25,000 30,000 70–72% 1.75 15.2 8.1 Variable R-410A US CA 12
2097 THH36HAI2NAF2U23 TCL Central 30,000 Btu (2.5-ton)18,000 25,000 30,000 70–75% 1.75 15.2 8.1 Variable R-410A US CA 15

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

97 of 2,097 units · page 11 of 11

Program specifications

Program specifications
Instant discount$650 per outdoor unit, up to two per home
RegionConnecticut, Massachusetts, New Hampshire, and Rhode Island, United States
StatusOpen
Program pageThe program's own page
Qualified product listNamed on the program's own page
CheckedSep 28, 2026

Efficiency thresholds

Efficiency thresholds
RequirementMini-splitCentral
SEER2median certified pairing15.2 or more15.2 or more
HSPF2median certified pairing8.5 or more8.1 or more
COP at 5°Fmedian certified pairing, full-speed test1.75 or more1.75 or more
Heat at 5°F as a share of the 47°F ratingmedian certified pairing70% or more70% or more
Cold-climate designationEPA designationOn at least one certified pairingOn at least one certified pairing
ENERGY STAREvery unit in our data is ENERGY STAR certified.

The ENERGY STAR cold-climate criteria the program publishes.

Other programs in Connecticut

Every heat pump rebate program

Excluded from this program

The program also requires purchase through a participating distributor and an existing home. The unit list does not check these.

112 units have no certified COP at 5°F figure and are not listed.

115 units have no certified heat output at 5°F figure and are not listed.