Seattle City Light Heat Pump Rebates · page 5
Seattle City Light takes an instant discount off ducted heat pumps under 5.4 tons, by efficiency tier.
906 of the 1,183 certified central heat pumps in our data sold in the United States meet the published thresholds for $300–2,000 of Seattle City Light Heat Pump Rebates as of Sep 28, 2026.
The list
-
801 MOE30U-45HFN1-MAlsetria, Eco Air, MDV55,000 Btu/h16.12 kWheating at 47°F 45,000 Btu/h13.19 kWcooling at 95°F
-
802 5HCL6036A1000ATrane/American Standard40,000 Btu/h11.72 kWheating at 47°F 36,000 Btu/h10.55 kWcooling at 95°F
-
803 WSCHV0048BA1-CContinental47,000 Btu/h13.77 kWheating at 47°F 45,000 Btu/h13.19 kWcooling at 95°F
-
804 YDV36E2D11York34,000 Btu/h9.96 kWheating at 47°F 32,000 Btu/h9.38 kWcooling at 95°F
-
805 9SPV0-HP-X-DMulti MFG9,000 Btu/h2.64 kWheating at 47°F 9,000 Btu/h2.64 kWcooling at 95°F
-
806 A-KXP48TA-1Kerr48,000 Btu/h14.07 kWheating at 47°F 45,000 Btu/h13.19 kWcooling at 95°F
-
807 CCB1-H48A-OCapella48,000 Btu/h14.07 kWheating at 47°F 45,000 Btu/h13.19 kWcooling at 95°F
-
808 SOV48H2BAInnovair47,000 Btu/h13.77 kWheating at 47°F 45,000 Btu/h13.19 kWcooling at 95°F
-
809 AFE09N3H1Ephoca, Innova6,700 Btu/h1.96 kWheating at 47°F 6,700 Btu/h1.96 kWcooling at 95°F
-
810 YDC60E2D11York55,000 Btu/h16.12 kWheating at 47°F 52,000 Btu/h15.24 kWcooling at 95°F
-
811 RD16AY60AJVCFriedrich, Rheem + 3 more51,000 Btu/h14.95 kWheating at 47°F 51,000 Btu/h14.95 kWcooling at 95°F
-
812 AZPN/C36WDUIDKepler36,000 Btu/h10.55 kWheating at 47°F 35,000 Btu/h10.26 kWcooling at 95°F
-
813 DLCURAH36ACKMidea36,000 Btu/h10.55 kWheating at 47°F 35,000 Btu/h10.26 kWcooling at 95°F
-
814 MO1BE-H32B-2AMidea36,000 Btu/h10.55 kWheating at 47°F 32,000 Btu/h9.38 kWcooling at 95°F
-
815 MOD30-32HFN10-M3MDV36,000 Btu/h10.55 kWheating at 47°F 32,000 Btu/h9.38 kWcooling at 95°F
-
816 E4HL5024A1000AAmerican Standard, Ameristar + 2 more24,000 Btu/h7.03 kWheating at 47°F 24,000 Btu/h7.03 kWcooling at 95°F
-
817 THH24HAI2NAF2U23TCL24,000 Btu/h7.03 kWheating at 47°F 24,000 Btu/h7.03 kWcooling at 95°F
-
818 E4HL5018A1000AAmeristar, RunTru20,000 Btu/h5.86 kWheating at 47°F 20,000 Btu/h5.86 kWcooling at 95°F
-
819 THH18HAI2NAF2U23TCL20,000 Btu/h5.86 kWheating at 47°F 20,000 Btu/h5.86 kWcooling at 95°F
-
820 37MURAQ60AA3Bryant, Carrier + 3 more54,000 Btu/h15.83 kWheating at 47°F 54,000 Btu/h15.83 kWcooling at 95°F
-
821 ACIQ-60-EHPD1HVAC, ACiQ54,000 Btu/h15.83 kWheating at 47°F 54,000 Btu/h15.83 kWcooling at 95°F
-
822 AHU19-60HN1-CApooDr, AproDr54,000 Btu/h15.83 kWheating at 47°F 54,000 Btu/h15.83 kWcooling at 95°F
-
823 MO1AE-H48B-2AMidea48,000 Btu/h14.07 kWheating at 47°F 48,000 Btu/h14.07 kWcooling at 95°F
-
824 MOD30-48HFN10-M3FMDV48,000 Btu/h14.07 kWheating at 47°F 48,000 Btu/h14.07 kWcooling at 95°F
-
825 THH48HAI2NAF2U23TCL36,000 Btu/h10.55 kWheating at 47°F 36,000 Btu/h10.55 kWcooling at 95°F
-
826 BNG1A48SCNBlueridge48,000 Btu/h14.07 kWheating at 47°F 48,000 Btu/h14.07 kWcooling at 95°F
-
827 AC036FCUDCGSamsung36,000 Btu/h10.55 kWheating at 47°F 36,000 Btu/h10.55 kWcooling at 95°F
-
828 5HPL5048A1American Standard, Trane46,000 Btu/h13.48 kWheating at 47°F 41,000 Btu/h12.02 kWcooling at 95°F
-
829 THH48HES2NAGOH24TCL45,000 Btu/h13.19 kWheating at 47°F 41,000 Btu/h12.02 kWcooling at 95°F
-
830 AC048FCUDCGSamsung48,000 Btu/h14.07 kWheating at 47°F 47,000 Btu/h13.77 kWcooling at 95°F
-
831 FOP1560TJAZNAFujitsu56,500 Btu/h16.56 kWheating at 47°F 56,500 Btu/h16.56 kWcooling at 95°F
-
832 RP15AZ60AJ2NRheem, Ruud56,500 Btu/h16.56 kWheating at 47°F 56,500 Btu/h16.56 kWcooling at 95°F
-
833 E4HL5060A1000AAmeristar, RunTru45,000 Btu/h13.19 kWheating at 47°F 47,500 Btu/h13.92 kWcooling at 95°F
-
834 THH42HAI2NAF2U23TCL45,000 Btu/h13.19 kWheating at 47°F 48,000 Btu/h14.07 kWcooling at 95°F
-
835 THH60HAI2NAF2U23TCL45,000 Btu/h13.19 kWheating at 47°F 47,500 Btu/h13.92 kWcooling at 95°F
-
836 YH660E2S11York57,000 Btu/h16.71 kWheating at 47°F 54,000 Btu/h15.83 kWcooling at 95°F
-
837 RHP15060B21Evcon, Guardian57,000 Btu/h16.71 kWheating at 47°F 53,500 Btu/h15.68 kWcooling at 95°F
-
838 THF2B60T21Champion, Coleman + 3 more59,000 Btu/h17.29 kWheating at 47°F 55,500 Btu/h16.27 kWcooling at 95°F
-
839 YH2F60TB21York59,000 Btu/h17.29 kWheating at 47°F 55,500 Btu/h16.27 kWcooling at 95°F
-
840 FWP15AZ60AJ2NFriedrich57,000 Btu/h16.71 kWheating at 47°F 57,000 Btu/h16.71 kWcooling at 95°F
-
841 5HPL5036A1American Standard, Trane35,000 Btu/h10.26 kWheating at 47°F 33,000 Btu/h9.67 kWcooling at 95°F
-
842 5TWR5060A1Trane52,500 Btu/h15.39 kWheating at 47°F 54,500 Btu/h15.97 kWcooling at 95°F
-
843 5TWX5060A1Trane52,500 Btu/h15.39 kWheating at 47°F 55,000 Btu/h16.12 kWcooling at 95°F
-
844 A5HP5060A1Ameristar, RunTru53,000 Btu/h15.53 kWheating at 47°F 55,000 Btu/h16.12 kWcooling at 95°F
-
845 5TWR6060A1Trane52,500 Btu/h15.39 kWheating at 47°F 54,500 Btu/h15.97 kWcooling at 95°F
-
846 N5HP5060A1American Standard, Trane50,500 Btu/h14.80 kWheating at 47°F 54,500 Btu/h15.97 kWcooling at 95°F
-
847 ML17XP1-048-230ALennox45,000 Btu/h13.19 kWheating at 47°F 47,500 Btu/h13.92 kWcooling at 95°F
-
848 4HP17L48P-**AAC Pro, Allied + 4 more46,500 Btu/h13.63 kWheating at 47°F 48,000 Btu/h14.07 kWcooling at 95°F
-
849 BHP17L48P-**ABlueridge46,000 Btu/h13.48 kWheating at 47°F 48,000 Btu/h14.07 kWcooling at 95°F
-
850 MHP17048A-**AMRCOOL44,500 Btu/h13.04 kWheating at 47°F 47,000 Btu/h13.77 kWcooling at 95°F
-
851 NS17H48SA4-**AGE46,000 Btu/h13.48 kWheating at 47°F 48,000 Btu/h14.07 kWcooling at 95°F
-
852 YH2F48TB21York44,500 Btu/h13.04 kWheating at 47°F 46,000 Btu/h13.48 kWcooling at 95°F
-
853 RP15AZ48AJ2NRheem, Ruud45,000 Btu/h13.19 kWheating at 47°F 45,500 Btu/h13.33 kWcooling at 95°F
-
854 WP15AZ48AJ2NFujitsu, Rheem + 2 more45,000 Btu/h13.19 kWheating at 47°F 45,500 Btu/h13.33 kWcooling at 95°F
-
855 5DCZ5048A1American Standard, Trane42,500 Btu/h12.46 kWheating at 47°F 47,000 Btu/h13.77 kWcooling at 95°F
-
856 5TWR5048A1Trane43,000 Btu/h12.60 kWheating at 47°F 44,500 Btu/h13.04 kWcooling at 95°F
-
857 5TWR6048A1Trane43,000 Btu/h12.60 kWheating at 47°F 44,500 Btu/h13.04 kWcooling at 95°F
-
858 5TWX6048A1Trane42,500 Btu/h12.46 kWheating at 47°F 44,500 Btu/h13.04 kWcooling at 95°F
-
859 5WCZ5048A1American Standard, Trane42,000 Btu/h12.31 kWheating at 47°F 46,000 Btu/h13.48 kWcooling at 95°F
-
860 RHP15042B21Evcon, Guardian40,000 Btu/h11.72 kWheating at 47°F 41,000 Btu/h12.02 kWcooling at 95°F
-
861 YH2F42TB21York38,500 Btu/h11.28 kWheating at 47°F 40,500 Btu/h11.87 kWcooling at 95°F
-
862 FRP15AZ42AJ2NFriedrich39,500 Btu/h11.58 kWheating at 47°F 39,500 Btu/h11.58 kWcooling at 95°F
-
863 RP15AZ42AJ2NRheem, Ruud39,500 Btu/h11.58 kWheating at 47°F 40,000 Btu/h11.72 kWcooling at 95°F
-
864 WP15AZ42AJ2NFujitsu, Rheem + 2 more39,500 Btu/h11.58 kWheating at 47°F 40,000 Btu/h11.72 kWcooling at 95°F
-
865 RP14AZ36AJ2NRheem, Ruud34,200 Btu/h10.02 kWheating at 47°F 34,200 Btu/h10.02 kWcooling at 95°F
-
866 FWP15AZ36AJ2NFriedrich34,200 Btu/h10.02 kWheating at 47°F 34,200 Btu/h10.02 kWcooling at 95°F
-
867 THH30HAI2NAF2U23TCL24,000 Btu/h7.03 kWheating at 47°F 24,000 Btu/h7.03 kWcooling at 95°F
-
868 5HPL5024A1American Standard, Trane22,000 Btu/h6.45 kWheating at 47°F 21,000 Btu/h6.15 kWcooling at 95°F
-
869 TZP15AY42AJ2NThermal Zone40,000 Btu/h11.72 kWheating at 47°F 40,000 Btu/h11.72 kWcooling at 95°F
-
870 WP15AY42AJ2NFujitsu, Rheem + 2 more40,000 Btu/h11.72 kWheating at 47°F 40,000 Btu/h11.72 kWcooling at 95°F
-
871 E4HL5030A1000AAmeristar, RunTru25,000 Btu/h7.33 kWheating at 47°F 30,000 Btu/h8.79 kWcooling at 95°F
-
872 E4HL5036A1000AAmeristar, RunTru25,000 Btu/h7.33 kWheating at 47°F 30,000 Btu/h8.79 kWcooling at 95°F
-
873 THH36HAI2NAF2U23TCL25,000 Btu/h7.33 kWheating at 47°F 30,000 Btu/h8.79 kWcooling at 95°F
-
874 5DCZ5036A1American Standard, Trane33,800 Btu/h9.91 kWheating at 47°F 35,400 Btu/h10.37 kWcooling at 95°F
-
875 YH536E2S11York32,000 Btu/h9.38 kWheating at 47°F 33,800 Btu/h9.91 kWcooling at 95°F
-
876 A5HP5036A1Ameristar, RunTru31,400 Btu/h9.20 kWheating at 47°F 34,800 Btu/h10.20 kWcooling at 95°F
-
877 5TWR5036A1Trane31,000 Btu/h9.09 kWheating at 47°F 34,400 Btu/h10.08 kWcooling at 95°F
-
878 5TWR6036A1Trane31,400 Btu/h9.20 kWheating at 47°F 34,800 Btu/h10.20 kWcooling at 95°F
-
879 5TWX6036A1Trane31,400 Btu/h9.20 kWheating at 47°F 34,800 Btu/h10.20 kWcooling at 95°F
-
880 TZP15AZ30AJ2NThermal Zone28,400 Btu/h8.32 kWheating at 47°F 28,400 Btu/h8.32 kWcooling at 95°F
-
881 WP15AZ30AJ2NFujitsu, Rheem + 2 more28,400 Btu/h8.32 kWheating at 47°F 28,400 Btu/h8.32 kWcooling at 95°F
-
882 DRHP15A30AJ2ANDuraSTAR28,400 Btu/h8.32 kWheating at 47°F 28,400 Btu/h8.32 kWcooling at 95°F
-
883 FOP1530TJAZNAFujitsu28,400 Btu/h8.32 kWheating at 47°F 28,400 Btu/h8.32 kWcooling at 95°F
-
884 FWP15AZ30AJ2NFriedrich28,400 Btu/h8.32 kWheating at 47°F 28,400 Btu/h8.32 kWcooling at 95°F
-
885 MLP15AZ30AJ2NMainline28,400 Btu/h8.32 kWheating at 47°F 28,400 Btu/h8.32 kWcooling at 95°F
-
886 RP15AZ30AJ2NRheem, Ruud28,400 Btu/h8.32 kWheating at 47°F 28,400 Btu/h8.32 kWcooling at 95°F
-
887 SP15AZ30AJ2NRussell, Sure28,400 Btu/h8.32 kWheating at 47°F 28,400 Btu/h8.32 kWcooling at 95°F
-
888 RHP15030B21Evcon, Guardian28,400 Btu/h8.32 kWheating at 47°F 29,000 Btu/h8.50 kWcooling at 95°F
-
889 YH2F30TB21York28,800 Btu/h8.44 kWheating at 47°F 30,000 Btu/h8.79 kWcooling at 95°F
-
890 5TWR5030A1Trane25,600 Btu/h7.50 kWheating at 47°F 28,600 Btu/h8.38 kWcooling at 95°F
-
891 DRHP15A24AJ2ANDuraSTAR22,800 Btu/h6.68 kWheating at 47°F 22,800 Btu/h6.68 kWcooling at 95°F
-
892 MPP15AZ24AJ2NMainline22,800 Btu/h6.68 kWheating at 47°F 22,800 Btu/h6.68 kWcooling at 95°F
-
893 SP15AZ24AJ2NRussell, Sure22,800 Btu/h6.68 kWheating at 47°F 22,800 Btu/h6.68 kWcooling at 95°F
-
894 TZP15AZ24AJ2NThermal Zone22,800 Btu/h6.68 kWheating at 47°F 22,800 Btu/h6.68 kWcooling at 95°F
-
895 TZPLAD1524AJNThermal Zone22,800 Btu/h6.68 kWheating at 47°F 22,800 Btu/h6.68 kWcooling at 95°F
-
896 FOP1524TJAZNAFujitsu22,800 Btu/h6.68 kWheating at 47°F 22,800 Btu/h6.68 kWcooling at 95°F
-
897 WP15AZ24AJ2NFujitsu, Rheem + 2 more22,800 Btu/h6.68 kWheating at 47°F 22,800 Btu/h6.68 kWcooling at 95°F
-
898 YH524E2S11York22,800 Btu/h6.68 kWheating at 47°F 24,000 Btu/h7.03 kWcooling at 95°F
-
899 RP15AZ24AJ2NRheem, Ruud22,800 Btu/h6.68 kWheating at 47°F 22,800 Btu/h6.68 kWcooling at 95°F
-
900 YH2F24TB21York21,600 Btu/h6.33 kWheating at 47°F 23,400 Btu/h6.86 kWcooling at 95°F
-
901 FRP15AZ18AJ2NFriedrich17,100 Btu/h5.01 kWheating at 47°F 17,100 Btu/h5.01 kWcooling at 95°F
-
902 5TWR6018A1Trane17,500 Btu/h5.13 kWheating at 47°F 18,000 Btu/h5.28 kWcooling at 95°F
-
903 5TWX6018A1Trane17,600 Btu/h5.16 kWheating at 47°F 18,000 Btu/h5.28 kWcooling at 95°F
-
904 MLP15AY18AJ2NMainline17,100 Btu/h5.01 kWheating at 47°F 17,100 Btu/h5.01 kWcooling at 95°F
-
905 W4H5S60*K*AAA*EcoTemp, Grandaire56,000 Btu/h16.41 kWheating at 47°F 57,000 Btu/h16.71 kWcooling at 95°F
-
906 W4H7T36*K*AAA*EcoTemp, Grandaire34,600 Btu/h10.14 kWheating at 47°F 33,200 Btu/h9.73 kWcooling at 95°F
| # | Model | Brands | Type | Size | At 5°FBtu/hkW · heating | At 47°FBtu/hkW · heating | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | SEER2median pairing | HSPF2Btu/Wh · median pairing | Compressor | Refrigerant | Market | Pairings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 801 | MOE30U-45HFN1-M | Alsetria, Eco Air, MDV | Central | 42,000 Btu (3.5-ton) | 46,50013.63 | 55,00016.12 | 45,00013.19 | 85% | 1.80 | 15.2 | 9.2 | Variable | R-410A | US CA | 3 |
| 802 | 5HCL6036A1000A | Trane/American Standard | Central | 36,000 Btu (3-ton) | 37,00010.84 | 40,00011.72 | 36,00010.55 | 93% | 1.80 | 15.2 | 9.1 | Variable | R-454B | US | 1 |
| 803 | WSCHV0048BA1-C | Continental | Central | 42,000 Btu (3.5-ton) | 40,00011.72 | 47,00013.77 | 45,00013.19 | 85% | 1.85 | 15.2 | 9.0 | Variable | R-454B | US CA | 1 |
| 804 | YDV36E2D11 | York | Central | 24,000 Btu (2-ton) | 23,8006.98 | 34,0009.96 | 32,0009.38 | 70–73% | 1.90 | 15.2 | 9.0 | Variable | R-454B | US CA | 7 |
| 805 | 9SPV0-HP-X-D | Multi MFG | Central | 9,000 Btu | 8,0002.34 | 9,0002.64 | 9,0002.64 | 89% | 2.30 | 15.2 | 8.9 | Variable | R-454B | US | 1 |
| 806 | A-KXP48TA-1 | Kerr | Central | 42,000 Btu (3.5-ton) | 42,00012.31 | 48,00014.07 | 45,00013.19 | 88% | 1.85 | 15.2 | 8.8 | Variable | R-454B | US CA | 1 |
| 807 | CCB1-H48A-O | Capella | Central | 42,000 Btu (3.5-ton) | 42,00012.31 | 48,00014.07 | 45,00013.19 | 88–92% | 1.85 | 15.2 | 8.8 | Variable | R-454B | US CA | 3 |
| 808 | SOV48H2BA | Innovair | Central | 42,000 Btu (3.5-ton) | 40,00011.72 | 47,00013.77 | 45,00013.19 | 79–93% | 1.83 | 15.2 | 8.8 | Variable | R-454B | US CA | 4 |
| 809 | AFE09N3H1 | Ephoca, Innova | Central | 6,000 Btu | 4,5001.32 | 6,7001.96 | 6,7001.96 | 67% | 1.77 | 15.2 | 8.6 | Variable | R-32 | US CA | 2 |
| 810 | YDC60E2D11 | York | Central | 42,000 Btu (3.5-ton) | 47,00013.77 | 55,00016.12 | 52,00015.24 | 85–100% | 1.80 | 15.2 | 8.5 | Variable | R-454B | US CA | 7 |
| 811 | RD16AY60AJVC | Friedrich, Rheem + 3 more | Central | 48,000 Btu (4-ton) | 31,0009.09 | 51,00014.95 | 51,00014.95 | 53–61% | 2.20 | 15.2 | 8.5 | Variable | R-454B | US CA | 23 |
| 812 | AZPN/C36WDUID | Kepler | Central | 36,000 Btu (3-ton) | 30,0008.79 | 36,00010.55 | 35,00010.26 | 83% | 1.80 | 15.2 | 8.5 | Variable | R-410A | US CA | 1 |
| 813 | DLCURAH36ACK | Midea | Central | 36,000 Btu (3-ton) | 30,0008.79 | 36,00010.55 | 35,00010.26 | 83–97% | 1.80 | 15.2 | 8.5 | Variable | R-410A | US CA | 3 |
| 814 | MO1BE-H32B-2A | Midea | Central | 30,000 Btu (2.5-ton) | 26,4007.74 | 36,00010.55 | 32,0009.38 | 73–75% | 2.00 | 15.2 | 8.5 | Variable | R-454B | US CA | 5 |
| 815 | MOD30-32HFN10-M3 | MDV | Central | 30,000 Btu (2.5-ton) | 26,4007.74 | 36,00010.55 | 32,0009.38 | 73% | 2.00 | 15.2 | 8.5 | Variable | R-454B | US CA | 2 |
| 816 | E4HL5024A1000A | American Standard, Ameristar + 2 more | Central | 24,000 Btu (2-ton) | 21,0006.15 | 24,0007.03 | 24,0007.03 | 71–88% | 1.85 | 15.2 | 8.5 | Variable | R-410A | US CA | 10 |
| 817 | THH24HAI2NAF2U23 | TCL | Central | 24,000 Btu (2-ton) | 21,0006.15 | 24,0007.03 | 24,0007.03 | 71–88% | 1.85 | 15.2 | 8.5 | Variable | R-410A | US CA | 12 |
| 818 | E4HL5018A1000A | Ameristar, RunTru | Central | 18,000 Btu (1.5-ton) | 18,0005.28 | 20,0005.86 | 20,0005.86 | 90% | 1.85 | 15.2 | 8.5 | Variable | R-410A | US CA | 4 |
| 819 | THH18HAI2NAF2U23 | TCL | Central | 18,000 Btu (1.5-ton) | 18,0005.28 | 20,0005.86 | 20,0005.86 | 89–90% | 1.85 | 15.2 | 8.5 | Variable | R-410A | US CA | 7 |
| 820 | 37MURAQ60AA3 | Bryant, Carrier + 3 more | Central | 54,000 Btu (4.5-ton) | 38,00011.14 | 54,00015.83 | 54,00015.83 | 70% | 1.80 | 15.2 | 8.4 | Variable | R-454B | US CA | 5 |
| 821 | ACIQ-60-EHPD | 1HVAC, ACiQ | Central | 54,000 Btu (4.5-ton) | 38,00011.14 | 54,00015.83 | 54,00015.83 | 70% | 1.80 | 15.2 | 8.4 | Variable | R-454B | US CA | 2 |
| 822 | AHU19-60HN1-C | ApooDr, AproDr | Central | 54,000 Btu (4.5-ton) | 38,00011.14 | 54,00015.83 | 54,00015.83 | 70% | 1.80 | 15.2 | 8.4 | Variable | R-454B | US CA | 2 |
| 823 | MO1AE-H48B-2A | Midea | Central | 48,000 Btu (4-ton) | 33,6009.85 | 48,00014.07 | 48,00014.07 | 70% | 1.85 | 15.2 | 8.4 | Variable | R-454B | US CA | 2 |
| 824 | MOD30-48HFN10-M3F | MDV | Central | 48,000 Btu (4-ton) | 33,6009.85 | 48,00014.07 | 48,00014.07 | 70% | 1.85 | 15.2 | 8.3 | Variable | R-454B | US CA | 4 |
| 825 | THH48HAI2NAF2U23 | TCL | Central | 36,000 Btu (3-ton) | 30,0008.79 | 36,00010.55 | 36,00010.55 | 71–83% | 1.78 | 15.2 | 8.3 | Variable | R-410A | US CA | 2 |
| 826 | BNG1A48SCN | Blueridge | Central | 48,000 Btu (4-ton) | 33,6009.85 | 48,00014.07 | 48,00014.07 | 70% | 1.85 | 15.2 | 8.2 | Variable | R-454B | US CA | 1 |
| 827 | AC036FCUDCG | Samsung | Central | 36,000 Btu (3-ton) | 26,2007.68 | 36,00010.55 | 36,00010.55 | 73–74% | 1.88 | 15.2 | 8.2 | 2-stage | R-454B | US CA | 2 |
| 828 | 5HPL5048A1 | American Standard, Trane | Central | 42,000 Btu (3.5-ton) | 37,00010.84 | 46,00013.48 | 41,00012.02 | 79–80% | 1.80 | 15.2 | 8.1 | 2-stage | R-454B | US CA | 8 |
| 829 | THH48HES2NAGOH24 | TCL | Central | 42,000 Btu (3.5-ton) | 37,00010.84 | 45,00013.19 | 41,00012.02 | 79–82% | 1.80 | 15.2 | 8.1 | 2-stage | R-454B | US CA | 22 |
| 830 | AC048FCUDCG | Samsung | Central | 48,000 Btu (4-ton) | 34,60010.14 | 48,00014.07 | 47,00013.77 | 72–80% | 1.91 | 15.2 | 8.1 | 2-stage | R-454B | US CA | 2 |
| 831 | FOP1560TJAZNA | Fujitsu | Central | 54,000 Btu (4.5-ton) | 33,6009.85 | 56,50016.56 | 56,50016.56 | 54–61% | 2.50 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 4 |
| 832 | RP15AZ60AJ2N | Rheem, Ruud | Central | 54,000 Btu (4.5-ton) | 33,6009.85 | 56,50016.56 | 56,50016.56 | 54–61% | 2.50 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 12 |
| 833 | E4HL5060A1000A | Ameristar, RunTru | Central | 48,000 Btu (4-ton) | 33,4009.79 | 45,00013.19 | 47,50013.92 | 74% | 1.75 | 15.2 | 8.1 | Variable | R-410A | US CA | 2 |
| 834 | THH42HAI2NAF2U23 | TCL | Central | 36,000 Btu (3-ton) | 33,4009.79 | 45,00013.19 | 48,00014.07 | 74–83% | 1.75 | 15.2 | 8.1 | Variable | R-410A | US CA | 3 |
| 835 | THH60HAI2NAF2U23 | TCL | Central | 48,000 Btu (4-ton) | 33,4009.79 | 45,00013.19 | 47,50013.92 | 70–74% | 1.75 | 15.2 | 8.1 | Variable | R-410A | US CA | 6 |
| 836 | YH660E2S11 | York | Central | 54,000 Btu (4.5-ton) | 31,4009.20 | 57,00016.71 | 54,00015.83 | 52–56% | 2.26 | 15.2 | 8.1 | 2-stage | R-454B | US CA | 235 |
| 837 | RHP15060B21 | Evcon, Guardian | Central | 54,000 Btu (4.5-ton) | 31,2009.14 | 57,00016.71 | 53,50015.68 | 53–57% | 2.34 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 38 |
| 838 | THF2B60T21 | Champion, Coleman + 3 more | Central | 54,000 Btu (4.5-ton) | 31,2009.14 | 59,00017.29 | 55,50016.27 | 50–57% | 2.32 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 937 |
| 839 | YH2F60TB21 | York | Central | 54,000 Btu (4.5-ton) | 31,2009.14 | 59,00017.29 | 55,50016.27 | 50–57% | 2.26 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 177 |
| 840 | FWP15AZ60AJ2N | Friedrich | Central | 54,000 Btu (4.5-ton) | 30,6008.97 | 57,00016.71 | 57,00016.71 | 52–60% | 2.45 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 4 |
| 841 | 5HPL5036A1 | American Standard, Trane | Central | 30,000 Btu (2.5-ton) | 30,0008.79 | 35,00010.26 | 33,0009.67 | 79–86% | 1.80 | 15.2 | 8.1 | 2-stage | R-454B | US CA | 44 |
| 842 | 5TWR5060A1 | Trane | Central | 54,000 Btu (4.5-ton) | 28,2008.26 | 52,50015.39 | 54,50015.97 | 52–54% | 2.35 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 6 |
| 843 | 5TWX5060A1 | Trane | Central | 54,000 Btu (4.5-ton) | 28,2008.26 | 52,50015.39 | 55,00016.12 | 54% | 2.40 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 1 |
| 844 | A5HP5060A1 | Ameristar, RunTru | Central | 54,000 Btu (4.5-ton) | 28,2008.26 | 53,00015.53 | 55,00016.12 | 53% | 2.30 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 7 |
| 845 | 5TWR6060A1 | Trane | Central | 54,000 Btu (4.5-ton) | 27,8008.15 | 52,50015.39 | 54,50015.97 | 52–54% | 2.49 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 4 |
| 846 | N5HP5060A1 | American Standard, Trane | Central | 54,000 Btu (4.5-ton) | 27,8008.15 | 50,50014.80 | 54,50015.97 | 55% | 2.45 | 15.2 | 8.1 | 1-stage | R-454B | US | 6 |
| 847 | ML17XP1-048-230A | Lennox | Central | 48,000 Btu (4-ton) | 25,4007.44 | 45,00013.19 | 47,50013.92 | 53–57% | 2.26 | 15.2 | 8.1 | 1-stage | R-410A | US CA | 303 |
| 848 | 4HP17L48P-**A | AC Pro, Allied + 4 more | Central | 48,000 Btu (4-ton) | 25,2007.39 | 46,50013.63 | 48,00014.07 | 53–57% | 2.26 | 15.2 | 8.1 | 1-stage | R-410A | US CA | 803 |
| 849 | BHP17L48P-**A | Blueridge | Central | 48,000 Btu (4-ton) | 25,2007.39 | 46,00013.48 | 48,00014.07 | 53–57% | 2.26 | 15.2 | 8.1 | 1-stage | R-410A | US CA | 85 |
| 850 | MHP17048A-**A | MRCOOL | Central | 48,000 Btu (4-ton) | 25,2007.39 | 44,50013.04 | 47,00013.77 | 54–57% | 2.26 | 15.2 | 8.1 | 1-stage | R-410A | US CA | 19 |
| 851 | NS17H48SA4-**A | GE | Central | 48,000 Btu (4-ton) | 25,2007.39 | 46,00013.48 | 48,00014.07 | 53–57% | 2.26 | 15.2 | 8.1 | 1-stage | R-410A | US CA | 134 |
| 852 | YH2F48TB21 | York | Central | 48,000 Btu (4-ton) | 25,0007.33 | 44,50013.04 | 46,00013.48 | 53–66% | 2.40 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 327 |
| 853 | RP15AZ48AJ2N | Rheem, Ruud | Central | 48,000 Btu (4-ton) | 24,2007.09 | 45,00013.19 | 45,50013.33 | 54–60% | 2.35 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 4 |
| 854 | WP15AZ48AJ2N | Fujitsu, Rheem + 2 more | Central | 48,000 Btu (4-ton) | 24,2007.09 | 45,00013.19 | 45,50013.33 | 54% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 10 |
| 855 | 5DCZ5048A1 | American Standard, Trane | Central | 48,000 Btu (4-ton) | 22,0006.45 | 42,50012.46 | 47,00013.77 | 52% | 2.00 | 15.2 | 8.1 | 2-stage | R-454B | US | 2 |
| 856 | 5TWR5048A1 | Trane | Central | 42,000 Btu (3.5-ton) | 22,0006.45 | 43,00012.60 | 44,50013.04 | 50–53% | 2.10 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 167 |
| 857 | 5TWR6048A1 | Trane | Central | 42,000 Btu (3.5-ton) | 22,0006.45 | 43,00012.60 | 44,50013.04 | 50–53% | 2.18 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 127 |
| 858 | 5TWX6048A1 | Trane | Central | 42,000 Btu (3.5-ton) | 22,0006.45 | 42,50012.46 | 44,50013.04 | 50–53% | 2.18 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 54 |
| 859 | 5WCZ5048A1 | American Standard, Trane | Central | 48,000 Btu (4-ton) | 22,0006.45 | 42,00012.31 | 46,00013.48 | 52% | 2.00 | 15.2 | 8.1 | 2-stage | R-454B | US | 2 |
| 860 | RHP15042B21 | Evcon, Guardian | Central | 42,000 Btu (3.5-ton) | 20,8006.10 | 40,00011.72 | 41,00012.02 | 47–56% | 2.22 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 54 |
| 861 | YH2F42TB21 | York | Central | 42,000 Btu (3.5-ton) | 20,8006.10 | 38,50011.28 | 40,50011.87 | 46–57% | 2.22 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 449 |
| 862 | FRP15AZ42AJ2N | Friedrich | Central | 42,000 Btu (3.5-ton) | 20,4005.98 | 39,50011.58 | 39,50011.58 | 52–58% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 10 |
| 863 | RP15AZ42AJ2N | Rheem, Ruud | Central | 42,000 Btu (3.5-ton) | 20,4005.98 | 39,50011.58 | 40,00011.72 | 52–57% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 6 |
| 864 | WP15AZ42AJ2N | Fujitsu, Rheem + 2 more | Central | 42,000 Btu (3.5-ton) | 20,4005.98 | 39,50011.58 | 40,00011.72 | 52% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 10 |
| 865 | RP14AZ36AJ2N | Rheem, Ruud | Central | 36,000 Btu (3-ton) | 20,2005.92 | 34,20010.02 | 34,20010.02 | 59% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 2 |
| 866 | FWP15AZ36AJ2N | Friedrich | Central | 36,000 Btu (3-ton) | 19,7005.77 | 34,20010.02 | 34,20010.02 | 51–58% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 38 |
| 867 | THH30HAI2NAF2U23 | TCL | Central | 30,000 Btu (2.5-ton) | 19,5005.71 | 24,0007.03 | 24,0007.03 | 72–81% | 1.75 | 15.2 | 8.1 | Variable | R-410A | US CA | 5 |
| 868 | 5HPL5024A1 | American Standard, Trane | Central | 18,000 Btu (1.5-ton) | 19,0005.57 | 22,0006.45 | 21,0006.15 | 78–90% | 1.80 | 15.2 | 8.1 | 2-stage | R-454B | US CA | 60 |
| 869 | TZP15AY42AJ2N | Thermal Zone | Central | 42,000 Btu (3.5-ton) | 18,9005.54 | 40,00011.72 | 40,00011.72 | 47–48% | 2.00 | 15.2 | 8.1 | 2-stage | R-454B | US | 56 |
| 870 | WP15AY42AJ2N | Fujitsu, Rheem + 2 more | Central | 42,000 Btu (3.5-ton) | 18,9005.54 | 40,00011.72 | 40,00011.72 | 46–53% | 2.00 | 15.2 | 8.1 | 2-stage | R-454B | US CA | 328 |
| 871 | E4HL5030A1000A | Ameristar, RunTru | Central | 30,000 Btu (2.5-ton) | 18,0005.28 | 25,0007.33 | 30,0008.79 | 72% | 1.75 | 15.2 | 8.1 | Variable | R-410A | US CA | 2 |
| 872 | E4HL5036A1000A | Ameristar, RunTru | Central | 30,000 Btu (2.5-ton) | 18,0005.28 | 25,0007.33 | 30,0008.79 | 70–72% | 1.75 | 15.2 | 8.1 | Variable | R-410A | US CA | 12 |
| 873 | THH36HAI2NAF2U23 | TCL | Central | 30,000 Btu (2.5-ton) | 18,0005.28 | 25,0007.33 | 30,0008.79 | 70–75% | 1.75 | 15.2 | 8.1 | Variable | R-410A | US CA | 15 |
| 874 | 5DCZ5036A1 | American Standard, Trane | Central | 36,000 Btu (3-ton) | 17,6005.16 | 33,8009.91 | 35,40010.37 | 52% | 2.00 | 15.2 | 8.1 | 2-stage | R-454B | US | 2 |
| 875 | YH536E2S11 | York | Central | 36,000 Btu (3-ton) | 17,6005.16 | 32,0009.38 | 33,8009.91 | 53–59% | 2.00 | 15.2 | 8.1 | 2-stage | R-454B | US CA | 304 |
| 876 | A5HP5036A1 | Ameristar, RunTru | Central | 36,000 Btu (3-ton) | 17,4005.10 | 31,4009.20 | 34,80010.20 | 54–57% | 2.20 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 296 |
| 877 | 5TWR5036A1 | Trane | Central | 36,000 Btu (3-ton) | 17,3005.07 | 31,0009.09 | 34,40010.08 | 53–57% | 2.30 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 481 |
| 878 | 5TWR6036A1 | Trane | Central | 36,000 Btu (3-ton) | 17,2005.04 | 31,4009.20 | 34,80010.20 | 53–58% | 2.36 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 371 |
| 879 | 5TWX6036A1 | Trane | Central | 36,000 Btu (3-ton) | 17,2005.04 | 31,4009.20 | 34,80010.20 | 53–58% | 2.35 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 374 |
| 880 | TZP15AZ30AJ2N | Thermal Zone | Central | 30,000 Btu (2.5-ton) | 16,0004.69 | 28,4008.32 | 28,4008.32 | 55–57% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 7 |
| 881 | WP15AZ30AJ2N | Fujitsu, Rheem + 2 more | Central | 30,000 Btu (2.5-ton) | 16,0004.69 | 28,4008.32 | 28,4008.32 | 50–57% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 82 |
| 882 | DRHP15A30AJ2AN | DuraSTAR | Central | 30,000 Btu (2.5-ton) | 15,9004.66 | 28,4008.32 | 28,4008.32 | 50–57% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 8 |
| 883 | FOP1530TJAZNA | Fujitsu | Central | 30,000 Btu (2.5-ton) | 15,9004.66 | 28,4008.32 | 28,4008.32 | 50–57% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 10 |
| 884 | FWP15AZ30AJ2N | Friedrich | Central | 30,000 Btu (2.5-ton) | 15,9004.66 | 28,4008.32 | 28,4008.32 | 50–57% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 90 |
| 885 | MLP15AZ30AJ2N | Mainline | Central | 30,000 Btu (2.5-ton) | 15,9004.66 | 28,4008.32 | 28,4008.32 | 55–57% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 10 |
| 886 | RP15AZ30AJ2N | Rheem, Ruud | Central | 30,000 Btu (2.5-ton) | 15,9004.66 | 28,4008.32 | 28,4008.32 | 50–57% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 52 |
| 887 | SP15AZ30AJ2N | Russell, Sure | Central | 30,000 Btu (2.5-ton) | 15,9004.66 | 28,4008.32 | 28,4008.32 | 51–57% | 2.10 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 49 |
| 888 | RHP15030B21 | Evcon, Guardian | Central | 30,000 Btu (2.5-ton) | 15,8004.63 | 28,4008.32 | 29,0008.50 | 54–65% | 2.40 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 20 |
| 889 | YH2F30TB21 | York | Central | 30,000 Btu (2.5-ton) | 14,5004.25 | 28,8008.44 | 30,0008.79 | 49–65% | 2.12 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 188 |
| 890 | 5TWR5030A1 | Trane | Central | 30,000 Btu (2.5-ton) | 13,4003.93 | 25,6007.50 | 28,6008.38 | 51–53% | 2.10 | 15.2 | 8.1 | 1-stage | R-454B | US CA | 140 |
| 891 | DRHP15A24AJ2AN | DuraSTAR | Central | 24,000 Btu (2-ton) | 12,6003.69 | 22,8006.68 | 22,8006.68 | 51–56% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 9 |
| 892 | MPP15AZ24AJ2N | Mainline | Central | 24,000 Btu (2-ton) | 12,6003.69 | 22,8006.68 | 22,8006.68 | 52–56% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 8 |
| 893 | SP15AZ24AJ2N | Russell, Sure | Central | 24,000 Btu (2-ton) | 12,6003.69 | 22,8006.68 | 22,8006.68 | 52–63% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 36 |
| 894 | TZP15AZ24AJ2N | Thermal Zone | Central | 24,000 Btu (2-ton) | 12,6003.69 | 22,8006.68 | 22,8006.68 | 52–55% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 6 |
| 895 | TZPLAD1524AJN | Thermal Zone | Central | 24,000 Btu (2-ton) | 12,6003.69 | 22,8006.68 | 22,8006.68 | 52–55% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 7 |
| 896 | FOP1524TJAZNA | Fujitsu | Central | 24,000 Btu (2-ton) | 12,5003.66 | 22,8006.68 | 22,8006.68 | 52–56% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 12 |
| 897 | WP15AZ24AJ2N | Fujitsu, Rheem + 2 more | Central | 24,000 Btu (2-ton) | 12,5003.66 | 22,8006.68 | 22,8006.68 | 51–63% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 78 |
| 898 | YH524E2S11 | York | Central | 24,000 Btu (2-ton) | 12,4003.63 | 22,8006.68 | 24,0007.03 | 49–55% | 2.24 | 15.2 | 8.1 | 2-stage | R-454B | US CA | 55 |
| 899 | RP15AZ24AJ2N | Rheem, Ruud | Central | 24,000 Btu (2-ton) | 12,3003.60 | 22,8006.68 | 22,8006.68 | 51–63% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 48 |
| 900 | YH2F24TB21 | York | Central | 24,000 Btu (2-ton) | 11,1003.25 | 21,6006.33 | 23,4006.86 | 43–54% | 2.16 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 119 |
| 901 | FRP15AZ18AJ2N | Friedrich | Central | 18,000 Btu (1.5-ton) | 9,3002.73 | 17,1005.01 | 17,1005.01 | 47–56% | 2.20 | 15.2 | 8.1 | 2-stage | R-410A | US CA | 42 |
| 902 | 5TWR6018A1 | Trane | Central | 18,000 Btu (1.5-ton) | 8,8002.58 | 17,5005.13 | 18,0005.28 | 48–50% | 2.09 | 15.2 | 8.1 | 1-stage | R-454B | US | 6 |
| 903 | 5TWX6018A1 | Trane | Central | 18,000 Btu (1.5-ton) | 8,8002.58 | 17,6005.16 | 18,0005.28 | 48–50% | 2.08 | 15.2 | 8.1 | 1-stage | R-454B | US | 6 |
| 904 | MLP15AY18AJ2N | Mainline | Central | 18,000 Btu (1.5-ton) | 8,6002.52 | 17,1005.01 | 17,1005.01 | 50% | 2.00 | 15.2 | 8.1 | 2-stage | R-454B | US | 1 |
| 905 | W4H5S60*K*AAA* | EcoTemp, Grandaire | Central | 54,000 Btu (4.5-ton) | —— | 56,00016.41 | 57,00016.71 | — | — | 15.2 | 8.1 | 1-stage | R-410A | US CA | 2 |
| 906 | W4H7T36*K*AAA* | EcoTemp, Grandaire | Central | 36,000 Btu (3-ton) | —— | 34,60010.14 | 33,2009.73 | — | — | 15.2 | 8.1 | 2-stage | R-410A | US CA | 2 |
106 of 906 units · page 5 of 5
Program specifications
| Tier 1 | $300 per system |
|---|---|
| Tier 2 | $400 per system |
| Tier 3 | $600 per system |
| Oil to electric conversion | $2,000 per system |
| Region | Washington, United States |
| Status | Open |
| Program page | The program's own page |
| Checked | Sep 28, 2026 |
Efficiency thresholds
| Requirement | Central only |
|---|---|
| SEER2median certified pairing | 15.2 or more |
| HSPF2median certified pairing | 8.1 or more |
The tier 1 figures.
Other programs in Washington
Excluded from this program
The program also requires purchase through participating distributors and contractors and a system under 5.4 tons. The unit list does not check these.