Heat Pump List

Tools

Airquest, Arcoaire +14 more: shared model numbers

710 certified models, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2), highest first.

Filters

Filters Airquest, Arcoaire +14 more

The list

  1. 1 37MPRAQ06AA3Bryant, Carrier + 3 more
    9,000 Btu/hheating at 47°F 6,000 Btu/hcooling at 95°F

    6,000 Btu · Mini-split · 5°F 13,500 Btu/h · Cold output 150% · HSPF2 15.6 · 7 pairings

  2. 2 MO1SS-H06B-2AMidea
    9,000 Btu/hheating at 47°F 6,000 Btu/hcooling at 95°F

    6,000 Btu · Mini-split · 5°F 13,500 Btu/h · Cold output 150% · HSPF2 15.6 · 1 pairing

  3. 3 37MPRAQ09AA3Bryant, Carrier + 3 more
    12,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 13,500 Btu/h · Cold output 113% · HSPF2 14.6 · 7 pairings

  4. 4 MO1SS-H09B-2AMidea
    12,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 13,500 Btu/h · Cold output 113% · HSPF2 14.6 · 1 pairing

  5. 5 D5CPRAH06AAKAirquest, Arcoaire + 9 more
    9,000 Btu/hheating at 47°F 6,000 Btu/hcooling at 95°F

    6,000 Btu · Mini-split · 5°F 13,500 Btu/h · Cold output 150% · HSPF2 15.6 · 11 pairings

  6. 6 D5CPRAH09AAKAirquest, Arcoaire + 9 more
    12,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 13,500 Btu/h · Cold output 113% · HSPF2 14.6 · 11 pairings

  7. 7 37MPRAQ12AA3Bryant, Carrier + 3 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 13,500 Btu/h · Cold output 113% · HSPF2 12.7 · 7 pairings

  8. 8 MO1SS-H12B-2AMidea
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 13,500 Btu/h · Cold output 113% · HSPF2 12.7 · 1 pairing

  9. 9 MOX430-09HFN1-MZG5WMDV, Midea
    12,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 13,700 Btu/h · Cold output 100–114% · HSPF2 12.0 · 5 pairings

  10. 10 D5CPRAH12AAKAirquest, Arcoaire + 9 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 13,500 Btu/h · Cold output 113% · HSPF2 12.7 · 11 pairings

  11. 11 DLCPRBH09AAKAirquest, Arcoaire + 10 more
    12,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 13,700 Btu/h · Cold output 100–114% · HSPF2 15.0 · 29 pairings

  12. 12 38MPRBQ09AA3Bryant, Carrier + 3 more
    12,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 13,700 Btu/h · Cold output 100–114% · HSPF2 12.0 · 12 pairings

  13. 13 38MPRBQ12AA3Bryant, Carrier + 3 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 13,700 Btu/h · Cold output 100–114% · HSPF2 12.0 · 12 pairings

  14. 14 MOX430-12HFN1-MZ60WMDV, Midea
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 13,700 Btu/h · Cold output 100–114% · HSPF2 12.0 · 5 pairings

  15. 15 38MPRBQ18AA3Bryant, Carrier + 3 more
    20,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 24,000 Btu/h · Cold output 120% · HSPF2 11.0 · 5 pairings

  16. 16 DLCPRBH18AAKAirquest, Arcoaire + 10 more
    20,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 24,000 Btu/h · Cold output 120% · HSPF2 11.0 · 16 pairings

  17. 17 37MPRAQ18AA3Bryant, Carrier + 3 more
    20,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 22,600 Btu/h · Cold output 113% · HSPF2 16.2 · 7 pairings

  18. 18 MO1SS-H18B-2AMidea
    20,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 22,600 Btu/h · Cold output 113% · HSPF2 16.2 · 1 pairing

  19. 19 MOX3-12HFN10AEMidea
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,400 Btu/h · Cold output 70% · HSPF2 10.6 · 1 pairing

  20. 20 MO1ES-H09B-1AMidea
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,200 Btu/h · Cold output 72% · HSPF2 10.0 · 2 pairings

  21. 21 DLCPRBH12AAKAirquest, Arcoaire + 10 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 13,700 Btu/h · Cold output 100–114% · HSPF2 11.7 · 30 pairings

  22. 22 MO4EX-H27B-2BMidea
    27,000 Btu/hheating at 47°F 27,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 19,000 Btu/h · Cold output 70% · HSPF2 9.5 · 1 pairing

  23. 23 M4OD30-24HFN10-M1DArctic King, MDV, Midea
    25,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 72% · HSPF2 9.5 · 5 pairings

  24. 24 D5CPRAH18AAAirquest, Arcoaire + 9 more
    20,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 22,600 Btu/h · Cold output 113% · HSPF2 15.2 · 11 pairings

  25. 25 MOX230-09HFN1-BW0WMDV, Midea
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 6,700 Btu/h · Cold output 65–68% · HSPF2 9.9 · 4 pairings

  26. 26 38MARBQ06AA3Bryant, Carrier + 3 more
    7,000 Btu/hheating at 47°F 6,000 Btu/hcooling at 95°F

    6,000 Btu · Mini-split · 5°F 7,500 Btu/h · Cold output 107–113% · HSPF2 12.2 · 10 pairings

  27. 27 37MAHAQ09AA3Bryant, Carrier + 3 more
    9,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 11,300 Btu/h · Cold output 96–126% · HSPF2 12.5 · 32 pairings

  28. 28 DLCSRBH09AAKAirquest, Arcoaire + 12 more
    12,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 10,600 Btu/h · Cold output 88–110% · HSPF2 11.6 · 99 pairings

  29. 29 MOX430-18HFN1-MT8WMDV, Midea
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,800 Btu/h · Cold output 71% · HSPF2 10.5 · 2 pairings

  30. 30 38MARBQ12AA3Bryant, Carrier + 3 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 11,900 Btu/h · Cold output 83–100% · HSPF2 10.0 · 41 pairings

  31. 31 DLCSRBH06AAKAirquest, Arcoaire + 12 more
    7,000 Btu/hheating at 47°F 6,000 Btu/hcooling at 95°F

    6,000 Btu · Mini-split · 5°F 7,500 Btu/h · Cold output 101–113% · HSPF2 12.0 · 48 pairings

  32. 32 MOX4-18HFN10AEMidea
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,800 Btu/h · Cold output 71% · HSPF2 10.8 · 1 pairing

  33. 33 MOX4-18HFN1AAMidea
    19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 11,300 Btu/h · Cold output 59% · HSPF2 10.8 · 1 pairing

  34. 34 38MARBQ12AA1Bryant, Carrier + 3 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 6,800 Btu/h · Cold output 57% · HSPF2 10.0 · 5 pairings

  35. 35 DLCSRBH12AAJAirquest, Arcoaire + 12 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 6,800 Btu/h · Cold output 56–57% · HSPF2 10.0 · 35 pairings

  36. 36 MO1ES-H15B-2AMidea
    15,000 Btu/hheating at 47°F 15,000 Btu/hcooling at 95°F

    15,000 Btu · Mini-split · 5°F 11,500 Btu/h · Cold output 77% · HSPF2 9.9 · 1 pairing

  37. 37 37MARAQ12AA1Bryant, Carrier + 3 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 7,700 Btu/h · Cold output 64% · HSPF2 9.5 · 7 pairings

  38. 38 D5CSRAH12AAJAirquest, Arcoaire + 10 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 7,700 Btu/h · Cold output 64% · HSPF2 9.5 · 12 pairings

  39. 39 MO1ES-H12B-1AMidea
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 7,700 Btu/h · Cold output 64% · HSPF2 9.5 · 2 pairings

  40. 40 D5CSHAH09AAKAirquest, Arcoaire + 10 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 11,200 Btu/h · Cold output 96–126% · HSPF2 12.4 · 72 pairings

  41. 41 MO1HS-H09B-2AMidea
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 11,200 Btu/h · Cold output 96–126% · HSPF2 12.3 · 6 pairings

  42. 42 DLCSRBH12AAKAirquest, Arcoaire + 12 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 12,000 Btu/h · Cold output 88–100% · HSPF2 10.2 · 110 pairings

  43. 43 MOD-24HFN10AEMidea
    25,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 19,600 Btu/h · Cold output 78% · HSPF2 11.7 · 1 pairing

  44. 44 37MAHAQ12AA3Bryant, Carrier + 3 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 11,500 Btu/h · Cold output 92–100% · HSPF2 10.5 · 32 pairings

  45. 45 MOX330-12HFN1-MW5WAlsetria, Eco Air + 2 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 11,900 Btu/h · Cold output 83–100% · HSPF2 10.1 · 20 pairings

  46. 10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 6,700 Btu/h · Cold output 67% · HSPF2 9.8 · 1 pairing

  47. 47 37MGRAQ30EA3Bryant, Carrier + 3 more
    31,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 25,400 Btu/h · Cold output 81–84% · HSPF2 9.8 · 15 pairings

  48. 48 D5CMRAH30EAKAirquest, Arcoaire + 9 more

    Same as 37MGRAQ30EA3

    31,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 25,400 Btu/h · Cold output 81–84% · HSPF2 9.8 · 33 pairings

  49. 49 38MGHBQ30DA3Bryant, Carrier + 3 more
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 24,600 Btu/h · Cold output 80–84% · HSPF2 9.5 · 15 pairings

  50. 50 MMCMHAQ30DA3Midea

    Same as 38MGHBQ30DA3

    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 24,600 Btu/h · Cold output 80–84% · HSPF2 9.5 · 3 pairings

  51. 51 37MGRAQ24DA3Bryant, Carrier + 3 more
    25,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 72% · HSPF2 9.5 · 15 pairings

  52. 52 D5CMRAH24DAKAirquest, Arcoaire + 9 more

    Same as 37MGRAQ24DA3

    25,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 72% · HSPF2 9.5 · 33 pairings

  53. 26,800 Btu/hheating at 47°F 26,800 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,900 Btu/h · Cold output 70–71% · HSPF2 9.3 · 3 pairings

  54. 54 MO4DX-H27B-2AMidea
    26,800 Btu/hheating at 47°F 26,800 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,900 Btu/h · Cold output 70–71% · HSPF2 9.3 · 3 pairings

  55. 55 MO4EX-H27B-2AMidea
    26,800 Btu/hheating at 47°F 26,800 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,900 Btu/h · Cold output 70–71% · HSPF2 9.3 · 3 pairings

  56. 56 38MGHBQ24CA3Bryant, Carrier + 3 more
    24,400 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,200 Btu/h · Cold output 74–75% · HSPF2 9.9 · 18 pairings

  57. 57 MMCMHAQ24CA3Midea

    Same as 38MGHBQ24CA3

    24,400 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,200 Btu/h · Cold output 74–75% · HSPF2 9.9 · 3 pairings

  58. 58 MOX230-12HFN1-MV5WAlsetria, Eco Air + 2 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,100 Btu/h · Cold output 62–70% · HSPF2 10.3 · 20 pairings

  59. 59 MOX230-12HFN1-BW0WMDV, Midea
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 6,700 Btu/h · Cold output 47–57% · HSPF2 10.0 · 5 pairings

  60. 60 38MGRBQ48EA3Bryant, Carrier + 3 more
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 33,000 Btu/h · Cold output 67–69% · HSPF2 9.0 · 10 pairings

  61. 61 MMCMRAQ48EA3Midea

    Same as 38MGRBQ48EA3

    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 33,000 Btu/h · Cold output 67–69% · HSPF2 9.0 · 2 pairings

  62. 62 D5CSHAH12AAKAirquest, Arcoaire + 10 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 11,500 Btu/h · Cold output 92–100% · HSPF2 10.6 · 72 pairings

  63. 63 MO1HS-H12B-2AMidea
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 11,500 Btu/h · Cold output 92–100% · HSPF2 10.5 · 6 pairings

  64. 64 37MGRAQ18CA3Bryant, Carrier + 3 more
    19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 14,000 Btu/h · Cold output 71–77% · HSPF2 9.9 · 15 pairings

  65. 65 D5CMRAH18CAKAirquest, Arcoaire + 9 more

    Same as 37MGRAQ18CA3

    19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 14,000 Btu/h · Cold output 71–77% · HSPF2 9.9 · 33 pairings

  66. 19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 14,000 Btu/h · Cold output 71–77% · HSPF2 9.9 · 3 pairings

  67. 67 MO3EX-H18B-2AMidea
    19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 14,000 Btu/h · Cold output 71–77% · HSPF2 9.9 · 3 pairings

  68. 68 MOX230-09HFN1-MW5WAlsetria, Eco Air + 2 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,500 Btu/h · Cold output 70–113% · HSPF2 11.4 · 23 pairings

  69. 69 37MGRAQ48FA3Bryant, Carrier + 3 more
    47,500 Btu/hheating at 47°F 46,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 75–81% · HSPF2 10.5 · 15 pairings

  70. 70 D5CMRAH48FAKAirquest, Arcoaire + 9 more

    Same as 37MGRAQ48FA3

    47,500 Btu/hheating at 47°F 46,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 75–81% · HSPF2 10.5 · 33 pairings

  71. 71 37MGHAQ18CA3Bryant, Carrier + 3 more
    20,000 Btu/hheating at 47°F 19,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,500 Btu/h · Cold output 90–95% · HSPF2 10.3 · 15 pairings

  72. 72 D5CMHAH18CAKAirquest, Arcoaire + 10 more

    Same as 37MGHAQ18CA3

    20,000 Btu/hheating at 47°F 19,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,500 Btu/h · Cold output 90–95% · HSPF2 10.3 · 36 pairings

  73. 73 MO3GX-H18B-2AMidea
    20,000 Btu/hheating at 47°F 19,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,500 Btu/h · Cold output 90–95% · HSPF2 10.2 · 3 pairings

  74. 74 MO3HX-H18B-2AMidea

    Same as MO3GX-H18B-2A

    20,000 Btu/hheating at 47°F 19,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,500 Btu/h · Cold output 90–95% · HSPF2 10.2 · 3 pairings

  75. 75 37MHRAQ30AA3Bryant, Carrier + 3 more
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 20,000 Btu/h · Cold output 67% · HSPF2 9.0 · 5 pairings

  76. 76 D5CERAH30AAKAirquest, Arcoaire + 9 more
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 20,000 Btu/h · Cold output 67% · HSPF2 9.0 · 11 pairings

  77. 77 37MARAQ18AA3Bryant, Carrier + 3 more
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 13,000 Btu/h · Cold output 70–77% · HSPF2 10.8 · 42 pairings

  78. 78 38MARBQ09AA3Bryant, Carrier + 3 more
    10,900 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 10,500 Btu/h · Cold output 85–110% · HSPF2 11.3 · 30 pairings

  79. 79 M3OJ-27HFN1-MAlsetria, Eco Air + 2 more
    28,000 Btu/hheating at 47°F 28,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 18,800 Btu/h · Cold output 61–68% · HSPF2 9.2 · 18 pairings

  80. 28,000 Btu/hheating at 47°F 27,400 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 18,800 Btu/h · Cold output 67–68% · HSPF2 9.2 · 3 pairings

  81. 81 37MARAQ09AA3Bryant, Carrier + 3 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 8,300 Btu/h · Cold output 73–96% · HSPF2 11.8 · 32 pairings

  82. 82 MO1HS-H15B-2AMidea
    15,400 Btu/hheating at 47°F 15,400 Btu/hcooling at 95°F

    15,000 Btu · Mini-split · 5°F 17,500 Btu/h · Cold output 114% · HSPF2 11.5 · 1 pairing

  83. 83 37MARAQ12AA3Bryant, Carrier + 3 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,600 Btu/h · Cold output 70–74% · HSPF2 10.5 · 32 pairings

  84. 47,500 Btu/hheating at 47°F 46,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 75–81% · HSPF2 10.5 · 3 pairings

  85. 85 MO6EX-H48B-2AMidea
    47,500 Btu/hheating at 47°F 46,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 75–81% · HSPF2 10.5 · 3 pairings

  86. 86 37MAHAQ06AA3Bryant, Carrier + 3 more
    8,000 Btu/hheating at 47°F 6,500 Btu/hcooling at 95°F

    6,000 Btu · Mini-split · 5°F 7,800 Btu/h · Cold output 98–110% · HSPF2 13.8 · 17 pairings

  87. 87 D5CSHAH06AAKAirquest, Arcoaire + 10 more
    8,000 Btu/hheating at 47°F 6,500 Btu/hcooling at 95°F

    6,000 Btu · Mini-split · 5°F 7,800 Btu/h · Cold output 98–110% · HSPF2 13.8 · 35 pairings

  88. 88 MO1HS-H06B-2AMidea
    8,000 Btu/hheating at 47°F 6,500 Btu/hcooling at 95°F

    6,000 Btu · Mini-split · 5°F 7,800 Btu/h · Cold output 98–110% · HSPF2 13.8 · 3 pairings

  89. 89 MOD-24HFN1AAMidea
    25,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 15,500 Btu/h · Cold output 62% · HSPF2 10.0 · 1 pairing

  90. 90 37MGHAQ24DA3Bryant, Carrier + 3 more
    25,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 25,000 Btu/h · Cold output 100% · HSPF2 9.8 · 15 pairings

  91. 91 D5CMHAH24DAKAirquest, Arcoaire + 10 more

    Same as 37MGHAQ24DA3

    25,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 25,000 Btu/h · Cold output 100% · HSPF2 9.8 · 36 pairings

  92. 92 37MGRAQ36EA3Bryant, Carrier + 3 more
    37,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 26,000 Btu/h · Cold output 70% · HSPF2 9.4 · 15 pairings

  93. 93 D5CMRAH36EAKAirquest, Arcoaire + 9 more

    Same as 37MGRAQ36EA3

    37,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 26,000 Btu/h · Cold output 70% · HSPF2 9.4 · 33 pairings

  94. Same as 37MGRAQ36EA3

    37,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 26,000 Btu/h · Cold output 70% · HSPF2 9.4 · 3 pairings

  95. 95 MO5DX-H36B-2AMidea

    Same as 37MGRAQ36EA3

    37,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 26,000 Btu/h · Cold output 70% · HSPF2 9.4 · 3 pairings

  96. 96 MO5EX-H36B-2AMidea

    Same as 37MGRAQ36EA3

    37,000 Btu/hheating at 47°F 35,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 26,000 Btu/h · Cold output 70% · HSPF2 9.4 · 3 pairings

  97. 97 D5CSRAH09AAKAirquest, Arcoaire + 9 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 8,300 Btu/h · Cold output 73–96% · HSPF2 11.7 · 66 pairings

  98. 98 38MGRBQ36DA3Bryant, Carrier + 3 more
    37,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 24,600 Btu/h · Cold output 65–68% · HSPF2 9.4 · 15 pairings

  99. 99 M4OG-36HFN1-MAlsetria, Eco Air + 2 more

    Same as 38MGRBQ36DA3

    37,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 24,600 Btu/h · Cold output 65–68% · HSPF2 9.4 · 14 pairings

  100. 100 MMCMRAQ36DA3Midea

    Same as 38MGRBQ36DA3

    37,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 24,600 Btu/h · Cold output 65–68% · HSPF2 9.4 · 3 pairings

  101. 101 M5OG-48HFN1-MAlsetria, Eco Air + 2 more
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 33,000 Btu/h · Cold output 67–71% · HSPF2 9.0 · 10 pairings

  102. 102 MO1ES-H09B-2AMidea
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 8,300 Btu/h · Cold output 73–96% · HSPF2 11.7 · 6 pairings

  103. 103 M3OJ-24HFN1-MMDV, Midea
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 71–75% · HSPF2 9.7 · 9 pairings

  104. 104 DLCMHBH24CAKAirquest, Arcoaire + 10 more
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 17,500 Btu/h · Cold output 71–75% · HSPF2 9.7 · 38 pairings

  105. 105 37MGHAQ48FA3Bryant, Carrier + 3 more
    48,500 Btu/hheating at 47°F 47,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 47,500 Btu/h · Cold output 96–100% · HSPF2 11.2 · 15 pairings

  106. 106 D5CMHAH48FAKAirquest, Arcoaire + 10 more

    Same as 37MGHAQ48FA3

    48,500 Btu/hheating at 47°F 47,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 47,500 Btu/h · Cold output 96–100% · HSPF2 11.2 · 36 pairings

  107. 107 37MGHAQ30EA3Bryant, Carrier + 3 more
    31,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 36,000 Btu/h · Cold output 116% · HSPF2 10.6 · 15 pairings

  108. 108 D5CMHAH30EAKAirquest, Arcoaire + 10 more

    Same as 37MGHAQ30EA3

    31,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 36,000 Btu/h · Cold output 116% · HSPF2 10.6 · 36 pairings

  109. 109 MO6HX-H48B-2AMidea
    48,500 Btu/hheating at 47°F 47,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 47,500 Btu/h · Cold output 96–100% · HSPF2 11.0 · 3 pairings

  110. 110 D5CSRAH12AAKAirquest, Arcoaire + 9 more
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,600 Btu/h · Cold output 70–74% · HSPF2 10.5 · 66 pairings

  111. 111 37MHRAQ09AA3Bryant, Carrier + 3 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.4 · 5 pairings

  112. 112 38MHRCQ09AA3Bryant, Carrier + 3 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.4 · 5 pairings

  113. 113 D5CERAH09AAKAirquest, Arcoaire + 9 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.4 · 11 pairings

  114. 114 DLCERBH09AAKAirquest, Arcoaire + 10 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.4 · 16 pairings

  115. 115 MASAG09-21HS2GBMidea
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.4 · 2 pairings

  116. 10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 8,300 Btu/h · Cold output 80–83% · HSPF2 11.5 · 3 pairings

  117. 117 MO1ES-H12B-2AMidea
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,600 Btu/h · Cold output 70–74% · HSPF2 10.5 · 6 pairings

  118. 118 MO1BS-H09B-2AMidea
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.4 · 1 pairing

  119. 24,400 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,600 Btu/h · Cold output 74–78% · HSPF2 11.1 · 4 pairings

  120. 25,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 15,500 Btu/h · Cold output 62–64% · HSPF2 9.3 · 2 pairings

  121. 121 37MHRAQ09AA1Bryant, Carrier + 3 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.1 · 5 pairings

  122. 122 38MHRCQ09AA1Bryant, Carrier + 3 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.1 · 5 pairings

  123. 123 D5CERAH09AAJAirquest, Arcoaire + 9 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.1 · 11 pairings

  124. 124 DLCERBH09AAJAirquest, Arcoaire + 10 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.1 · 16 pairings

  125. 125 MASAG09-21HS1GBMidea
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.1 · 2 pairings

  126. 126 MOX230-09HFN1-BS5WAlsetria, Eco Air + 2 more
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 60–86% · HSPF2 9.1 · 6 pairings

  127. 127 MO1BS-H09B-1AMidea
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,000 Btu/h · Cold output 70% · HSPF2 9.0 · 1 pairing

  128. 128 MO1ES-H18B-2AMidea
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 13,000 Btu/h · Cold output 70–77% · HSPF2 11.1 · 8 pairings

  129. 129 38MGHBQ48EA3Bryant, Carrier + 3 more
    49,000 Btu/hheating at 47°F 47,500 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 43,500 Btu/h · Cold output 87–92% · HSPF2 9.4 · 15 pairings

  130. 130 MMCMHAQ48EA3Midea

    Same as 38MGHBQ48EA3

    49,000 Btu/hheating at 47°F 47,500 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 43,500 Btu/h · Cold output 87–92% · HSPF2 9.4 · 3 pairings

  131. 131 37MGHAQ36EA3Bryant, Carrier + 3 more
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 100–106% · HSPF2 10.6 · 15 pairings

  132. 132 D5CMHAH36EAKAirquest, Arcoaire + 10 more

    Same as 37MGHAQ36EA3

    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 100–106% · HSPF2 10.6 · 36 pairings

  133. 133 37MGHAQ55FA3Bryant, Carrier + 3 more
    55,000 Btu/hheating at 47°F 52,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Mini-split · 5°F 47,500 Btu/h · Cold output 85–87% · HSPF2 10.6 · 15 pairings

  134. 134 D5CMHAH55FAKAirquest, Arcoaire + 10 more

    Same as 37MGHAQ55FA3

    55,000 Btu/hheating at 47°F 52,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Mini-split · 5°F 47,500 Btu/h · Cold output 85–87% · HSPF2 10.6 · 36 pairings

  135. 135 37MARAQ24AA3Bryant, Carrier + 3 more
    24,400 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,600 Btu/h · Cold output 72–78% · HSPF2 11.0 · 27 pairings

  136. 136 D5CSRAH24AAKAirquest, Arcoaire + 10 more
    24,400 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,600 Btu/h · Cold output 72–78% · HSPF2 11.0 · 56 pairings

  137. 137 MO5GX-H36B-2AMidea
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 100–106% · HSPF2 10.6 · 3 pairings

  138. 138 MO5HX-H36B-2AMidea

    Same as MO5GX-H36B-2A

    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 37,000 Btu/h · Cold output 100–106% · HSPF2 10.6 · 3 pairings

  139. 139 DLCMHBH30DAKAirquest, Arcoaire + 10 more
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 20,400 Btu/h · Cold output 60–77% · HSPF2 9.4 · 36 pairings

  140. 140 MOX430-18HFN1-MU0WAlsetria, Eco Air + 2 more
    19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,800 Btu/h · Cold output 59–75% · HSPF2 10.5 · 22 pairings

  141. 141 MO1ES-H24B-2AMidea
    24,400 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,600 Btu/h · Cold output 72–78% · HSPF2 11.0 · 5 pairings

  142. 142 MO6HX-H60B-2AMidea
    55,000 Btu/hheating at 47°F 52,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Mini-split · 5°F 47,500 Btu/h · Cold output 85–87% · HSPF2 10.6 · 3 pairings

  143. 12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,400 Btu/h · Cold output 70–74% · HSPF2 10.5 · 3 pairings

  144. 144 MOD33-24HFN1-MT0WAlsetria, Arctic King + 3 more
    26,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 16,700 Btu/h · Cold output 56–80% · HSPF2 9.7 · 22 pairings

  145. 145 DLCMRBH48EAKAirquest, Arcoaire + 10 more
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 33,000 Btu/h · Cold output 69% · HSPF2 9.5 · 12 pairings

  146. 146 DLCMHBH48EAKAirquest, Arcoaire + 10 more
    49,000 Btu/hheating at 47°F 47,500 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Mini-split · 5°F 43,500 Btu/h · Cold output 87–92% · HSPF2 9.4 · 36 pairings

  147. 147 MO4GX-H27B-2AMidea
    27,000 Btu/hheating at 47°F 27,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 27,000 Btu/h · Cold output 96–100% · HSPF2 10.0 · 3 pairings

  148. 148 MO4HX-H27B-2AMidea

    Same as MO4GX-H27B-2A

    27,000 Btu/hheating at 47°F 27,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 27,000 Btu/h · Cold output 96–100% · HSPF2 10.0 · 3 pairings

  149. 149 27VNA324A*030*Carrier
    27,400 Btu/hheating at 47°F 23,200 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 22,200 Btu/h · Cold output 76–82% · HSPF2 9.5 · 430 pairings

  150. 150 293VAN024**AA*Bryant
    27,400 Btu/hheating at 47°F 23,200 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 22,200 Btu/h · Cold output 76–82% · HSPF2 9.5 · 430 pairings

  151. 151 B5H3V24*K*AAA*ACiQ, Airquest + 7 more
    27,400 Btu/hheating at 47°F 23,200 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 22,200 Btu/h · Cold output 76–82% · HSPF2 9.5 · 3,771 pairings

  152. 152 27VNA348A*030*Carrier
    48,500 Btu/hheating at 47°F 45,500 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 36,600 Btu/h · Cold output 74–77% · HSPF2 9.0 · 78 pairings

  153. 153 293VAN048**AA*Bryant
    48,500 Btu/hheating at 47°F 45,500 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 36,600 Btu/h · Cold output 74–77% · HSPF2 9.0 · 78 pairings

  154. 154 B5H3V48*K*AAA*ACiQ, Airquest + 7 more
    48,000 Btu/hheating at 47°F 43,500 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 36,600 Btu/h · Cold output 74–77% · HSPF2 9.0 · 648 pairings

  155. 155 38MHRCQ30AA3Bryant, Carrier + 3 more
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 20,000 Btu/h · Cold output 67% · HSPF2 8.7 · 5 pairings

  156. 156 DLCERBH30AAKAirquest, Arcoaire + 10 more
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 20,000 Btu/h · Cold output 67% · HSPF2 8.7 · 15 pairings

  157. 157 MOD-30HFN1CAMidea
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 18,400 Btu/h · Cold output 61% · HSPF2 8.2 · 1 pairing

  158. 30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 18,400 Btu/h · Cold output 61% · HSPF2 8.2 · 1 pairing

  159. 159 38MGRBQ18BA3Bryant, Carrier + 3 more
    19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,900 Btu/h · Cold output 66–70% · HSPF2 10.2 · 17 pairings

  160. 160 MMCMRAQ18BA3Midea

    Same as 38MGRBQ18BA3

    19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,900 Btu/h · Cold output 66–70% · HSPF2 10.2 · 3 pairings

  161. 161 D5CSRAH18AAKAirquest, Arcoaire + 10 more
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 13,000 Btu/h · Cold output 70–77% · HSPF2 10.8 · 89 pairings

  162. 162 25VNA448A*031*Carrier
    46,500 Btu/hheating at 47°F 43,500 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 36,400 Btu/h · Cold output 78% · HSPF2 9.0 · 6 pairings

  163. 163 284ANV048*0**B*Bryant
    46,500 Btu/hheating at 47°F 43,500 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 36,400 Btu/h · Cold output 78% · HSPF2 9.0 · 6 pairings

  164. 18,000 Btu/hheating at 47°F 16,800 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,800 Btu/h · Cold output 71% · HSPF2 11.3 · 3 pairings

  165. 165 38MGHBQ36DA3Bryant, Carrier + 3 more
    37,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 34,400 Btu/h · Cold output 89–97% · HSPF2 10.2 · 15 pairings

  166. 166 MMCMHAQ36DA3Midea

    Same as 38MGHBQ36DA3

    37,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 34,400 Btu/h · Cold output 89–97% · HSPF2 10.2 · 3 pairings

  167. 167 37MAHAQ24AA3Bryant, Carrier + 3 more
    26,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 24,000 Btu/h · Cold output 83–95% · HSPF2 11.7 · 27 pairings

  168. 168 D5CSHAH24AAKAirquest, Arcoaire + 11 more
    26,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 24,000 Btu/h · Cold output 83–95% · HSPF2 11.7 · 61 pairings

  169. 169 37MARAQ30AA3Bryant, Carrier + 3 more
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 20,000 Btu/h · Cold output 67–68% · HSPF2 9.5 · 12 pairings

  170. 48,500 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 37,000 Btu/h · Cold output 72–77% · HSPF2 9.0 · 138 pairings

  171. 171 C5H3V48*K*AAA*Comfortmaker, Day & Night, Keeprite
    48,500 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 37,000 Btu/h · Cold output 72–77% · HSPF2 9.0 · 414 pairings

  172. 172 H5H3V48*K*AAA*ACiQ, Airquest + 2 more
    48,500 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 37,000 Btu/h · Cold output 72–77% · HSPF2 9.0 · 539 pairings

  173. 173 T5H3V48*K*AAA*Tempstar
    48,500 Btu/hheating at 47°F 45,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Central · 5°F 37,000 Btu/h · Cold output 72–77% · HSPF2 9.0 · 138 pairings

  174. 174 MO1BS-H30B-2AMidea
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 20,000 Btu/h · Cold output 67–68% · HSPF2 9.0 · 3 pairings

  175. 175 MOD30-30HFN1-MS0WMDV, Midea
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 17,500 Btu/h · Cold output 58–61% · HSPF2 8.7 · 4 pairings

  176. 176 27VNA336A*030*Carrier
    38,500 Btu/hheating at 47°F 34,400 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 28,000 Btu/h · Cold output 71–77% · HSPF2 8.5 · 564 pairings

  177. 177 293VAN036**AA*Bryant
    38,500 Btu/hheating at 47°F 34,400 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 28,000 Btu/h · Cold output 71–77% · HSPF2 8.5 · 564 pairings

  178. 37,400 Btu/hheating at 47°F 35,200 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 28,000 Btu/h · Cold output 71–77% · HSPF2 8.5 · 564 pairings

  179. 179 B5H3V36*K*AAA*ACiQ, Airquest + 7 more
    38,500 Btu/hheating at 47°F 34,400 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 28,000 Btu/h · Cold output 71–77% · HSPF2 8.5 · 4,626 pairings

  180. 180 C5H3V36*K*AAA*Comfortmaker, Day & Night, Keeprite
    37,400 Btu/hheating at 47°F 35,200 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 28,000 Btu/h · Cold output 71–77% · HSPF2 8.5 · 1,692 pairings

  181. 181 H5H3V36*K*AAA*ACiQ, Airquest + 2 more
    37,400 Btu/hheating at 47°F 35,200 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 28,000 Btu/h · Cold output 71–77% · HSPF2 8.5 · 2,256 pairings

  182. 182 T5H3V36*K*AAA*Tempstar
    37,400 Btu/hheating at 47°F 35,200 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 28,000 Btu/h · Cold output 71–77% · HSPF2 8.5 · 564 pairings

  183. 183 MO1HS-H24B-2AMidea
    26,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 24,000 Btu/h · Cold output 83–95% · HSPF2 11.7 · 5 pairings

  184. 184 37MHRAQ18AA3Bryant, Carrier + 3 more
    18,800 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 11,500 Btu/h · Cold output 61% · HSPF2 9.1 · 5 pairings

  185. 185 D5CERAH18AAKAirquest, Arcoaire + 9 more
    18,800 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 11,500 Btu/h · Cold output 61% · HSPF2 9.1 · 11 pairings

  186. 186 37MAHAQ18AA3Bryant, Carrier + 3 more
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 88–103% · HSPF2 11.0 · 42 pairings

  187. 187 MO1BS-H18B-2AMidea
    18,800 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 11,500 Btu/h · Cold output 61% · HSPF2 9.1 · 1 pairing

  188. 188 DLCSRBH30AAK11Airquest, Arcoaire + 12 more
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 19,000 Btu/h · Cold output 62–67% · HSPF2 8.7 · 45 pairings

  189. 189 DLCSRBH30AAKAirquest, Arcoaire + 12 more
    30,000 Btu/hheating at 47°F 30,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 18,600 Btu/h · Cold output 61–63% · HSPF2 8.7 · 46 pairings

  190. 190 D5CSHAH18AAKAirquest, Arcoaire + 11 more
    19,500 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 88–103% · HSPF2 10.8 · 97 pairings

  191. 191 MO1HS-H18B-2AMidea
    17,000 Btu/hheating at 47°F 16,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 17,500 Btu/h · Cold output 88–103% · HSPF2 10.8 · 8 pairings

  192. 192 37MBRAQ36AA3Bryant, Carrier + 3 more
    38,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 26,600 Btu/h · Cold output 70% · HSPF2 10.4 · 5 pairings

  193. 193 D5CLRAH36AAKAirquest, Arcoaire + 9 more
    38,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 26,600 Btu/h · Cold output 70% · HSPF2 10.4 · 11 pairings

  194. 194 MO1BU-H36B-2AMidea
    38,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 26,600 Btu/h · Cold output 70% · HSPF2 10.3 · 1 pairing

  195. 38,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 26,600 Btu/h · Cold output 70% · HSPF2 10.3 · 1 pairing

  196. 196 DLCMRBH18BAKAirquest, Arcoaire + 10 more
    19,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,900 Btu/h · Cold output 66–70% · HSPF2 10.0 · 42 pairings

  197. 197 DLCMRBH36DAKAirquest, Arcoaire + 10 more
    37,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 24,000 Btu/h · Cold output 65% · HSPF2 9.2 · 12 pairings

  198. 198 XH960E2C11Champion, Coleman + 4 more
    48,000 Btu/hheating at 47°F 47,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 45,000 Btu/h · Cold output 76–95% · HSPF2 8.5 · 858 pairings

  199. 199 38MTRAQ27CA3Bryant, Carrier + 3 more
    27,000 Btu/hheating at 47°F 27,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 16,400 Btu/h · Cold output 61% · HSPF2 8.5 · 5 pairings

  200. 200 DLCMTAH27CAKAirquest, Arcoaire + 10 more

    Same as 38MTRAQ27CA3

    27,000 Btu/hheating at 47°F 27,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 16,400 Btu/h · Cold output 61% · HSPF2 8.5 · 12 pairings

Airquest, Arcoaire +14 more: shared model numbers, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2)
# Model Brands Type Size At 5°FBtu/h · heating At 47°FBtu/h · heating At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed SEER2median pairing HSPF2Btu/Wh · median pairing Compressor Refrigerant Market Pairings
1 37MPRAQ06AA3 Bryant, Carrier + 3 more Mini-split 6,000 Btu13,500 9,000 6,000 150% 2.00 35.1 15.6 Variable R-454B US CA 7
2 MO1SS-H06B-2A Midea Mini-split 6,000 Btu13,500 9,000 6,000 150% 2.00 35.0 15.6 Variable R-454B US CA 1
3 37MPRAQ09AA3 Bryant, Carrier + 3 more Mini-split 9,000 Btu13,500 12,000 9,000 113% 2.00 33.5 14.6 Variable R-454B US CA 7
4 MO1SS-H09B-2A Midea Mini-split 9,000 Btu13,500 12,000 9,000 113% 2.00 33.3 14.6 Variable R-454B US CA 1
5 D5CPRAH06AAK Airquest, Arcoaire + 9 more Mini-split 6,000 Btu13,500 9,000 6,000 150% 2.00 33.1 15.6 Variable R-454B US CA 11
6 D5CPRAH09AAK Airquest, Arcoaire + 9 more Mini-split 9,000 Btu13,500 12,000 9,000 113% 2.00 31.5 14.6 Variable R-454B US CA 11
7 37MPRAQ12AA3 Bryant, Carrier + 3 more Mini-split 12,000 Btu (1-ton)13,500 12,000 12,000 113% 2.00 29.5 12.7 Variable R-454B US CA 7
8 MO1SS-H12B-2A Midea Mini-split 12,000 Btu (1-ton)13,500 12,000 12,000 113% 2.00 29.4 12.7 Variable R-454B US CA 1
9 MOX430-09HFN1-MZG5W MDV, Midea Mini-split 9,000 Btu13,700 12,000 9,000 100–114% 1.85 28.5 12.0 Variable R-410A US CA 5
10 D5CPRAH12AAK Airquest, Arcoaire + 9 more Mini-split 12,000 Btu (1-ton)13,500 12,000 12,000 113% 2.00 28.0 12.7 Variable R-454B US CA 11
11 DLCPRBH09AAK Airquest, Arcoaire + 10 more Mini-split 9,000 Btu13,700 12,000 9,000 100–114% 1.85 27.0 15.0 Variable R-410A US CA 29
12 38MPRBQ09AA3 Bryant, Carrier + 3 more Mini-split 9,000 Btu13,700 12,000 9,000 100–114% 1.85 27.0 12.0 Variable R-410A US CA 12
13 38MPRBQ12AA3 Bryant, Carrier + 3 more Mini-split 12,000 Btu (1-ton)13,700 12,000 12,000 100–114% 1.85 27.0 12.0 Variable R-410A US CA 12
14 MOX430-12HFN1-MZ60W MDV, Midea Mini-split 12,000 Btu (1-ton)13,700 12,000 12,000 100–114% 1.85 27.0 12.0 Variable R-410A US CA 5
15 38MPRBQ18AA3 Bryant, Carrier + 3 more Mini-split 18,000 Btu (1.5-ton)24,000 20,000 18,000 120% 2.89 26.3 11.0 Variable R-410A US CA 5
16 DLCPRBH18AAK Airquest, Arcoaire + 10 more Mini-split 18,000 Btu (1.5-ton)24,000 20,000 18,000 120% 2.89 26.3 11.0 Variable R-410A US CA 16
17 37MPRAQ18AA3 Bryant, Carrier + 3 more Mini-split 18,000 Btu (1.5-ton)22,600 20,000 18,000 113% 2.34 25.8 16.2 Variable R-454B US CA 7
18 MO1SS-H18B-2A Midea Mini-split 18,000 Btu (1.5-ton)22,600 20,000 18,000 113% 2.34 25.6 16.2 Variable R-454B US CA 1
19 MOX3-12HFN10AE Midea Mini-split 12,000 Btu (1-ton)8,400 12,000 12,000 70% 2.30 25.5 10.6 Variable R-454B US CA 1
20 MO1ES-H09B-1A Midea Mini-split 9,000 Btu7,200 10,000 9,000 72% 2.23 25.4 10.0 Variable R-454B US CA 2
21 DLCPRBH12AAK Airquest, Arcoaire + 10 more Mini-split 12,000 Btu (1-ton)13,700 12,000 12,000 100–114% 1.85 25.3 11.7 Variable R-410A US CA 30
22 MO4EX-H27B-2B Midea Mini-split 24,000 Btu (2-ton)19,000 27,000 27,000 70% 2.00 25.0 9.5 Variable R-454B US CA 1
23 M4OD30-24HFN10-M1D Arctic King, MDV, Midea Mini-split 24,000 Btu (2-ton)18,000 25,000 24,000 72% 2.00 25.0 9.5 Variable R-454B US CA 5
24 D5CPRAH18AA Airquest, Arcoaire + 9 more Mini-split 18,000 Btu (1.5-ton)22,600 20,000 18,000 113% 2.34 24.5 15.2 Variable R-454B US CA 11
25 MOX230-09HFN1-BW0W MDV, Midea Mini-split 9,000 Btu6,700 10,000 9,000 65–68% 2.11 24.5 9.9 Variable R-410A US CA 4
26 38MARBQ06AA3 Bryant, Carrier + 3 more Mini-split 6,000 Btu7,500 7,000 6,000 107–113% 2.05 24.3 12.2 Variable R-410A US CA 10
27 37MAHAQ09AA3 Bryant, Carrier + 3 more Mini-split 9,000 Btu11,300 9,000 9,000 96–126% 1.84 24.0 12.5 Variable R-454B US CA 32
28 DLCSRBH09AAK Airquest, Arcoaire + 12 more Mini-split 9,000 Btu10,600 12,000 9,000 88–110% 1.85 24.0 11.6 Variable R-410A US CA 99
29 MOX430-18HFN1-MT8W MDV, Midea Mini-split 18,000 Btu (1.5-ton)12,800 18,000 18,000 71% 2.44 24.0 10.5 Variable R-410A US CA 2
30 38MARBQ12AA3 Bryant, Carrier + 3 more Mini-split 12,000 Btu (1-ton)11,900 12,000 12,000 83–100% 1.85 23.6 10.0 Variable R-410A US CA 41
31 DLCSRBH06AAK Airquest, Arcoaire + 12 more Mini-split 6,000 Btu7,500 7,000 6,000 101–113% 2.00 23.5 12.0 Variable R-410A US CA 48
32 MOX4-18HFN10AE Midea Mini-split 18,000 Btu (1.5-ton)12,800 18,000 18,000 71% 2.10 23.5 10.8 Variable R-454B US CA 1
33 MOX4-18HFN1AA Midea Mini-split 18,000 Btu (1.5-ton)11,300 19,000 18,000 59% 2.02 23.5 10.8 Variable R-410A US CA 1
34 38MARBQ12AA1 Bryant, Carrier + 3 more Mini-split 12,000 Btu (1-ton)6,800 12,000 12,000 57% 2.16 23.5 10.0 Variable R-410A US CA 5
35 DLCSRBH12AAJ Airquest, Arcoaire + 12 more Mini-split 12,000 Btu (1-ton)6,800 12,000 12,000 56–57% 2.16 23.5 10.0 Variable R-410A US CA 35
36 MO1ES-H15B-2A Midea Mini-split 15,000 Btu11,500 15,000 15,000 77% 1.80 23.5 9.9 Variable R-454B US CA 1
37 37MARAQ12AA1 Bryant, Carrier + 3 more Mini-split 12,000 Btu (1-ton)7,700 12,000 12,000 64% 2.33 23.5 9.5 Variable R-454B US CA 7
38 D5CSRAH12AAJ Airquest, Arcoaire + 10 more Mini-split 12,000 Btu (1-ton)7,700 12,000 12,000 64% 2.33 23.5 9.5 Variable R-454B US CA 12
39 MO1ES-H12B-1A Midea Mini-split 12,000 Btu (1-ton)7,700 12,000 12,000 64% 2.33 23.4 9.5 Variable R-454B US CA 2
40 D5CSHAH09AAK Airquest, Arcoaire + 10 more Mini-split 9,000 Btu11,200 10,000 9,000 96–126% 1.84 23.4 12.4 Variable R-454B US CA 72
41 MO1HS-H09B-2A Midea Mini-split 9,000 Btu11,200 10,000 9,000 96–126% 1.84 23.3 12.3 Variable R-454B US CA 6
42 DLCSRBH12AAK Airquest, Arcoaire + 12 more Mini-split 12,000 Btu (1-ton)12,000 12,000 12,000 88–100% 1.88 23.1 10.2 Variable R-410A US CA 110
43 MOD-24HFN10AE Midea Mini-split 24,000 Btu (2-ton)19,600 25,000 24,000 78% 2.54 23.0 11.7 Variable R-454B US CA 1
44 37MAHAQ12AA3 Bryant, Carrier + 3 more Mini-split 12,000 Btu (1-ton)11,500 12,000 12,000 92–100% 1.90 23.0 10.5 Variable R-454B US CA 32
45 MOX330-12HFN1-MW5W Alsetria, Eco Air + 2 more Mini-split 12,000 Btu (1-ton)11,900 12,000 12,000 83–100% 1.87 23.0 10.1 Variable R-410A US CA 20
46 MOX230-09HFN1-BW0W-9K Midea Mini-split 9,000 Btu6,700 10,000 9,000 67% 2.06 23.0 9.8 Variable R-410A US CA 1
47 37MGRAQ30EA3 Bryant, Carrier + 3 more Mini-split 30,000 Btu (2.5-ton)25,400 31,000 30,000 81–84% 2.00 23.0 9.8 Variable R-454B US CA 15
48 D5CMRAH30EAKSame as 37MGRAQ30EA3 Airquest, Arcoaire + 9 more Mini-split 30,000 Btu (2.5-ton)25,400 31,000 30,000 81–84% 2.00 23.0 9.8 Variable R-454B US CA 33
49 38MGHBQ30DA3 Bryant, Carrier + 3 more Mini-split 30,000 Btu (2.5-ton)24,600 30,000 30,000 80–84% 1.74 23.0 9.5 Variable R-410A US CA 15
50 MMCMHAQ30DA3Same as 38MGHBQ30DA3 Midea Mini-split 30,000 Btu (2.5-ton)24,600 30,000 30,000 80–84% 1.74 23.0 9.5 Variable R-410A US CA 3
51 37MGRAQ24DA3 Bryant, Carrier + 3 more Mini-split 24,000 Btu (2-ton)18,000 25,000 24,000 72% 2.00 23.0 9.5 Variable R-454B US CA 15
52 D5CMRAH24DAKSame as 37MGRAQ24DA3 Airquest, Arcoaire + 9 more Mini-split 24,000 Btu (2-ton)18,000 25,000 24,000 72% 2.00 23.0 9.5 Variable R-454B US CA 33
53 M4OD30-27HFN10-M1P Midea Mini-split 24,000 Btu (2-ton)18,900 26,800 26,800 70–71% 2.00 23.0 9.3 Variable R-454B US CA 3
54 MO4DX-H27B-2A Midea Mini-split 24,000 Btu (2-ton)18,900 26,800 26,800 70–71% 2.00 23.0 9.3 Variable R-454B US CA 3
55 MO4EX-H27B-2A Midea Mini-split 24,000 Btu (2-ton)18,900 26,800 26,800 70–71% 2.00 23.0 9.3 Variable R-454B US CA 3
56 38MGHBQ24CA3 Bryant, Carrier + 3 more Mini-split 24,000 Btu (2-ton)18,200 24,400 24,000 74–75% 1.90 23.0 9.9 Variable R-410A US CA 18
57 MMCMHAQ24CA3Same as 38MGHBQ24CA3 Midea Mini-split 24,000 Btu (2-ton)18,200 24,400 24,000 74–75% 1.90 23.0 9.9 Variable R-410A US CA 3
58 MOX230-12HFN1-MV5W Alsetria, Eco Air + 2 more Mini-split 12,000 Btu (1-ton)8,100 12,000 12,000 62–70% 2.27 22.9 10.3 Variable R-410A US CA 20
59 MOX230-12HFN1-BW0W MDV, Midea Mini-split 12,000 Btu (1-ton)6,700 12,000 12,000 47–57% 2.06 22.7 10.0 Variable R-410A US CA 5
60 38MGRBQ48EA3 Bryant, Carrier + 3 more Mini-split 48,000 Btu (4-ton)33,000 48,000 48,000 67–69% 1.78 22.7 9.0 Variable R-410A US CA 10
61 MMCMRAQ48EA3Same as 38MGRBQ48EA3 Midea Mini-split 48,000 Btu (4-ton)33,000 48,000 48,000 67–69% 1.78 22.7 9.0 Variable R-410A US CA 2
62 D5CSHAH12AAK Airquest, Arcoaire + 10 more Mini-split 12,000 Btu (1-ton)11,500 12,000 12,000 92–100% 1.92 22.7 10.6 Variable R-454B US CA 72
63 MO1HS-H12B-2A Midea Mini-split 12,000 Btu (1-ton)11,500 12,000 12,000 92–100% 1.92 22.6 10.5 Variable R-454B US CA 6
64 37MGRAQ18CA3 Bryant, Carrier + 3 more Mini-split 18,000 Btu (1.5-ton)14,000 19,000 18,000 71–77% 2.30 22.6 9.9 Variable R-454B US CA 15
65 D5CMRAH18CAKSame as 37MGRAQ18CA3 Airquest, Arcoaire + 9 more Mini-split 18,000 Btu (1.5-ton)14,000 19,000 18,000 71–77% 2.30 22.6 9.9 Variable R-454B US CA 33
66 M3OX430-18HFN10-M1P Midea Mini-split 18,000 Btu (1.5-ton)14,000 19,000 18,000 71–77% 2.30 22.6 9.9 Variable R-454B US CA 3
67 MO3EX-H18B-2A Midea Mini-split 18,000 Btu (1.5-ton)14,000 19,000 18,000 71–77% 2.30 22.6 9.9 Variable R-454B US CA 3
68 MOX230-09HFN1-MW5W Alsetria, Eco Air + 2 more Mini-split 9,000 Btu7,500 10,000 9,000 70–113% 2.10 22.5 11.4 Variable R-410A US CA 23
69 37MGRAQ48FA3 Bryant, Carrier + 3 more Mini-split 48,000 Btu (4-ton)37,000 47,500 46,000 75–81% 2.05 22.5 10.5 Variable R-454B US CA 15
70 D5CMRAH48FAKSame as 37MGRAQ48FA3 Airquest, Arcoaire + 9 more Mini-split 48,000 Btu (4-ton)37,000 47,500 46,000 75–81% 2.05 22.5 10.5 Variable R-454B US CA 33
71 37MGHAQ18CA3 Bryant, Carrier + 3 more Mini-split 18,000 Btu (1.5-ton)18,500 20,000 19,000 90–95% 2.00 22.5 10.3 Variable R-454B US CA 15
72 D5CMHAH18CAKSame as 37MGHAQ18CA3 Airquest, Arcoaire + 10 more Mini-split 18,000 Btu (1.5-ton)18,500 20,000 19,000 90–95% 2.00 22.5 10.3 Variable R-454B US CA 36
73 MO3GX-H18B-2A Midea Mini-split 18,000 Btu (1.5-ton)18,500 20,000 19,000 90–95% 2.00 22.5 10.2 Variable R-454B US CA 3
74 MO3HX-H18B-2ASame as MO3GX-H18B-2A Midea Mini-split 18,000 Btu (1.5-ton)18,500 20,000 19,000 90–95% 2.00 22.5 10.2 Variable R-454B US CA 3
75 37MHRAQ30AA3 Bryant, Carrier + 3 more Mini-split 30,000 Btu (2.5-ton)20,000 30,000 30,000 67% 1.94 22.4 9.0 Variable R-454B US CA 5
76 D5CERAH30AAK Airquest, Arcoaire + 9 more Mini-split 30,000 Btu (2.5-ton)20,000 30,000 30,000 67% 1.94 22.4 9.0 Variable R-454B US CA 11
77 37MARAQ18AA3 Bryant, Carrier + 3 more Mini-split 18,000 Btu (1.5-ton)13,000 18,000 18,000 70–77% 2.20 22.3 10.8 Variable R-454B US CA 42
78 38MARBQ09AA3 Bryant, Carrier + 3 more Mini-split 9,000 Btu10,500 10,900 9,000 85–110% 1.85 22.3 11.3 Variable R-410A US CA 30
79 M3OJ-27HFN1-M Alsetria, Eco Air + 2 more Mini-split 30,000 Btu (2.5-ton)18,800 28,000 28,000 61–68% 2.00 22.3 9.2 Variable R-410A US CA 18
80 M3OJ-27HFN1-M-CO Midea Mini-split 30,000 Btu (2.5-ton)18,800 28,000 27,400 67–68% 2.00 22.3 9.2 Variable R-410A US CA 3
81 37MARAQ09AA3 Bryant, Carrier + 3 more Mini-split 9,000 Btu8,300 10,000 9,000 73–96% 2.27 22.2 11.8 Variable R-454B US CA 32
82 MO1HS-H15B-2A Midea Mini-split 15,000 Btu17,500 15,400 15,400 114% 1.83 22.2 11.5 Variable R-454B US CA 1
83 37MARAQ12AA3 Bryant, Carrier + 3 more Mini-split 12,000 Btu (1-ton)8,600 12,000 12,000 70–74% 2.40 22.2 10.5 Variable R-454B US CA 32
84 M6OE30-48HFN10-M1P Midea Mini-split 48,000 Btu (4-ton)37,000 47,500 46,000 75–81% 2.05 22.2 10.5 Variable R-454B US CA 3
85 MO6EX-H48B-2A Midea Mini-split 48,000 Btu (4-ton)37,000 47,500 46,000 75–81% 2.05 22.2 10.5 Variable R-454B US CA 3
86 37MAHAQ06AA3 Bryant, Carrier + 3 more Mini-split 6,000 Btu7,800 8,000 6,500 98–110% 2.40 22.0 13.8 Variable R-454B US CA 17
87 D5CSHAH06AAK Airquest, Arcoaire + 10 more Mini-split 6,000 Btu7,800 8,000 6,500 98–110% 2.40 22.0 13.8 Variable R-454B US CA 35
88 MO1HS-H06B-2A Midea Mini-split 6,000 Btu7,800 8,000 6,500 98–110% 2.40 22.0 13.8 Variable R-454B US CA 3
89 MOD-24HFN1AA Midea Mini-split 24,000 Btu (2-ton)15,500 25,000 24,000 62% 1.80 22.0 10.0 Variable R-410A US CA 1
90 37MGHAQ24DA3 Bryant, Carrier + 3 more Mini-split 24,000 Btu (2-ton)25,000 25,000 24,000 100% 1.95 22.0 9.8 Variable R-454B US CA 15
91 D5CMHAH24DAKSame as 37MGHAQ24DA3 Airquest, Arcoaire + 10 more Mini-split 24,000 Btu (2-ton)25,000 25,000 24,000 100% 1.95 22.0 9.8 Variable R-454B US CA 36
92 37MGRAQ36EA3 Bryant, Carrier + 3 more Mini-split 36,000 Btu (3-ton)26,000 37,000 35,000 70% 2.00 22.0 9.4 Variable R-454B US CA 15
93 D5CMRAH36EAKSame as 37MGRAQ36EA3 Airquest, Arcoaire + 9 more Mini-split 36,000 Btu (3-ton)26,000 37,000 35,000 70% 2.00 22.0 9.4 Variable R-454B US CA 33
94 M5OD30-36HFN10-M1PSame as 37MGRAQ36EA3 Midea Mini-split 36,000 Btu (3-ton)26,000 37,000 35,000 70% 2.00 22.0 9.4 Variable R-454B US CA 3
95 MO5DX-H36B-2ASame as 37MGRAQ36EA3 Midea Mini-split 36,000 Btu (3-ton)26,000 37,000 35,000 70% 2.00 22.0 9.4 Variable R-454B US CA 3
96 MO5EX-H36B-2ASame as 37MGRAQ36EA3 Midea Mini-split 36,000 Btu (3-ton)26,000 37,000 35,000 70% 2.00 22.0 9.4 Variable R-454B US CA 3
97 D5CSRAH09AAK Airquest, Arcoaire + 9 more Mini-split 9,000 Btu8,300 10,000 9,000 73–96% 2.26 22.0 11.7 Variable R-454B US CA 66
98 38MGRBQ36DA3 Bryant, Carrier + 3 more Mini-split 36,000 Btu (3-ton)24,600 37,000 36,000 65–68% 1.74 22.0 9.4 Variable R-410A US CA 15
99 M4OG-36HFN1-MSame as 38MGRBQ36DA3 Alsetria, Eco Air + 2 more Mini-split 36,000 Btu (3-ton)24,600 37,000 36,000 65–68% 1.74 22.0 9.4 Variable R-410A US CA 14
100 MMCMRAQ36DA3Same as 38MGRBQ36DA3 Midea Mini-split 36,000 Btu (3-ton)24,600 37,000 36,000 65–68% 1.74 22.0 9.4 Variable R-410A US CA 3
101 M5OG-48HFN1-M Alsetria, Eco Air + 2 more Mini-split 48,000 Btu (4-ton)33,000 48,000 48,000 67–71% 1.80 22.0 9.0 Variable R-410A US CA 10
102 MO1ES-H09B-2A Midea Mini-split 9,000 Btu8,300 10,000 9,000 73–96% 2.26 21.9 11.7 Variable R-454B US CA 6
103 M3OJ-24HFN1-M MDV, Midea Mini-split 24,000 Btu (2-ton)18,000 24,000 24,000 71–75% 1.90 21.8 9.7 Variable R-410A US CA 9
104 DLCMHBH24CAK Airquest, Arcoaire + 10 more Mini-split 24,000 Btu (2-ton)17,500 24,000 24,000 71–75% 1.87 21.8 9.7 Variable R-410A US CA 38
105 37MGHAQ48FA3 Bryant, Carrier + 3 more Mini-split 48,000 Btu (4-ton)47,500 48,500 47,000 96–100% 2.00 21.8 11.2 Variable R-454B US CA 15
106 D5CMHAH48FAKSame as 37MGHAQ48FA3 Airquest, Arcoaire + 10 more Mini-split 48,000 Btu (4-ton)47,500 48,500 47,000 96–100% 2.00 21.8 11.2 Variable R-454B US CA 36
107 37MGHAQ30EA3 Bryant, Carrier + 3 more Mini-split 30,000 Btu (2.5-ton)36,000 31,000 30,000 116% 1.98 21.8 10.6 Variable R-454B US CA 15
108 D5CMHAH30EAKSame as 37MGHAQ30EA3 Airquest, Arcoaire + 10 more Mini-split 30,000 Btu (2.5-ton)36,000 31,000 30,000 116% 1.98 21.8 10.6 Variable R-454B US CA 36
109 MO6HX-H48B-2A Midea Mini-split 48,000 Btu (4-ton)47,500 48,500 47,000 96–100% 2.00 21.7 11.0 Variable R-454B US CA 3
110 D5CSRAH12AAK Airquest, Arcoaire + 9 more Mini-split 12,000 Btu (1-ton)8,600 12,000 12,000 70–74% 2.42 21.7 10.5 Variable R-454B US CA 66
111 37MHRAQ09AA3 Bryant, Carrier + 3 more Mini-split 9,000 Btu7,000 10,000 9,000 70% 2.00 21.7 9.4 Variable R-454B US CA 5
112 38MHRCQ09AA3 Bryant, Carrier + 3 more Mini-split 9,000 Btu7,000 10,000 9,000 70% 2.00 21.7 9.4 Variable R-410A US CA 5
113 D5CERAH09AAK Airquest, Arcoaire + 9 more Mini-split 9,000 Btu7,000 10,000 9,000 70% 2.00 21.7 9.4 Variable R-454B US CA 11
114 DLCERBH09AAK Airquest, Arcoaire + 10 more Mini-split 9,000 Btu7,000 10,000 9,000 70% 2.00 21.7 9.4 Variable R-410A US CA 16
115 MASAG09-21HS2GB Midea Mini-split 9,000 Btu7,000 10,000 9,000 70% 2.00 21.7 9.4 Variable R-410A US CA 2
116 MOX230-09HFN10-M1P Midea Mini-split 9,000 Btu8,300 10,000 9,000 80–83% 2.31 21.6 11.5 Variable R-454B US CA 3
117 MO1ES-H12B-2A Midea Mini-split 12,000 Btu (1-ton)8,600 12,000 12,000 70–74% 2.42 21.6 10.5 Variable R-454B US CA 6
118 MO1BS-H09B-2A Midea Mini-split 9,000 Btu7,000 10,000 9,000 70% 2.00 21.6 9.4 Variable R-454B US CA 1
119 MOD30-24HFN10-M1P Midea Mini-split 24,000 Btu (2-ton)18,600 24,400 24,000 74–78% 2.30 21.6 11.1 Variable R-454B US CA 4
120 MOD32-24HFN1-MT0W Midea Mini-split 24,000 Btu (2-ton)15,500 25,000 24,000 62–64% 1.85 21.5 9.3 Variable R-410A US CA 2
121 37MHRAQ09AA1 Bryant, Carrier + 3 more Mini-split 9,000 Btu7,000 10,000 9,000 70% 1.95 21.5 9.1 Variable R-454B US CA 5
122 38MHRCQ09AA1 Bryant, Carrier + 3 more Mini-split 9,000 Btu7,000 10,000 9,000 70% 2.16 21.5 9.1 Variable R-410A US CA 5
123 D5CERAH09AAJ Airquest, Arcoaire + 9 more Mini-split 9,000 Btu7,000 10,000 9,000 70% 1.95 21.5 9.1 Variable R-454B US CA 11
124 DLCERBH09AAJ Airquest, Arcoaire + 10 more Mini-split 9,000 Btu7,000 10,000 9,000 70% 2.16 21.5 9.1 Variable R-410A US CA 16
125 MASAG09-21HS1GB Midea Mini-split 9,000 Btu7,000 10,000 9,000 70% 2.16 21.5 9.1 Variable R-410A US CA 2
126 MOX230-09HFN1-BS5W Alsetria, Eco Air + 2 more Mini-split 9,000 Btu7,000 10,000 9,000 60–86% 2.16 21.5 9.1 Variable R-410A US CA 6
127 MO1BS-H09B-1A Midea Mini-split 9,000 Btu7,000 10,000 9,000 70% 1.95 21.5 9.0 Variable R-454B US CA 1
128 MO1ES-H18B-2A Midea Mini-split 18,000 Btu (1.5-ton)13,000 18,000 18,000 70–77% 2.20 21.5 11.1 Variable R-454B US CA 8
129 38MGHBQ48EA3 Bryant, Carrier + 3 more Mini-split 48,000 Btu (4-ton)43,500 49,000 47,500 87–92% 2.00 21.4 9.4 Variable R-410A US CA 15
130 MMCMHAQ48EA3Same as 38MGHBQ48EA3 Midea Mini-split 48,000 Btu (4-ton)43,500 49,000 47,500 87–92% 2.00 21.4 9.4 Variable R-410A US CA 3
131 37MGHAQ36EA3 Bryant, Carrier + 3 more Mini-split 36,000 Btu (3-ton)37,000 36,000 36,000 100–106% 2.00 21.3 10.6 Variable R-454B US CA 15
132 D5CMHAH36EAKSame as 37MGHAQ36EA3 Airquest, Arcoaire + 10 more Mini-split 36,000 Btu (3-ton)37,000 36,000 36,000 100–106% 2.00 21.3 10.6 Variable R-454B US CA 36
133 37MGHAQ55FA3 Bryant, Carrier + 3 more Mini-split 54,000 Btu (4.5-ton)47,500 55,000 52,000 85–87% 2.05 21.3 10.6 Variable R-454B US CA 15
134 D5CMHAH55FAKSame as 37MGHAQ55FA3 Airquest, Arcoaire + 10 more Mini-split 54,000 Btu (4.5-ton)47,500 55,000 52,000 85–87% 2.05 21.3 10.6 Variable R-454B US CA 36
135 37MARAQ24AA3 Bryant, Carrier + 3 more Mini-split 24,000 Btu (2-ton)18,600 24,400 24,000 72–78% 2.30 21.2 11.0 Variable R-454B US CA 27
136 D5CSRAH24AAK Airquest, Arcoaire + 10 more Mini-split 24,000 Btu (2-ton)18,600 24,400 24,000 72–78% 2.30 21.2 11.0 Variable R-454B US CA 56
137 MO5GX-H36B-2A Midea Mini-split 36,000 Btu (3-ton)37,000 36,000 36,000 100–106% 2.00 21.2 10.6 Variable R-454B US CA 3
138 MO5HX-H36B-2ASame as MO5GX-H36B-2A Midea Mini-split 36,000 Btu (3-ton)37,000 36,000 36,000 100–106% 2.00 21.2 10.6 Variable R-454B US CA 3
139 DLCMHBH30DAK Airquest, Arcoaire + 10 more Mini-split 30,000 Btu (2.5-ton)20,400 30,000 30,000 60–77% 1.78 21.2 9.4 Variable R-410A US CA 36
140 MOX430-18HFN1-MU0W Alsetria, Eco Air + 2 more Mini-split 18,000 Btu (1.5-ton)12,800 19,000 18,000 59–75% 2.31 21.2 10.5 Variable R-410A US CA 22
141 MO1ES-H24B-2A Midea Mini-split 24,000 Btu (2-ton)18,600 24,400 24,000 72–78% 2.30 21.1 11.0 Variable R-454B US CA 5
142 MO6HX-H60B-2A Midea Mini-split 54,000 Btu (4.5-ton)47,500 55,000 52,000 85–87% 2.05 21.1 10.6 Variable R-454B US CA 3
143 MOX230-12HFN10-M1P Midea Mini-split 12,000 Btu (1-ton)8,400 12,000 12,000 70–74% 2.40 21.1 10.5 Variable R-454B US CA 3
144 MOD33-24HFN1-MT0W Alsetria, Arctic King + 3 more Mini-split 24,000 Btu (2-ton)16,700 26,000 24,000 56–80% 1.91 21.1 9.7 Variable R-410A US CA 22
145 DLCMRBH48EAK Airquest, Arcoaire + 10 more Mini-split 48,000 Btu (4-ton)33,000 48,000 48,000 69% 1.80 21.1 9.5 Variable R-410A US CA 12
146 DLCMHBH48EAK Airquest, Arcoaire + 10 more Mini-split 48,000 Btu (4-ton)43,500 49,000 47,500 87–92% 2.00 21.1 9.4 Variable R-410A US CA 36
147 MO4GX-H27B-2A Midea Mini-split 30,000 Btu (2.5-ton)27,000 27,000 27,000 96–100% 2.00 21.0 10.0 Variable R-454B US CA 3
148 MO4HX-H27B-2ASame as MO4GX-H27B-2A Midea Mini-split 30,000 Btu (2.5-ton)27,000 27,000 27,000 96–100% 2.00 21.0 10.0 Variable R-454B US CA 3
149 27VNA324A*030* Carrier Central 24,000 Btu (2-ton)22,200 27,400 23,200 76–82% 1.98 21.0 9.5 Variable R-454B US CA 430
150 293VAN024**AA* Bryant Central 24,000 Btu (2-ton)22,200 27,400 23,200 76–82% 1.98 21.0 9.5 Variable R-454B US CA 430
151 B5H3V24*K*AAA* ACiQ, Airquest + 7 more Central 24,000 Btu (2-ton)22,200 27,400 23,200 76–82% 1.98 21.0 9.5 Variable R-454B US CA 3,771
152 27VNA348A*030* Carrier Central 42,000 Btu (3.5-ton)36,600 48,500 45,500 74–77% 1.88 21.0 9.0 Variable R-454B US CA 78
153 293VAN048**AA* Bryant Central 42,000 Btu (3.5-ton)36,600 48,500 45,500 74–77% 1.88 21.0 9.0 Variable R-454B US CA 78
154 B5H3V48*K*AAA* ACiQ, Airquest + 7 more Central 42,000 Btu (3.5-ton)36,600 48,000 43,500 74–77% 1.88 21.0 9.0 Variable R-454B US CA 648
155 38MHRCQ30AA3 Bryant, Carrier + 3 more Mini-split 30,000 Btu (2.5-ton)20,000 30,000 30,000 67% 1.85 21.0 8.7 Variable R-410A US CA 5
156 DLCERBH30AAK Airquest, Arcoaire + 10 more Mini-split 30,000 Btu (2.5-ton)20,000 30,000 30,000 67% 1.85 21.0 8.7 Variable R-410A US CA 15
157 MOD-30HFN1CA Midea Mini-split 30,000 Btu (2.5-ton)18,400 30,000 30,000 61% 1.86 21.0 8.2 Variable R-410A US CA 1
158 MOD30-30HFN1-MS0WXT Midea Mini-split 30,000 Btu (2.5-ton)18,400 30,000 30,000 61% 1.86 21.0 8.2 Variable R-410A US CA 1
159 38MGRBQ18BA3 Bryant, Carrier + 3 more Mini-split 18,000 Btu (1.5-ton)12,900 19,000 18,000 66–70% 2.00 21.0 10.2 Variable R-410A US CA 17
160 MMCMRAQ18BA3Same as 38MGRBQ18BA3 Midea Mini-split 18,000 Btu (1.5-ton)12,900 19,000 18,000 66–70% 2.00 21.0 10.2 Variable R-410A US CA 3
161 D5CSRAH18AAK Airquest, Arcoaire + 10 more Mini-split 18,000 Btu (1.5-ton)13,000 18,000 18,000 70–77% 2.20 20.8 10.8 Variable R-454B US CA 89
162 25VNA448A*031* Carrier Central 42,000 Btu (3.5-ton)36,400 46,500 43,500 78% 2.26 20.8 9.0 Variable R-410A US CA 6
163 284ANV048*0**B* Bryant Central 42,000 Btu (3.5-ton)36,400 46,500 43,500 78% 2.26 20.8 9.0 Variable R-410A US CA 6
164 MOX430-18HFN10-M1P Midea Mini-split 18,000 Btu (1.5-ton)12,800 18,000 16,800 71% 2.20 20.7 11.3 Variable R-454B US CA 3
165 38MGHBQ36DA3 Bryant, Carrier + 3 more Mini-split 36,000 Btu (3-ton)34,400 37,000 36,000 89–97% 1.80 20.6 10.2 Variable R-410A US CA 15
166 MMCMHAQ36DA3Same as 38MGHBQ36DA3 Midea Mini-split 36,000 Btu (3-ton)34,400 37,000 36,000 89–97% 1.80 20.6 10.2 Variable R-410A US CA 3
167 37MAHAQ24AA3 Bryant, Carrier + 3 more Mini-split 24,000 Btu (2-ton)24,000 26,000 24,000 83–95% 2.18 20.5 11.7 Variable R-454B US CA 27
168 D5CSHAH24AAK Airquest, Arcoaire + 11 more Mini-split 24,000 Btu (2-ton)24,000 26,000 24,000 83–95% 2.18 20.5 11.7 Variable R-454B US CA 61
169 37MARAQ30AA3 Bryant, Carrier + 3 more Mini-split 30,000 Btu (2.5-ton)20,000 30,000 30,000 67–68% 2.03 20.5 9.5 Variable R-454B US CA 12
170 (C,H,T)5H3V48*K*AAA* Kenmore Central 42,000 Btu (3.5-ton)37,000 48,500 45,000 72–77% 1.93 20.5 9.0 Variable R-454B US CA 138
171 C5H3V48*K*AAA* Comfortmaker, Day & Night, Keeprite Central 42,000 Btu (3.5-ton)37,000 48,500 45,000 72–77% 1.93 20.5 9.0 Variable R-454B US CA 414
172 H5H3V48*K*AAA* ACiQ, Airquest + 2 more Central 42,000 Btu (3.5-ton)37,000 48,500 45,000 72–77% 1.94 20.5 9.0 Variable R-454B US CA 539
173 T5H3V48*K*AAA* Tempstar Central 42,000 Btu (3.5-ton)37,000 48,500 45,000 72–77% 1.93 20.5 9.0 Variable R-454B US CA 138
174 MO1BS-H30B-2A Midea Mini-split 30,000 Btu (2.5-ton)20,000 30,000 30,000 67–68% 2.03 20.5 9.0 Variable R-454B US CA 3
175 MOD30-30HFN1-MS0W MDV, Midea Mini-split 30,000 Btu (2.5-ton)17,500 30,000 30,000 58–61% 1.91 20.5 8.7 Variable R-410A US CA 4
176 27VNA336A*030* Carrier Central 36,000 Btu (3-ton)28,000 38,500 34,400 71–77% 2.02 20.5 8.5 Variable R-454B US CA 564
177 293VAN036**AA* Bryant Central 36,000 Btu (3-ton)28,000 38,500 34,400 71–77% 2.02 20.5 8.5 Variable R-454B US CA 564
178 (C,H,T)5H3V36*K*AAA* Kenmore Central 36,000 Btu (3-ton)28,000 37,400 35,200 71–77% 2.02 20.5 8.5 Variable R-454B US CA 564
179 B5H3V36*K*AAA* ACiQ, Airquest + 7 more Central 36,000 Btu (3-ton)28,000 38,500 34,400 71–77% 2.04 20.5 8.5 Variable R-454B US CA 4,626
180 C5H3V36*K*AAA* Comfortmaker, Day & Night, Keeprite Central 36,000 Btu (3-ton)28,000 37,400 35,200 71–77% 2.02 20.5 8.5 Variable R-454B US CA 1,692
181 H5H3V36*K*AAA* ACiQ, Airquest + 2 more Central 36,000 Btu (3-ton)28,000 37,400 35,200 71–77% 2.02 20.5 8.5 Variable R-454B US CA 2,256
182 T5H3V36*K*AAA* Tempstar Central 36,000 Btu (3-ton)28,000 37,400 35,200 71–77% 2.02 20.5 8.5 Variable R-454B US CA 564
183 MO1HS-H24B-2A Midea Mini-split 24,000 Btu (2-ton)24,000 26,000 24,000 83–95% 2.18 20.4 11.7 Variable R-454B US CA 5
184 37MHRAQ18AA3 Bryant, Carrier + 3 more Mini-split 18,000 Btu (1.5-ton)11,500 18,800 18,000 61% 2.00 20.3 9.1 Variable R-454B US CA 5
185 D5CERAH18AAK Airquest, Arcoaire + 9 more Mini-split 18,000 Btu (1.5-ton)11,500 18,800 18,000 61% 2.00 20.3 9.1 Variable R-454B US CA 11
186 37MAHAQ18AA3 Bryant, Carrier + 3 more Mini-split 18,000 Btu (1.5-ton)18,000 18,000 18,000 88–103% 1.92 20.2 11.0 Variable R-454B US CA 42
187 MO1BS-H18B-2A Midea Mini-split 18,000 Btu (1.5-ton)11,500 18,800 18,000 61% 2.00 20.2 9.1 Variable R-454B US CA 1
188 DLCSRBH30AAK11 Airquest, Arcoaire + 12 more Mini-split 30,000 Btu (2.5-ton)19,000 30,000 30,000 62–67% 1.85 20.1 8.7 Variable R-410A US CA 45
189 DLCSRBH30AAK Airquest, Arcoaire + 12 more Mini-split 30,000 Btu (2.5-ton)18,600 30,000 30,000 61–63% 1.89 20.1 8.7 Variable R-410A US CA 46
190 D5CSHAH18AAK Airquest, Arcoaire + 11 more Mini-split 18,000 Btu (1.5-ton)18,000 19,500 18,000 88–103% 1.95 20.0 10.8 Variable R-454B US CA 97
191 MO1HS-H18B-2A Midea Mini-split 18,000 Btu (1.5-ton)17,500 17,000 16,000 88–103% 1.94 20.0 10.8 Variable R-454B US CA 8
192 37MBRAQ36AA3 Bryant, Carrier + 3 more Mini-split 36,000 Btu (3-ton)26,600 38,000 36,000 70% 2.20 20.0 10.4 Variable R-454B US CA 5
193 D5CLRAH36AAK Airquest, Arcoaire + 9 more Mini-split 36,000 Btu (3-ton)26,600 38,000 36,000 70% 2.20 20.0 10.4 Variable R-454B US CA 11
194 MO1BU-H36B-2A Midea Mini-split 36,000 Btu (3-ton)26,600 38,000 36,000 70% 2.20 20.0 10.3 Variable R-454B US CA 1
195 MOD30-36HFN10-M2P Midea Mini-split 36,000 Btu (3-ton)26,600 38,000 36,000 70% 2.20 20.0 10.3 Variable R-454B US CA 1
196 DLCMRBH18BAK Airquest, Arcoaire + 10 more Mini-split 18,000 Btu (1.5-ton)12,900 19,000 18,000 66–70% 2.00 20.0 10.0 Variable R-410A US CA 42
197 DLCMRBH36DAK Airquest, Arcoaire + 10 more Mini-split 36,000 Btu (3-ton)24,000 37,000 36,000 65% 1.68 20.0 9.2 Variable R-410A US CA 12
198 XH960E2C11 Champion, Coleman + 4 more Central 48,000 Btu (4-ton)45,000 48,000 47,000 76–95% 2.00 20.0 8.5 Variable R-454B US CA 858
199 38MTRAQ27CA3 Bryant, Carrier + 3 more Mini-split 24,000 Btu (2-ton)16,400 27,000 27,000 61% 1.75 20.0 8.5 Variable R-410A US CA 5
200 DLCMTAH27CAKSame as 38MTRAQ27CA3 Airquest, Arcoaire + 10 more Mini-split 24,000 Btu (2-ton)16,400 27,000 27,000 61% 1.75 20.0 8.5 Variable R-410A US CA 12

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

200 of 710 units · page 1 of 4

Other sizes

Every size class, with how many units it holds and its median heat output at 5°F